Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass Instrument

Purpose. To objectively determine the effects of pupil size on optical quality parameters in astigmatic eyes using a double-pass instrument. Methods. We examined twenty-two eyes of 22 healthy volunteers (mean age ± standard deviation, 27.1 ± 2.8 years) who had no ophthalmic diseases other than refractive errors (manifest cylinder ≤0.25 diopters (D)). After we fully corrected cycloplegic refraction, we created with-the-rule astigma tism of 1, 2, and 3 diopters in these eyes and then quantitatively assessed the modulation transfer function (MTF) cutoff frequency and the Strehl2D ratio with 2-, 4-, and 6-mm pupil sizes using the Optical Quality Analysis System. Results. The MTF cutoff frequency and the Strehl2D ratio decreased significantly as the amount of astigmatism increased at each pupil size (P < 0.001 for 2, 4, and 6 mm, analysis of variance). They also decreased significantly with an increase in pupil size at each diopter of astigmatism (P < 0.001 for 0, 1, 2, and 3 D). Multiple comparisons demonstrated a significant difference between measurements made for a 2-mm pupil and for a 6-mm pupil at each diopter of astigmatism (P < 0.001 for 0, 1, 2, and 3 D, Dunnett test) and those made for a 4-mm pupil and for a 6-mm pupil at each diopter of astigmatism (P < 0.001 for 0 D, P < 0.05 1, 2, and 3 D). Conclusions. Eyes with larger pupils had lower optical quality even when they were astigmatic. It may be necessary to correct the preexisting astigmatism to acquire excellent visual performance, especially in astigmatic eyes with larger pupils.

[1]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[2]  Alain Saad,et al.  Repeatability of measurements with a double‐pass system , 2010, Journal of cataract and refractive surgery.

[3]  Robert Montés-Micó,et al.  Prevalence of corneal astigmatism before cataract surgery , 2009, Journal of cataract and refractive surgery.

[4]  Scott A. Read,et al.  A review of astigmatism and its possible genesis , 2007, Clinical & experimental optometry.

[5]  Laurent Degos,et al.  HISTOCOMPATIBILITY DETERMINANTS IN MULTIPLE SCLEROSIS , 1974 .

[6]  W. Hütz,et al.  Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyes , 2010, Journal of cataract and refractive surgery.

[7]  K. Shimizu,et al.  Effect of pupil size on uncorrected visual acuity in astigmatic eyes , 2011, British Journal of Ophthalmology.

[8]  D E Mitchell,et al.  The effect of early astigmatism on the visual resolution of gratings , 1974, The Journal of physiology.

[9]  Jaume Pujol,et al.  Optical quality one month after verisyse and Veriflex phakic IOL implantation and Zeiss MEL 80 LASIK for myopia from 5.00 to 16.50 diopters. , 2009, Journal of refractive surgery.

[10]  R. Navarro,et al.  Monochromatic modulation transfer function of the human eye for different pupil diameters: an analytical expression. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.

[11]  J Pujol,et al.  Influence of amount and changes in axis of astigmatism on retinal image quality. , 1998, Journal of the Optical Society of America. A, Optics, image science, and vision.

[12]  Jaume Pujol,et al.  Optical Quality Analysis System; Instrument for objective clinical evaluation of ocular optical quality. , 2004, Journal of cataract and refractive surgery.

[13]  Jaume Pujol,et al.  Intra- and Intersession Repeatability of a Double-Pass Instrument , 2010, Optometry and vision science : official publication of the American Academy of Optometry.

[14]  P. Allen,et al.  Repeatability and Validity of the PowerRefractor and the Nidek AR600-A in an Adult Population with Healthy Eyes , 2003, Optometry and vision science : official publication of the American Academy of Optometry.

[15]  José M Artigas,et al.  Image quality with multifocal intraocular lenses and the effect of pupil size: Comparison of refractive and hybrid refractive–diffractive designs , 2007, Journal of cataract and refractive surgery.

[16]  R. Navarro,et al.  Modulation transfer of the human eye as a function of retinal eccentricity. , 1993, Journal of the Optical Society of America. A, Optics and image science.

[17]  D A Atchison,et al.  The Effect of Pupil Size on Visual Acuity in Uncorrected and Corrected Myopia , 1979, American journal of optometry and physiological optics.