Free‐Breathing 3D Cardiac MRI Using Iterative Image‐Based Respiratory Motion Correction

Respiratory motion compensation using diaphragmatic navigator gating with a 5 mm gating window is conventionally used for free‐breathing cardiac MRI. Because of the narrow gating window, scan efficiency is low resulting in long scan times, especially for patients with irregular breathing patterns. In this work, a new retrospective motion compensation algorithm is presented to reduce the scan time for free‐breathing cardiac MRI that increasing the gating window to 15 mm without compromising image quality. The proposed algorithm iteratively corrects for respiratory‐induced cardiac motion by optimizing the sharpness of the heart. To evaluate this technique, two coronary MRI datasets with 1.3 mm3 resolution were acquired from 11 healthy subjects (seven females, 25 ± 9 years); one using a navigator with a 5 mm gating window acquired in 12.0 ± 2.0 min and one with a 15 mm gating window acquired in 7.1 ± 1.0 min. The images acquired with a 15 mm gating window were corrected using the proposed algorithm and compared to the uncorrected images acquired with the 5 and 15 mm gating windows. The image quality score, sharpness, and length of the three major coronary arteries were equivalent between the corrected images and the images acquired with a 5 mm gating window (P‐value > 0.05), while the scan time was reduced by a factor of 1.7. Magn Reson Med, 70:1005–1015, 2013. © 2012 Wiley Periodicals, Inc.

[1]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[2]  Debiao Li,et al.  A dual‐projection respiratory self‐gating technique for whole‐heart coronary MRA , 2008, Journal of magnetic resonance imaging : JMRI.

[3]  Andrew C Larson,et al.  Self‐gated cardiac cine MRI , 2004, Magnetic resonance in medicine.

[4]  Reza Nezafat,et al.  Motion correction using coil arrays (MOCCA) for free‐breathing cardiac cine MRI , 2011, Magnetic resonance in medicine.

[5]  David Atkinson,et al.  A study of the motion and deformation of the heart due to respiration , 2002, IEEE Transactions on Medical Imaging.

[6]  René M. Botnar,et al.  Impact of navigator timing on free‐breathing submillimeter 3D coronary magnetic resonance angiography , 2002, Magnetic resonance in medicine.

[7]  Peter Boesiger,et al.  Nonrigid retrospective respiratory motion correction in whole‐heart coronary MRA , 2011, Magnetic resonance in medicine.

[8]  Andrew C Larson,et al.  Preliminary investigation of respiratory self‐gating for free‐breathing segmented cine MRI , 2005, Magnetic resonance in medicine.

[9]  Warren J Manning,et al.  Coronary MRI: more pretty pictures or present-day value? , 2006, Journal of the American College of Cardiology.

[10]  Use of respiratory biofeedback and CLAWS for increased navigator efficiency for imaging the thoracic aorta , 2011, Magnetic resonance in medicine.

[11]  D. Firmin,et al.  Motion in cardiovascular MR imaging. , 2009, Radiology.

[12]  Elliot R. McVeigh,et al.  Displacement and velocity of the coronary arteries: cardiac and respiratory motion , 2006, IEEE Transactions on Medical Imaging.

[13]  K. Katahira,et al.  Assessment of coronary artery disease using magnetic resonance coronary angiography: a national multicenter trial. , 2010, Journal of the American College of Cardiology.

[14]  Vahid Tarokh,et al.  Low‐dimensional‐structure self‐learning and thresholding: Regularization beyond compressed sensing for MRI Reconstruction , 2011, Magnetic resonance in medicine.

[15]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[16]  P. Börnert,et al.  Free‐breathing whole‐heart coronary MRA with 3D radial SSFP and self‐navigated image reconstruction , 2005, Magnetic resonance in medicine.

[17]  Markus Henningsson,et al.  Whole‐heart coronary MR angiography with 2D self‐navigated image reconstruction , 2012, Magnetic resonance in medicine.

[18]  J Felblinger,et al.  Synchronization device for electrocardiography-gated echo-planar imaging. , 1995, Radiology.

[19]  J Keegan,et al.  3D coronary artery imaging with phase reordering for improved scan efficiency , 1999, Magnetic resonance in medicine.

[20]  René M. Botnar,et al.  “Soap‐Bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiograms , 2002, Magnetic resonance in medicine.

[21]  M Weiger,et al.  Motion‐adapted gating based on k‐space weighting for reduction of respiratory motion artifacts , 1997, Magnetic resonance in medicine.

[22]  Debiao Li,et al.  Respiratory self‐gated four‐dimensional coronary MR angiography: A feasibility study , 2008, Magnetic resonance in medicine.

[23]  Kay Nehrke,et al.  Improved bulk myocardial motion suppression for navigator‐gated coronary magnetic resonance imaging , 2007, Journal of magnetic resonance imaging : JMRI.

[24]  J. Felblinger,et al.  Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free‐breathing MRI , 2008, Magnetic resonance in medicine.

