Free‐Breathing 3D Cardiac MRI Using Iterative Image‐Based Respiratory Motion Correction
暂无分享,去创建一个
Markus Henningsson | Sébastien Roujol | Reza Nezafat | Warren J Manning | Kraig V Kissinger | Beth Goddu | Susie N Hong | Mehdi H Moghari | Lois Goepfert | Raymond H Chan | Long H Ngo | Natalie Bello
[1] Robin M Heidemann,et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.
[2] Debiao Li,et al. A dual‐projection respiratory self‐gating technique for whole‐heart coronary MRA , 2008, Journal of magnetic resonance imaging : JMRI.
[3] Andrew C Larson,et al. Self‐gated cardiac cine MRI , 2004, Magnetic resonance in medicine.
[4] Reza Nezafat,et al. Motion correction using coil arrays (MOCCA) for free‐breathing cardiac cine MRI , 2011, Magnetic resonance in medicine.
[5] David Atkinson,et al. A study of the motion and deformation of the heart due to respiration , 2002, IEEE Transactions on Medical Imaging.
[6] René M. Botnar,et al. Impact of navigator timing on free‐breathing submillimeter 3D coronary magnetic resonance angiography , 2002, Magnetic resonance in medicine.
[7] Peter Boesiger,et al. Nonrigid retrospective respiratory motion correction in whole‐heart coronary MRA , 2011, Magnetic resonance in medicine.
[8] Andrew C Larson,et al. Preliminary investigation of respiratory self‐gating for free‐breathing segmented cine MRI , 2005, Magnetic resonance in medicine.
[9] Warren J Manning,et al. Coronary MRI: more pretty pictures or present-day value? , 2006, Journal of the American College of Cardiology.
[10] Use of respiratory biofeedback and CLAWS for increased navigator efficiency for imaging the thoracic aorta , 2011, Magnetic resonance in medicine.
[11] D. Firmin,et al. Motion in cardiovascular MR imaging. , 2009, Radiology.
[12] Elliot R. McVeigh,et al. Displacement and velocity of the coronary arteries: cardiac and respiratory motion , 2006, IEEE Transactions on Medical Imaging.
[13] K. Katahira,et al. Assessment of coronary artery disease using magnetic resonance coronary angiography: a national multicenter trial. , 2010, Journal of the American College of Cardiology.
[14] Vahid Tarokh,et al. Low‐dimensional‐structure self‐learning and thresholding: Regularization beyond compressed sensing for MRI Reconstruction , 2011, Magnetic resonance in medicine.
[15] D. Donoho,et al. Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.
[16] P. Börnert,et al. Free‐breathing whole‐heart coronary MRA with 3D radial SSFP and self‐navigated image reconstruction , 2005, Magnetic resonance in medicine.
[17] Markus Henningsson,et al. Whole‐heart coronary MR angiography with 2D self‐navigated image reconstruction , 2012, Magnetic resonance in medicine.
[18] J Felblinger,et al. Synchronization device for electrocardiography-gated echo-planar imaging. , 1995, Radiology.
[19] J Keegan,et al. 3D coronary artery imaging with phase reordering for improved scan efficiency , 1999, Magnetic resonance in medicine.
[20] René M. Botnar,et al. “Soap‐Bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiograms , 2002, Magnetic resonance in medicine.
[21] M Weiger,et al. Motion‐adapted gating based on k‐space weighting for reduction of respiratory motion artifacts , 1997, Magnetic resonance in medicine.
[22] Debiao Li,et al. Respiratory self‐gated four‐dimensional coronary MR angiography: A feasibility study , 2008, Magnetic resonance in medicine.
[23] Kay Nehrke,et al. Improved bulk myocardial motion suppression for navigator‐gated coronary magnetic resonance imaging , 2007, Journal of magnetic resonance imaging : JMRI.
[24] J. Felblinger,et al. Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free‐breathing MRI , 2008, Magnetic resonance in medicine.
[25] J Keegan,et al. Hybrid ordered phase encoding (HOPE): An improved approach for respiratory artifact reduction , 1998, Journal of magnetic resonance imaging : JMRI.
[26] Todd S. Sachs,et al. The diminishing variance algorithm for real‐time reduction of motion artifacts in MRI , 1995, Magnetic resonance in medicine.
[27] Markus Hadwiger,et al. Real-time volume graphics , 2006, Eurographics.
[28] Markus Henningsson,et al. Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator , 2013, Magnetic resonance in medicine.
[29] Cengizhan Ozturk,et al. Respiratory motion of the heart from free breathing coronary angiograms , 2004, IEEE Transactions on Medical Imaging.
