Determining the Impact of Line Asymmetries on Network Voltage Unbalance based on Balanced Load Flow Studies

Determining the impact of the individual contributors to network voltage unbalance (VU) is a complex task due to the interaction between the sources of voltage unbalance in power systems. This becomes further complicated as the network itself contributes to network voltage unbalance when it is not symmetrical which is mostly the case in real networks. To account for the network asymmetry, the Technical Report IEC/TR 61000-3-13 which is used for the assessment of voltage unbalance emission limits applies a scaling factor Kue when apportioning the global allowance to end user consumers. Studies on the impact of the untransposed overhead lines on each and every individual busbar and on the overall network voltage unbalance are essential in: emission allocation studies, identification of power flow constraints, and in decision making related to future investments on VU mitigation. This paper proposes an effective methodology to determine the influence of different untransposed lines based on the results of balanced load flow studies. The methodology can be easily extended to obtain the influence of the other contributors as well.

[1]  Alexandra von Meier,et al.  UC Berkeley Sustainable Infrastructures Title A Linear Power Flow Formulation for Three-Phase Distribution Systems Permalink , 2016 .

[2]  B. Banerjee,et al.  Assessment of Voltage Unbalance , 2001, IEEE Power Engineering Review.

[3]  Angelo Baggini,et al.  Handbook of Power Quality , 2008 .

[4]  Nelson Kagan,et al.  A Power-Quality Index to Assess the Impact of Voltage Harmonic Distortions and Unbalance to Three-Phase Induction Motors , 2010, IEEE Transactions on Power Delivery.

[5]  S. Perera,et al.  A systematic approach towards evaluating voltage unbalance problem in interconnected sub-transmission networks: Separation of contribution by lines, loads and mitigation , 2008, 2008 13th International Conference on Harmonics and Quality of Power.

[6]  Z. Emin,et al.  Negative phase-sequence voltages on E&W transmission system , 2006, IEEE Transactions on Power Delivery.

[7]  Herwig Renner,et al.  Review of disturbance emissions assessment techniques , 2011 .

[8]  James S. Thorp,et al.  Three-phase linear state estimation using Phasor Measurements , 2013, 2013 IEEE Power & Energy Society General Meeting.

[9]  U. Jayatunga,et al.  Further contributions to the development of the technical report IEC/TR 61000-3-13:2008 on voltage unbalance management methodologies , 2013 .

[10]  D. P. Manjure,et al.  Impact of unbalance on power system harmonics , 2002, 10th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.02EX630).

[11]  S. Perera,et al.  Analysis of Network Asymmetry of Interconnected 66kV Sub-transmission Systems in relation to Voltage Unbalance , 2007, 2007 IEEE Power Engineering Society Conference and Exposition in Africa - PowerAfrica.

[12]  S. Perera,et al.  Voltage Unbalance Emission Assessment in Interconnected Power Systems , 2013, IEEE Transactions on Power Delivery.

[13]  S. Perera,et al.  Voltage Unbalance Emission Assessment in Radial Power Systems , 2012, IEEE Transactions on Power Delivery.