Long-term monitoring and field testing of an innovative multistory timber building

An innovative three-story timber building, using self-centering, post-tensioned timber shear walls as the main horizontal load resisting system and lightweight composite timber-concrete floors, has recently been completed in Nelson, New Zealand. It is expected to be the trailblazer for similar but taller structures to be more widely adopted. Performance based standards require an advanced understanding of building responses and in order to meet the need for in-situ performance data the building has been subjected to forced vibration testing and instrumented for continuous monitoring using a total of about 90 data channels to capture its dynamic and long-term responses. The first part of the paper presents a brief discussion of the existing research on the seismic performance of timber frame buildings and footfall induced floor vibrations. An outline of the building structural system, focusing on the novel design solutions, is then discussed. This is followed by the description of the monitoring system. The paper emphasizes the need for optimal placement of a limited number of sensors and demonstrates how this was achieved for monitoring floor vibrations with the help of the effective independence-driving point residue (EfI-DPR) technique. A novel approach to the EfI-DPR method proposed here uses a combinatorial search algorithm that increases the chances of obtaining the globally optimal solution. Finally, the results from the forced vibration tests conducted on the whole building at different construction stages are reviewed.

[1]  Hugo Bachmann,et al.  Vibration Problems in Structures: Practical Guidelines , 1994 .

[2]  Prasad Samarajiva,et al.  Vibration Study of a Proposed Fitness Center Adjacent to a Server Room , 2009 .

[3]  Yoshiji Matsumoto,et al.  A STUDY ON DYNAMIC DESIGN OF PEDESTRIAN OVER-BRIDGES TN CONSIDERATION OF CHARACTERISTICS OF PEDETRIANS , 1972 .

[4]  Linda M. Hanagan,et al.  A Unique Vibration Serviceability Case Study of a Complex Structure , 2006 .

[5]  B. R Ellis,et al.  Dynamic testing and stiffness evaluation of a six-storey timber framed building during construction , 2001 .

[6]  Andre Filiatrault,et al.  Seismic Testing of Two-Story Woodframe House: Influence of Wall Finish Materials , 2002 .

[7]  Paul Reynolds,et al.  Vibration serviceability of long-span concrete building floors. Part 1: Review of background information , 2002 .

[8]  Stefano Pampanin,et al.  FABRICATION AND ASSEMBLY OF A TWO-STOREY POST-TENSIONED TIMBER BUILDING , 2010 .

[9]  Andre Filiatrault,et al.  Performance-Based Seismic Design of Wood Framed Buildings , 2002 .

[10]  John W. van de Lindt,et al.  Experimental Seismic Response of a Full-Scale Light-Frame Wood Building , 2010 .

[11]  Andre Filiatrault,et al.  Hysteretic damping of wood framed buildings , 2003 .

[12]  John E. Mottershead,et al.  Finite Element Model Updating in Structural Dynamics , 1995 .

[13]  Dryver R. Huston,et al.  Monitoring of microfloor vibrations in a new research building , 2002, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[14]  S. R. Uma,et al.  THE GEONET BUILDING INSTRUMENTATION PROGRAMME , 2011 .

[15]  Christoph Heinemeyer,et al.  Design Guide for Floor Vibrations , 2008 .

[16]  L. Megget,et al.  Bulletin of the New Zealand society for earthquake engineering , 2002 .

[17]  Daniel C. Kanner Sensor Placement for On-Orbit Modal Identification and Correlation of Large Space Structures , 1990 .

[18]  Vanessa Sabrina Camelo Dynamic characteristics of woodframe buildings , 2003 .

[19]  Carmelo Gentile,et al.  Ambient vibration testing and structural evaluation of an historic suspension footbridge , 2008, Adv. Eng. Softw..

[20]  Khalid M. Mosalam,et al.  Seismic Evaluation and Retrofit of Asymmetric Multi-Story Wood-Frame Building , 2007 .

[21]  David V. Rosowsky,et al.  Direct Displacement Procedure for Performance-Based Seismic Design of Mid-Rise Wood-Framed Structures , 2009 .

[22]  T P Andriacchi,et al.  Walking speed as a basis for normal and abnormal gait measurements. , 1977, Journal of biomechanics.

[23]  D R Leonard Human tolerance levels for bridge vibrations , 1966 .

[24]  Bart Peeters,et al.  System identification and damage detection in civil engineering , 2000 .

[25]  John F. Stanton,et al.  A weighted-stretched-wire system for monitoring deflections , 2003 .

[26]  D. Kammer Sensor Placement for On-Orbit Modal Identification and Correlation of Large Space Structures , 1990, 1990 American Control Conference.

[27]  Michael L. Tinker,et al.  Optimal placement of triaxial accelerometers for modal vibration tests , 2002 .

[28]  Daniel Sutoyo,et al.  Hysteretic characteristics of wood-frame structures under seismic motions , 2009 .

[29]  B. Peeters,et al.  Stochastic System Identification for Operational Modal Analysis: A Review , 2001 .

[30]  Michele Meo,et al.  On the optimal sensor placement techniques for a bridge structure , 2005 .

[31]  John W. van de Lindt,et al.  Shake table testing of a full-scale seven-story steel–wood apartment building , 2011 .