[30] H. Jara,et al. T2-weighted MR imaging of the liver: optimization of hybrid-RARE sequences. , 1997, Magnetic resonance imaging.
[31] Himanshu Bhat,et al. 3D radial sampling and 3D affine transform‐based respiratory motion correction technique for free‐breathing whole‐heart coronary MRA with 100% imaging efficiency , 2011, Magnetic resonance in medicine.
[32] P. Boesiger,et al. SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.
[33] David Atkinson,et al. Artifact Reduction Using Parallel Imaging Methods , 2004, Topics in magnetic resonance imaging : TMRI.
[34] P. Börnert,et al. Novel prospective respiratory motion correction approach for free‐breathing coronary MR angiography using a patient‐adapted affine motion model , 2003, Magnetic resonance in medicine.
[35] D. Firmin,et al. Phase ordering with automatic window selection (PAWS): A novel motion‐resistant technique for 3D coronary imaging , 2000, Magnetic resonance in medicine.
[36] J. Felblinger,et al. Generalized MRI reconstruction including elastic physiological motion and coil sensitivity encoding , 2008, Magnetic resonance in medicine.
[37] P Börnert,et al. Motion pattern adapted real‐time respiratory gating , 1999, Magnetic resonance in medicine.
[38] Debiao Li,et al. A respiratory self‐gating technique with 3D‐translation compensation for free‐breathing whole‐heart coronary MRA , 2009, Magnetic resonance in medicine.
[39] J Keegan,et al. A fully automatic and highly efficient navigator gating technique for high‐resolution free‐breathing acquisitions: Continuously adaptive windowing strategy , 2010, Magnetic resonance in medicine.
[40] J Felblinger,et al. Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering , 1994, Magnetic resonance in medicine.
[41] Jenny Benois-Pineau,et al. Robust Real-Time-Constrained Estimation of Respiratory Motion for Interventional MRI on Mobile Organs , 2012, IEEE Transactions on Information Technology in Biomedicine.
[42] R. Razavi,et al. Prospective High-Resolution Respiratory-Resolved Whole-Heart MRI for Image-Guided Cardiovascular Interventions , 2011, Magnetic resonance in medicine.
[43] Guang-Zhong Yang,et al. Non‐model‐based correction of respiratory motion using beat‐to‐beat 3D spiral fat‐selective imaging , 2007, Journal of magnetic resonance imaging : JMRI.
[44] S. Nielles-Vallespin,et al. Respiratory self‐navigation for whole‐heart bright‐blood coronary MRI: Methods for robust isolation and automatic segmentation of the blood pool , 2012, Magnetic resonance in medicine.
[45] Leonardo Acho,et al. Fast autofocus algorithm for automated microscopes , 2005 .
[46] M. McConnell,et al. Prospective navigator correction of image position for coronary MR angiography. , 1997, Radiology.
[47] S. Riederer,et al. Navigator-echo-based real-time respiratory gating and triggering for reduction of respiration effects in three-dimensional coronary MR angiography. , 1996, Radiology.
[48] Olaf Dössel,et al. Model evaluation and calibration for prospective respiratory motion correction in coronary MR angiography based on 3-D image registration , 2002, IEEE Transactions on Medical Imaging.
[49] René M. Botnar,et al. Impact of bulk cardiac motion on right coronary MR angiography and vessel wall imaging , 2001, Journal of magnetic resonance imaging : JMRI.
[50] Vahid Tarokh,et al. Compressed‐sensing motion compensation (CosMo): A joint prospective–retrospective respiratory navigator for coronary MRI , 2011, Magnetic resonance in medicine.
[51] Alastair J. Martin,et al. Whole‐heart steady‐state free precession coronary artery magnetic resonance angiography , 2003, Magnetic resonance in medicine.
[52] P. Batchelor,et al. Matrix description of general motion correction applied to multishot images , 2005, Magnetic resonance in medicine.
[53] P. Börnert,et al. Prospective correction of affine motion for arbitrary MR sequences on a clinical scanner , 2005, Magnetic resonance in medicine.
[54] J. Felmlee,et al. Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.
[55] Kan Takeda,et al. Detection of coronary artery stenosis with whole-heart coronary magnetic resonance angiography. , 2006, Journal of the American College of Cardiology.
[56] S. Riederer,et al. Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging , 1995, Magnetic resonance in medicine.
[57] René M. Botnar,et al. Coronary magnetic resonance angiography for the detection of coronary stenoses. , 2001, The New England journal of medicine.
[58] Todd S. Sachs,et al. The real-time interactive 3-D-DVA for robust coronary MRA , 2000, IEEE Transactions on Medical Imaging.