[25]  J Keegan,et al.  Hybrid ordered phase encoding (HOPE): An improved approach for respiratory artifact reduction , 1998, Journal of magnetic resonance imaging : JMRI.

[26]  Todd S. Sachs,et al.  The diminishing variance algorithm for real‐time reduction of motion artifacts in MRI , 1995, Magnetic resonance in medicine.

[27]  Markus Hadwiger,et al.  Real-time volume graphics , 2006, Eurographics.

[28]  Markus Henningsson,et al.  Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator , 2013, Magnetic resonance in medicine.

[29]  Cengizhan Ozturk,et al.  Respiratory motion of the heart from free breathing coronary angiograms , 2004, IEEE Transactions on Medical Imaging.

[30]  H. Jara,et al.  T2-weighted MR imaging of the liver: optimization of hybrid-RARE sequences. , 1997, Magnetic resonance imaging.

[31]  Himanshu Bhat,et al.  3D radial sampling and 3D affine transform‐based respiratory motion correction technique for free‐breathing whole‐heart coronary MRA with 100% imaging efficiency , 2011, Magnetic resonance in medicine.

[32]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[33]  David Atkinson,et al.  Artifact Reduction Using Parallel Imaging Methods , 2004, Topics in magnetic resonance imaging : TMRI.

[34]  P. Börnert,et al.  Novel prospective respiratory motion correction approach for free‐breathing coronary MR angiography using a patient‐adapted affine motion model , 2003, Magnetic resonance in medicine.

[35]  D. Firmin,et al.  Phase ordering with automatic window selection (PAWS): A novel motion‐resistant technique for 3D coronary imaging , 2000, Magnetic resonance in medicine.

[36]  J. Felblinger,et al.  Generalized MRI reconstruction including elastic physiological motion and coil sensitivity encoding , 2008, Magnetic resonance in medicine.

[37]  P Börnert,et al.  Motion pattern adapted real‐time respiratory gating , 1999, Magnetic resonance in medicine.

[38]  Debiao Li,et al.  A respiratory self‐gating technique with 3D‐translation compensation for free‐breathing whole‐heart coronary MRA , 2009, Magnetic resonance in medicine.

[39]  J Keegan,et al.  A fully automatic and highly efficient navigator gating technique for high‐resolution free‐breathing acquisitions: Continuously adaptive windowing strategy , 2010, Magnetic resonance in medicine.

[40]  J Felblinger,et al.  Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering , 1994, Magnetic resonance in medicine.

[41]  Jenny Benois-Pineau,et al.  Robust Real-Time-Constrained Estimation of Respiratory Motion for Interventional MRI on Mobile Organs , 2012, IEEE Transactions on Information Technology in Biomedicine.

[42]  R. Razavi,et al.  Prospective High-Resolution Respiratory-Resolved Whole-Heart MRI for Image-Guided Cardiovascular Interventions , 2011, Magnetic resonance in medicine.

[43]  Guang-Zhong Yang,et al.  Non‐model‐based correction of respiratory motion using beat‐to‐beat 3D spiral fat‐selective imaging , 2007, Journal of magnetic resonance imaging : JMRI.

[44]  S. Nielles-Vallespin,et al.  Respiratory self‐navigation for whole‐heart bright‐blood coronary MRI: Methods for robust isolation and automatic segmentation of the blood pool , 2012, Magnetic resonance in medicine.

[45]  Leonardo Acho,et al.  Fast autofocus algorithm for automated microscopes , 2005 .

[46]  M. McConnell,et al.  Prospective navigator correction of image position for coronary MR angiography. , 1997, Radiology.

[47]  S. Riederer,et al.  Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. , 1996, Radiology.

[48]  Olaf Dössel,et al.  Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3-D image registration , 2002, IEEE Transactions on Medical Imaging.

[49]  René M. Botnar,et al.  Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging , 2001, Journal of magnetic resonance imaging : JMRI.

[50]  Vahid Tarokh,et al.  Compressed‐sensing motion compensation (CosMo): A joint prospective–retrospective respiratory navigator for coronary MRI , 2011, Magnetic resonance in medicine.

[51]  Alastair J. Martin,et al.  Whole‐heart steady‐state free precession coronary artery magnetic resonance angiography , 2003, Magnetic resonance in medicine.

[52]  P. Batchelor,et al.  Matrix description of general motion correction applied to multishot images , 2005, Magnetic resonance in medicine.

[53]  P. Börnert,et al.  Prospective correction of affine motion for arbitrary MR sequences on a clinical scanner , 2005, Magnetic resonance in medicine.

[54]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[55]  Kan Takeda,et al.  Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography. , 2006, Journal of the American College of Cardiology.

[56]  S. Riederer,et al.  Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.

[57]  René M. Botnar,et al.  Coronary magnetic resonance angiography for the detection of coronary stenoses. , 2001, The New England journal of medicine.

[58]  Todd S. Sachs,et al.  The real-time interactive 3-D-DVA for robust coronary MRA , 2000, IEEE Transactions on Medical Imaging.