Load Leveling and Voltage Control of Permanent Magnet Synchronous Generator-Based DG Set for Standalone Supply System

This paper deals with the voltage control and load leveling of permanent magnet synchronous generator (PMSG)-based diesel generator (DG) set for standalone supply system. The proposed system is composed of a PMSG and a prototype of diesel engine (DE), along with the distribution static compensator (DSTATCOM) and battery energy storage system (BESS). The DSTATCOM along with BESS is used for loads leveling and voltage control. It also provides balancing of loads, elimination of harmonics, and compensation of reactive power. The battery on dc link of voltage source converter (VSC) of DSTATCOM is used to supply the active power when the load is more than PMSG rating, and it stores the energy during light load periods. The PMSG is always loaded with an optimum load of 80%-100% of its rating. An optimum loading of DG set helps in improving the fuel efficiency of the DE and also helps in load leveling. The reference source currents are estimated using a hyperbolic tangent function-based least mean square (LMS) algorithm. This control algorithm has reduced computation and provides fast convergence rate to eliminate the effect of noise as compared with other LMS algorithms based on adaptive filtering. The voltage control, load compensation, and fuel efficiency improvement in PMSG-based DG set using BESS and DSTATCOM controlled by hyperbolic tangent function-based LMS algorithm are the main contributions of this paper.

[1]  Mukhtiar Singh,et al.  Real-Time Implementation of ANFIS Control for Renewable Interfacing Inverter in 3P4W Distribution Network , 2013, IEEE Transactions on Industrial Electronics.

[2]  Ritwik Majumder,et al.  Reactive Power Compensation in Single-Phase Operation of Microgrid , 2013, IEEE Transactions on Industrial Electronics.

[3]  A. Venturato,et al.  Novel control technique for high-performance diesel-driven AC generator-sets , 2000 .

[4]  Kamal Al-Haddad,et al.  A New Control Technique for Three-Phase Shunt Hybrid Power Filter , 2009, IEEE Transactions on Industrial Electronics.

[5]  Mahesh Kumar Mishra,et al.  DC Capacitor Voltage Equalization in Neutral Clamped Inverters for DSTATCOM Application , 2010, IEEE Transactions on Industrial Electronics.

[6]  Bhim Singh,et al.  Back-Propagation Control Algorithm for Power Quality Improvement Using DSTATCOM , 2014, IEEE Transactions on Industrial Electronics.

[7]  José R. Espinoza,et al.  FPGA v/s DSP Performance Comparison for a VSC-Based STATCOM Control Application , 2013, IEEE Transactions on Industrial Informatics.

[8]  S. A. Papathanassiou,et al.  Operating Policy and Optimal Sizing of a High Penetration RES-BESS System for Small Isolated Grids , 2011, IEEE Transactions on Energy Conversion.

[9]  A. Oudalov,et al.  Optimizing a Battery Energy Storage System for Frequency Control Application in an Isolated Power System , 2009, IEEE Transactions on Power Systems.

[10]  Zhankui Wang,et al.  An novel variable step size LMS adaptive filtering algorithm based on hyperbolic tangent function , 2010, 2010 International Conference on Computer Application and System Modeling (ICCASM 2010).

[11]  Luca Solero,et al.  Adaptive Direct-Tuning Control for Variable-Speed Diesel-Electric Generating Units , 2012, IEEE Transactions on Industrial Electronics.

[12]  Luo Shiguo,et al.  An adaptive detecting method for harmonic and reactive currents , 1993, Proceedings of TENCON '93. IEEE Region 10 International Conference on Computers, Communications and Automation.

[13]  Bhim Singh,et al.  Design and Implementation of Four-Leg Voltage-Source-Converter-Based VFC for Autonomous Wind Energy Conversion System , 2012, IEEE Transactions on Industrial Electronics.

[14]  B. Muralimohan,et al.  Reduced Rating VSC with a Zig-Zag Transformer for Current Compensation in a Three-Phase Four-Wire Distribution System , 2012 .

[15]  Weimin Wang,et al.  Permanent-Magnet Synchronous Generator Supplying an Isolated Load , 2010, IEEE Transactions on Magnetics.

[16]  Alexandru Bitoleanu,et al.  A DSP-Based Implementation of the p-q Theory in Active Power Filtering Under Nonideal Voltage Conditions , 2013, IEEE Transactions on Industrial Informatics.

[17]  Mutsuo Nakaoka,et al.  Digital control three-phase shunt active power filter with a new harmonic-current-extraction process , 2005 .

[18]  Bhim Singh,et al.  A Comparison of Control Algorithms for DSTATCOM , 2009, IEEE Transactions on Industrial Electronics.

[19]  R. L. de Araújo Ribeiro,et al.  A Robust Adaptive Control Strategy of Active Power Filters for Power-Factor Correction, Harmonic Compensation, and Balancing of Nonlinear Loads , 2012, IEEE Transactions on Power Electronics.

[20]  R. L. de Araujo Ribeiro,et al.  A Robust Adaptive Control Strategy of Active Power Filters for Power-Factor Correction, Harmonic Compensation, and Balancing of Nonlinear Loads , 2012 .

[21]  Shebin El-Kom,et al.  MODELLING AND CONTROLLER DESIGN OF AN ISOLATED DIESEL ENGINE PERMANENT MAGNET SYNCHRONOUS GENERATOR , 1996 .

[22]  Kamal Al-Haddad,et al.  An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads , 2000 .

[23]  Ping Xue,et al.  Analysis and implementation of variable step size adaptive algorithms , 1993, IEEE Trans. Signal Process..

[24]  Mahesh K. Mishra,et al.  A modified DSTATCOM topology with reduced VSI rating, DC link voltage, and filter size , 2013, 2013 International Conference on Clean Electrical Power (ICCEP).

[25]  Tyseer Aboulnasr,et al.  A robust variable step-size LMS-type algorithm: analysis and simulations , 1997, IEEE Trans. Signal Process..

[26]  José R. Espinoza,et al.  All-on-Chip dq-Frame Based D-STATCOM Control Implementation in a Low-Cost FPGA , 2013, IEEE Transactions on Industrial Electronics.

[27]  Pawan Sharma,et al.  Performance Investigation of Isolated Wind–Diesel Hybrid Power Systems With WECS Having PMIG , 2013, IEEE Transactions on Industrial Electronics.

[28]  Bhim Singh,et al.  Neural Network Based Conductance Estimation Control Algorithm for Shunt Compensation , 2014, IEEE Transactions on Industrial Informatics.

[29]  J A Barrado,et al.  Power-Quality Improvement of a Stand-Alone Induction Generator Using a STATCOM With Battery Energy Storage System , 2010, IEEE Transactions on Power Delivery.

[30]  S. Mishra,et al.  Permanent Magnet Synchronous Generator-Based Standalone Wind Energy Supply System , 2011, IEEE Transactions on Sustainable Energy.

[31]  Bhim Singh,et al.  Load Compensation for Diesel Generator-Based Isolated Generation System Employing DSTATCOM , 2011, IEEE Transactions on Industry Applications.