Development of a tele-stethoscope and its application in pediatric cardiology.

Over the years, many attempts have been made to develop special stethoscopes for the teaching of auscultation. The objective of this article is to report on the experience with the development and implementation of an electronic stethoscope and a virtual library of cardiac sounds. There were four stages to this project: (1) the building of the prototype to acquire, filter and amplify the cardiac sounds, (2) the development of a software program to record, reproduce and visualize them, (3) the testing of the prototype in a clinical scenario, and (4) the development of an internet site, to store and display the sounds collected. The first two stages are now complete. The prototype underwent an initial evaluation in a clinical scenario within the Unit and during virtual out-patient clinical sessions. One hundred auscultations were recorded during these tests. They were reviewed and discussed on-line by a panel of experience cardiologists during the sessions. Although the sounds were considered "satisfactory" for diagnostic purposes by the cardiology team, they identified some qualitative differences in the electronic recorded auscultations, such as a higher pitch of the recorded sounds. Prospective clinical studies are now being conducted to further evaluate the interference of the electronic device in the physicians' capability to diagnose different cardiac conditions. An internet site (www.caduceusvirtual.com.br/ auscultaped) was developed to host these cardiac auscultations. It is set as a library of cardiac sounds, catalogued by pathologies and already contains examples from auscultations of the majority of common congenital heart lesions, such as septal defects and valvar lesions.

[1]  F G Collins,et al.  An experimental electronic stethoscope for aircraft use. A preliminary report. SAM-TR-67-39. , 1967, [Technical report] SAM-TR. USAF School of Aerospace Medicine.

[2]  W. Fehske,et al.  Diagnosis and follow-up of congenital heart disease in children with the use of two-dimensional Doppler echocardiography. , 1984, Ultrasound in medicine & biology.

[3]  Michel Vacher,et al.  Information extraction from sound for medical telemonitoring , 2006, IEEE Transactions on Information Technology in Biomedicine.

[4]  Flenley Dc Diagnosis and follow-up of emphysema. , 1990 .

[5]  J Genest,et al.  Clinical comparison of acoustic and electronic stethoscopes and design of a new electronic stethoscope. , 1998, The American journal of cardiology.

[6]  Denis Abenson A high-fidelity electronic stethoscope. , 1971 .

[7]  R. Mcfee,et al.  Clinical auscultation skills in pediatric residents. , 2001, Pediatrics.

[8]  J. Belmont,et al.  Evaluation of remote stethoscopy for pediatric telecardiology. , 1995, Telemedicine journal : the official journal of the American Telemedicine Association.

[9]  Doppler echocardiography in non-invasive diagnosis of heart disease in infants and children , 1988, Indian journal of pediatrics.

[10]  A W Hahn On stethoscope design: a challenge for biomedical circuit designers. , 2001, Biomedical sciences instrumentation.

[11]  D Abelson A high-fidelity electronic stethoscope. , 1971, JAMA.

[12]  E. Victor,et al.  Phonomechanocardiographic Findings in Endomyocardial Fibrosis , 1984, Angiology.

[13]  N. Silverman,et al.  The current role of Doppler echocardiography in the diagnosis of heart disease in children. , 1989, Cardiology clinics.

[14]  J. Stevenson,et al.  Noninvasive determination of pressure gradients in children: two methods employing pulsed Doppler echocardiography. , 1984, Journal of the American College of Cardiology.

[15]  S. Menahem,et al.  The diagnosis of innocent murmurs in childhood , 2000, Cardiology in the Young.