Urea biosensor based on amperometric pH-sensing with hematein as a pH-sensitive redox mediator.

The natural dye hematein in water solution was used as a pH-sensitive redox-active mediator for amperometric pH-sensing. The electrochemical characteristics were studied using cyclic voltammetry and chronoamperometry. Several types of urea biosensors were constructed with urease on the surface of platinum and graphite composite electrodes or in the bulk of the graphite composite. They were used for the amperometric urea determination at a working potential of 0 mV (versus SCE) using 0.5 mM hematein. Detection limits and response linearity was in the micromolar range depending on the biosensor type, concentration and pH of buffers used. An interference study of various cations, anions, and substances, which may be present in real samples demonstrated good selectivity for the determination of urea. The biosensors showed good operational (>3 h) and storage (>3 months) stability. The results of urea determination in blood and urine obtained by biosensor correlated well with those obtained by a spectrophotometric reference method.

[1]  S. Miertus,et al.  Composite transducers for amperometric biosensors. The glucose sensor. , 1997, Analytical chemistry.

[2]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[3]  K. Cammann,et al.  A disposable biosensor for urea determination in blood based on an ammonium-sensitive transducer. , 1999, Biosensors & bioelectronics.

[4]  Gordon G. Wallace,et al.  Polypyrrole-based potentiometric biosensor for urea: Part 2. Analytical optimisation , 1993 .

[5]  M. G. Bridelli,et al.  The structure of neuromelanin and its iron binding site studied by infrared spectroscopy , 1999, FEBS letters.

[6]  Stanislav Miertus,et al.  Biosensors for L-malate and L-lactate based on solid binding matrix , 1999 .

[7]  S. R. Crouch,et al.  Spectrophotometric and kinetics investigation of the Berthelot reaction for the determination of ammonia , 1977 .

[8]  F. Roch-Ramel An enzymic and fluorophotometric method for estimating urea concentrations in nanoliter specimens. , 1967, Analytical biochemistry.

[9]  A. Hubbard Electrochemistry at well-characterized surfaces , 1988 .

[10]  M. Saraste,et al.  FEBS Lett , 2000 .

[11]  A. Amine,et al.  Preparation and characterization of a fragile enzyme immobilized carbon paste electrode , 1992 .

[12]  R. Lal,et al.  Conducting polymer-based biosensors , 1994 .

[13]  G. Guilbault,et al.  Amperometric determination of urea using an NADH-dependent coupled enzyme. , 1994, Talanta.

[14]  J. Ruzicka,et al.  A new approach to enzymatic assay based on flow-injection spectrophotometry with acid-base indicators , 1980 .

[15]  Hsuan‐Jung Huang,et al.  An Amperometric Urea Biosensor Based on a Polyaniline−Perfluorosulfonated Ionomer Composite Electrode , 1998 .

[16]  S. Miertus,et al.  Amperometric pH-sensing biosensors for urea, penicillin, and oxalacetate , 2000 .

[17]  Joseph G. Montalvo,et al.  Enzyme electrode for the substrate urea , 1970 .

[18]  S. Miertus,et al.  Determination of D-fructose in foodstuffs by an improved amperometric biosensor based on a solid binding matrix , 1999 .

[19]  T. Tatsuma,et al.  Theoretical evaluation of mediation efficiency in enzyme-incorporated electrodes , 1993 .

[20]  Nicole Jaffrezic-Renault,et al.  Conductometric urea sensor. Use of additional membranes for the improvement of its analytical characteristics , 1996 .

[21]  T. Osaka,et al.  Potentiometric biosensor for urea based on electropolymerized electroinactive polypyrrole , 1997 .

[22]  J. Švitel,et al.  Amperometric biosensors based on solid binding matrices applied in food quality monitoring. , 1998, Biosensors & bioelectronics.

[23]  A. Gewirth,et al.  Electrochemical Applications of in Situ Scanning Probe Microscopy. , 1997, Chemical reviews.

[24]  J Wang,et al.  Thermal Stabilization of Enzymes Immobilized within Carbon Paste Electrodes. , 1997, Analytical chemistry.

[25]  S. J. Shaw,et al.  Polypyrrole-based amperometric flow injection biosensor for urea , 1996 .

[26]  R. Koncki,et al.  Kinetic model of pH-based potentiometric enzymic sensors. Part 1. Theoretical considerations , 1991 .