Blood flow distribution in a polymyxin coated fibrous bed for endotoxin removal. Effect of a new blood path design

The analysis of flow distribution in cartridges designed for hemoperfusion is extremely important. Taking advantage of a new imaging technique, based on the analysis of a helical scanner-generated imaging sequence, we studied the blood flow distribution in a series of cartridges for extracorporeal removal of endotoxin. Cartridges with improved design were compared to cartridges with a standard design. The improved design consists in a different structure of the holes of the distributor of the flow within the adsorbent unit. Cartridges were studied in vitro with human blood from voluntary donors at blood flows of 100 and 250 ml/min. The progression of density in specific regions of interest (ROI) was analyzed to detect the distribution of the dye injected in the blood circuit. The study demonstrates that both at 100 ml/min and at 250 ml/min of blood flow, the progression of flow appears more homogeneous in the devices with improved design. In detail, the flow distribution measured by the incremental density values detected in the ROIs of the proximal corners (close to the arterial port) and in the ROIs of the central region of the device (close to the inner wall of the case) displays a significant difference between the standard and the improved device. The ROIs studied in the standard devices display a slower increase in density and significantly lower absolute values expressed in Hounsfield units. The experimental method utilized to analyze flow distribution seems to represent an important means to study the performance and design of this type of device.

[1]  C. Ronco,et al.  Blood Flow Distribution in Sorbent Beds: Analysis of a new Sorbent Device for Hemoperfusion , 2000, The International journal of artificial organs.

[2]  R. Bellomo,et al.  Use of adsorptive mechanisms in continuous renal replacement therapies in the critically ill. , 1999, Kidney international. Supplement.

[3]  A. Cheung,et al.  Effect of dialysis membranes and middle molecule removal on chronic hemodialysis patient survival. , 1999, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[4]  C. Ronco,et al.  The Concept of Sorbent in Hemodialysis , 1998, The International journal of artificial organs.

[5]  C. Ronco,et al.  Effects of different membranes and dialysis technologies on patient treatment tolerance and nutritional parameters. The Italian Cooperative Dialysis Study Group. , 1996, Kidney international.

[6]  Chi-hung Cheng,et al.  Statistical and Parametric Analysis of Beta‐2‐Microglobulin Removal from Uremic Patients in High Flux Hemodialysis , 1994, ASAIO journal.

[7]  B. Branger,et al.  High-flux synthetic versus cellulosic membranes for beta 2-microglobulin removal during hemodialysis, hemodiafiltration and hemofiltration. , 1989, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[8]  C. Ronco,et al.  Technical and clinical evaluation of different short, highly efficient dialysis techniques. , 1988, Contributions to nephrology.