Accurate attenuation correction in SPECT without transmission measurements

The current trend in attenuation correction for SPECT is to measure and reconstruct the attenuation coefficient map using a transmission scan, performed either sequentially or simultaneously with the emission scan. This approach requires dedicated hardware and increases the cost (and in some cases the scanning time) required to produce a clinical SPECT image. Furthermore, if short focal length fan-beam collimators are used for transmission imaging, the projection data may be truncated, leading to errors in the attenuation coefficient map. Our goal is to obtain information about the attenuation distribution from only the measured emission data by exploiting the fact that only certain attenuation distributions are consistent with a given emission dataset. Ultimately this consistency information will either be used directly to compensate for attenuation or combined with the incomplete information from fan-beam transmission measurements to produce a more accurate attenuation coefficient map. The simulations and phantom studies performed in this investigation show that, in certain circumstances, the consistency conditions of the SPECT data can be used to produce an accurate estimate of the attenuation map without performing any transmission measurements.

[1]  M Hosoba,et al.  Automated body contour detection in SPECT: effects on quantitative studies. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  D R Gilland,et al.  Fast transmission CT for determining attenuation maps using a collimated line source, rotatable air-copper-lead attenuators and fan-beam collimation. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  Michael A. King,et al.  Segmentation of the body and lungs from Compton scatter and photopeak window data in SPECT: a Monte-Carlo investigation , 1996, IEEE Trans. Medical Imaging.

[4]  M Schwaiger,et al.  Comparison of americium-241 and technetium-99m as transmission sources for attenuation correction of thallium-201 SPECT imaging of the heart. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  Grant T. Gullberg,et al.  A comparison of Gd/Tc versus Tc/Tl simultaneous transmission and emission imaging using both single and triple detector fan-beam SPECT systems , 1994 .

[6]  G.L. Zeng,et al.  Non-uniform attenuation correction using simultaneous transmission and emission converging tomography , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[7]  Y. Censor,et al.  A New Approach to the Emission Computerized Tomography Problem: Simultaneous Calculation of Attenuation and Activity Coefficients , 1979, IEEE Transactions on Nuclear Science.

[8]  B F Hutton,et al.  A scanning line source for simultaneous emission and transmission measurements in SPECT. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  M. S. Kaplan,et al.  Preliminary Experience With The Photon History Generator Module Of A Public-domain Simulation System For Emission Tomography , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.

[10]  Thomas J. Hebert,et al.  A fully automated optimization algorithm for determining the 3-D patient contour from photo-peak projection data in SPECT , 1995, IEEE Trans. Medical Imaging.

[11]  Michael A. King,et al.  Determination of concave body outlines from SPECT projection data , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[12]  Paul L. Butzer,et al.  Fourier analysis and approximation , 1971 .

[13]  R J Jaszczak,et al.  Whole-body single-photon emission computed tomography using dual, large-field-of-view scintillation cameras , 1979, Physics in medicine and biology.

[14]  S. H. Manglos,et al.  Constrained IntraSPECT reconstruction from SPECT projections , 1993, 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference.

[15]  Frank Natterer,et al.  Determination of tissue attenuation in emission tomography of optically dense media , 1993 .

[16]  E C Frey,et al.  Simultaneous acquisition of emission and transmission data for improved thallium-201 cardiac SPECT imaging using a technetium-99m transmission source. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  A. Celler,et al.  SPECT transmission scans using multiple collimated line sources , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[18]  J R Perry,et al.  Correction of nonuniform attenuation in cardiac SPECT imaging. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  D. Bailey,et al.  Improved SPECT using simultaneous emission and transmission tomography. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[20]  F. Natterer The Mathematics of Computerized Tomography , 1986 .

[21]  G L DeNardo,et al.  Comparison of three boundary detection methods for SPECT using Compton scattered photons. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.