A prospective evaluation of helical tomotherapy.

PURPOSE To report results from two clinical trials evaluating helical tomotherapy (HT). METHODS AND MATERIALS Patients were enrolled in one of two prospective trials of HT (one for palliative and one for radical treatment). Both an HT plan and a companion three-dimensional conformal radiotherapy (3D-CRT) plan were generated. Pretreatment megavoltage computed tomography was used for daily image guidance. RESULTS From September 2004 to January 2006, a total of 61 sites in 60 patients were treated. In all but one case, a clinically acceptable tomotherapy plan for treatment was generated. Helical tomotherapy plans were subjectively equivalent or superior to 3D-CRT in 95% of plans. Helical tomotherapy was deemed equivalent or superior in two thirds of dose-volume point comparisons. In cases of inferiority, differences were either clinically insignificant and/or reflected deliberate tradeoffs to optimize the HT plan. Overall imaging and treatment time (median) was 27 min (range, 16-91 min). According to a patient questionnaire, 78% of patients were satisfied to very satisfied with the treatment process. CONCLUSIONS Helical tomotherapy demonstrated clear advantages over conventional 3D-CRT in this diverse patient group. The prospective trials were helpful in deploying this technology in a busy clinical setting.

[1]  C. Langer,et al.  Concurrent chemoradiation using paclitaxel and carboplatin in locally advanced non-small cell lung cancer. , 1999, Seminars in radiation oncology.

[2]  T R Mackie,et al.  A feasible method for clinical delivery verification and dose reconstruction in tomotherapy. , 2001, Medical physics.

[3]  J. Fowler,et al.  Reduction in Radiation Dose to Lung and Other Normal Tissues Using Helical Tomotherapy to Treat Lung Cancer, in Comparison to Conventional Field Arrangements , 2003, American journal of clinical oncology.

[4]  Tomas Kron,et al.  A comparison of prostate IMRT and helical tomotherapy class solutions. , 2006, Radiotherapy and Oncology.

[5]  Cedric X. Yu,et al.  Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study , 2005, Physics in medicine and biology.

[6]  E. Wong,et al.  Planning evaluation of radiotherapy for complex lung cancer cases using helical tomotherapy. , 2004, Physics in medicine and biology.

[7]  L. Cozzi,et al.  Tomotherapy planning of small brain tumours. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[8]  Hazim Jaradat,et al.  Integral radiation dose to normal structures with conformal external beam radiation. , 2005, International journal of radiation oncology, biology, physics.

[9]  Yulong Yan,et al.  Feasibility of cranio-spinal axis radiation with the Hi-Art tomotherapy system. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  E. Hall,et al.  Intensity-modulated radiation therapy, protons, and the risk of second cancers. , 2006, International journal of radiation oncology, biology, physics.

[11]  B. Fisher,et al.  Helical tomotherapy for craniospinal radiation. , 2005, The British journal of radiology.

[12]  T. Mackie,et al.  Iterative approaches to dose optimization in tomotherapy. , 2000, Physics in medicine and biology.

[13]  Robert Jeraj,et al.  A novel method to correct for pitch and yaw patient setup errors in helical tomotherapy. , 2005, Medical physics.

[14]  S. Cora,et al.  Comparison of advanced irradiation techniques with photons for benign intracranial tumours. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  Comparative planning evaluation of intensity-modulated radiotherapy techniques for complex lung cancer cases. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  Aaron Fenster,et al.  Prostate contouring uncertainty in megavoltage computed tomography images acquired with a helical tomotherapy unit during image-guided radiation therapy. , 2006, International journal of radiation oncology, biology, physics.

[17]  M. Mehta,et al.  Comparison of linac based fractionated stereotactic radiotherapy and tomotherapy treatment plans for skull-base tumors. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[18]  J. Battista,et al.  Investigation of dose homogeneity for loose helical tomotherapy delivery in the context of breath-hold radiation therapy. , 2005, Physics in medicine and biology.

[19]  E. Wong,et al.  Intensity-modulated arc therapy simplified. , 2002, International journal of radiation oncology, biology, physics.

[20]  Jan J W Lagendijk,et al.  Comparing step-and-shoot IMRT with dynamic helical tomotherapy IMRT plans for head-and-neck cancer. , 2005, International journal of radiation oncology, biology, physics.

[21]  T R Mackie,et al.  Quality assurance of a helical tomotherapy machine. , 2004, Physics in medicine and biology.

[22]  John Balog,et al.  Clinical helical tomotherapy commissioning dosimetry. , 2003, Medical physics.

[23]  W. Tomé,et al.  Total scalp irradiation using helical tomotherapy. , 2005, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[24]  T Kron,et al.  Optimization of helical tomotherapy treatment plans for prostate cancer. , 2003, Physics in medicine and biology.