Musculoskeletal imaging in progress: the EOS imaging system.

The EOS 2D/3D radio-imaging device (Biospace med, France) can disclose a digital radiographic image of bones with a very low radiation dose. This in turn allows in obtaining a single image of a large field of view, as wide as the full skeleton. The simultaneous capturing of spatially paired AP and lateral X-ray images is also a specificity of EOS imaging, which further provides secondary 3D (volumic) reformation of skeletal images. The main indications of this new imaging technology are assessment and follow-up of balance disorders of the spine and of the lower limbs.

[1]  W. Skalli,et al.  Le système EOS. Nouvelle imagerie Ostéo-Articulaire basse dose en position debout , 2005 .

[2]  D Mitton,et al.  A Biplanar Reconstruction Method Based on 2D and 3D Contours: Application to the Distal Femur , 2003, Computer methods in biomechanics and biomedical engineering.

[3]  W Skalli,et al.  3D reconstruction of the spine from biplanar X-rays using parametric models based on transversal and longitudinal inferences. , 2009, Medical engineering & physics.

[4]  Y. Catonné,et al.  Orientations du pelvis et de la pièce acétabulaire des prothèses totales de hanche en positions assise et debout : reproductibilité des mesures suivant le système radiographique utilisé, EOS ou conventionnel , 2011 .

[5]  J. A. de Guise,et al.  Modélisation vertébrale et squelettique par le système EOS , 2008 .

[6]  Système EOS : la radiographie de la tête aux pieds face et profil simultanés à très basses doses de radiations , 2007 .

[7]  Antoine Feydy,et al.  Analyse de lespace intervertbral avec un systme de radiographie basse dose , 2005 .

[8]  Chao Yang,et al.  3D reconstruction of the ribs from lateral and frontal X-rays in comparison to 3D CT-scan reconstruction. , 2008, Journal of biomechanics.

[9]  S. Laporte,et al.  Three-dimensional (3D) detailed reconstruction of human vertebrae from low-dose digital stereoradiography , 2003, European Journal of Orthopaedic Surgery & Traumatology.

[10]  Hubert Labelle,et al.  Diagnostic Imaging of Spinal Deformities: Reducing Patients Radiation Dose With a New Slot-Scanning X-ray Imager , 2010, Spine.

[11]  Analyse 3D par radiographie biplanaire basse dose EOS ® des alignements osseux et prothétiques lors de la pose d’une PTG. Incertitude des repères mis en place , 2009 .

[12]  G. Charpak [Prospects for the use in medicine of new detectors of ionizing radiation]. , 1996, Bulletin de l'Academie nationale de medecine.

[13]  W Skalli,et al.  Reproducibility of Measuring the Shape and Three-Dimensional Position of Cervical Vertebrae in Upright Position Using the EOS Stereoradiography System , 2007, Spine.