The influence of air humidity on an unsealed ionization chamber in a linear accelerator.

The safe and accurate delivery of the prescribed absorbed dose is the central function of the dose monitoring and beam stabilization system in a medical linear accelerator. The absorbed dose delivered to the patient during radiotherapy is often monitored by a transmission ionization chamber. Therefore it is of utmost importance that the chamber behaves correctly. We have noticed that the sensitivity of an unsealed chamber in a Philips SL linear accelerator changes significantly, especially during and after the summer season. The reason for this is probably a corrosion effect of the conductive plates in the chamber due to the increased relative humidity during hot periods. We have found that the responses of the different ion chamber plates change with variations in air humidity and that they do not return to their original values when the air humidity is returned to ambient conditions.

[1]  I. Rosen,et al.  Long term variation in beam symmetry as a function of gantry angle for a computer-controlled linear accelerator. , 1989, Medical Physics (Lancaster).

[2]  P. Cheng,et al.  Unexpectedly large dose rate dependent output from a linear accelerator. , 1988, Medical physics.

[3]  T. M. Kehoe,et al.  A testing jig for sealed beam monitors. , 1987, Physics in Medicine and Biology.

[4]  D. Cormack,et al.  Detection of a leak in a "sealed" monitor chamber. , 1985, Medical Physics (Lancaster).

[5]  A. Hrejsa,et al.  Temperature-pressure compensation for a linear accelerator electron beam dosimeter. , 1985, Medical Physics (Lancaster).

[6]  E S Sternick,et al.  Reduction of the "horns" observed on the beam profiles of a 6-MV linear accelerator. , 1984, Medical physics.

[7]  C. J. Karzmark,et al.  Advances in linear accelerator design for radiotherapy. , 1984, Medical physics.

[8]  D. Wilson,et al.  Variation of output with atmospheric pressure and ambient temperature for Therac-20 linear accelerator. , 1983, Medical Physics (Lancaster).

[9]  M. Gillin,et al.  Variation in output with a fixed dose setting on a 4-MV linear accelerator. , 1976, Medical Physics (Lancaster).

[10]  P. C. Williams,et al.  An instrument for measuring small differences in dose rate at points in a radiation beam. , 1971, Physics in medicine and biology.

[11]  M Loyd,et al.  Dose delivery error detection by a computer-controlled linear accelerator. , 1989, Medical physics.

[12]  H Svensson,et al.  Calibration and use of plane-parallel ionization chambers for the determination of absorbed dose in electron beams. , 1981, Acta radiologica. Oncology.

[13]  W. Sutherland Dose monitoring methods in medical linear accelerators. , 1969, The British journal of radiology.