Electrogram-guided substrate ablation with or without pulmonary vein isolation in patients with persistent atrial fibrillation.

AIMS Ablation of complex fractionated atrial electrograms (CFAEs) is a new approach for the treatment of atrial fibrillation (AF). The purpose of the study was to assess the efficacy of CFAE ablation as a stand-alone strategy in patients with persistent AF and to compare it with a combined approach of CFAE ablation and pulmonary vein isolation (PVI). METHODS AND RESULTS The study included 77 consecutive patients with persistent AF who underwent radiofrequency (RF) ablation of CFAE as a sole ablation procedure (CFAE group, n = 23 patients) or a combined approach of CFAE ablation and PVI (CFAE plus PVI group, n = 54 patients). Procedures were guided by three-dimensional mapping systems. After the procedure, AF recurrences were evaluated with 7-day Holter recordings at 1, 3, and 6 months and every 6 months thereafter. Treatment failure was defined as >or=1 AF episode lasting >30 s on Holter recordings during follow-up. After a mean follow-up time of 13 +/- 10 months, 2 of 23 patients (9%) with CFAE ablation and 22 of 54 patients (41%) with CFAE plus PVI were in sinus rhythm after a single ablation procedure without anti-arrhythmic medication (P = 0.008). CONCLUSION Ablation of CFAE as a stand-alone ablation strategy seems insufficient for the treatment of patients with persistent AF. Pulmonary vein isolation plus CFAE ablation significantly increases the mid-term success rate.

[1]  F. Sacher,et al.  Catheter Ablation of Long‐Lasting Persistent Atrial Fibrillation: Critical Structures for Termination , 2005, Journal of cardiovascular electrophysiology.

[2]  Atul Verma,et al.  A prospective, multicenter evaluation of ablating complex fractionated electrograms (CFEs) during atrial fibrillation (AF) identified by an automated mapping algorithm: acute effects on AF and efficacy as an adjuvant strategy. , 2008, Heart rhythm.

[3]  Sabine Ernst,et al.  Complete Isolation of Left Atrium Surrounding the Pulmonary Veins: New Insights From the Double-Lasso Technique in Paroxysmal Atrial Fibrillation , 2004, Circulation.

[4]  Armin Luik,et al.  Acute effects and long-term outcome of pulmonary vein isolation in combination with electrogram-guided substrate ablation for persistent atrial fibrillation. , 2008, The American journal of cardiology.

[5]  K. Nademanee,et al.  A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. , 2004, Journal of the American College of Cardiology.

[6]  Burr Hall,et al.  Catheter Ablation for Paroxysmal Atrial Fibrillation: Segmental Pulmonary Vein Ostial Ablation Versus Left Atrial Ablation , 2003, Circulation.

[7]  D. Shah,et al.  Narrow, Slow‐Conducting Isthmus Dependent Left Atrial Reentry Developing After Ablation for Atrial Fibrillation: ECG Characterization and Elimination by Focal RF Ablation , 2006, Journal of cardiovascular electrophysiology.

[8]  A. Waldo,et al.  Radiofrequency Catheter Ablation of Chronic Atrial Fibrillation Guided by Complex Electrograms , 2008 .

[9]  Prashanthan Sanders,et al.  Characterization of electrograms associated with termination of chronic atrial fibrillation by catheter ablation. , 2008, Journal of the American College of Cardiology.

[10]  Michael A. E. Schneider,et al.  Circumferential mapping and electric isolation of pulmonary veins in patients with atrial fibrillation. , 2003, The American journal of cardiology.

[11]  Armin Luik,et al.  Radiofrequency Ablation of Complex Fractionated Atrial Electrograms (CFAE): Preferential Sites of Acute Termination and Regularization in Paroxysmal and Persistent Atrial Fibrillation , 2007, Journal of cardiovascular electrophysiology.

[12]  B. Zrenner,et al.  Automatic 3D Mapping of Complex Fractionated Atrial Electrograms (CFAE) in Patients with Paroxysmal and Persistent Atrial Fibrillation , 2008, Journal of cardiovascular electrophysiology.

[13]  D. Wilber,et al.  Prospective Study of Atrial Fibrillation Termination During Ablation Guided by Automated Detection of Fractionated Electrograms , 2008, Journal of cardiovascular electrophysiology.

[14]  Hugh Calkins,et al.  Automated detection and characterization of complex fractionated atrial electrograms in human left atrium during atrial fibrillation. , 2007, Heart rhythm.

[15]  J Clémenty,et al.  Electrophysiological Breakthroughs From the Left Atrium to the Pulmonary Veins , 2000, Circulation.

[16]  M. Allessie,et al.  High-density mapping of electrically induced atrial fibrillation in humans. , 1994, Circulation.

[17]  Hakan Oral,et al.  Pulmonary Vein Isolation for Paroxysmal and Persistent Atrial Fibrillation , 2002, Circulation.

[18]  Douglas L. Jones,et al.  Chronic rapid atrial pacing. Structural, functional, and electrophysiological characteristics of a new model of sustained atrial fibrillation. , 1995, Circulation.

[19]  Bertil Olsson,et al.  Outcome parameters for trials in atrial fibrillation: executive summary. , 2007, European heart journal.