Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets.

Interface pressures were measured during ambulation with a normal total-surface weight-bearing suction socket and a vacuum-assisted socket. The vacuum-assisted socket has been shown to eliminate daily volume loss. Urethane liners were instrumented with five force-sensing resistors to measure positive pressures and one air pressure sensor at the distal end of the liner to document negative pressures. Nine unilateral transtibial amputees participated in the study. The vacuum-assisted socket created significantly lower positive-pressure impulse (42.8, 39.6 kPa x s) and peak pressures (83.5, 80.0 kPa) during the stance phase. The pressure impulse (-10.5, -13.3 kPa x s), average (-21.2, -26.5 kPa), and peak (-28.5, -36.3 kPa) negative pressures during swing phase were significantly greater in magnitude with the vacuum-assisted socket. We believe that lower positive pressures seen during stance using the vacuum-assisted socket reduces the fluid forced out and greater negative pressures seen during swing increases the amount of fluid drawn into the limb, thereby preventing volume loss.

[1]  E M Burgess,et al.  Clinical measurement of normal and shear stresses on a trans-tibial stump: Characteristics of wave-form shapes during walking , 1993, Prosthetics and orthotics international.

[2]  A G Crenshaw,et al.  Transcapillary fluid responses to lower body negative pressure. , 1993, Journal of applied physiology.

[3]  P K Commean,et al.  Below-knee residual limb shape change measurement and visualization. , 1998, Archives of physical medicine and rehabilitation.

[4]  E. Zimerson,et al.  Skin disorders in amputees. , 2000, Journal of the American Academy of Dermatology.

[5]  Koepke Gh,et al.  Effect of liner materials on interface pressures in below-knee prostheses. , 1970 .

[6]  G. Street,et al.  A comparison of trans-tibial amputee suction and vacuum socket conditions , 2001, Prosthetics and orthotics international.

[7]  Tb. Staats The UCLA total surface bearing suction below-knee prosthesis , 1987 .

[8]  T Länne,et al.  Dynamics of transcapillary fluid transfer and plasma volume during lower body negative pressure. , 1993, Acta physiologica Scandinavica.

[9]  S W Levy,et al.  Skin problems of the leg amputee. , 1980, Prosthetics and orthotics international.

[10]  M. Legro,et al.  Issues of importance reported by persons with lower limb amputations and prostheses. , 1999, Journal of rehabilitation research and development.

[11]  Levy Sw Amputees: skin problems and prostheses. , 1995 .

[12]  V. C. Roberts,et al.  Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis. , 1998, Medical engineering & physics.

[13]  L W Lamoreux,et al.  Evaluation of problems and needs of veteran lower-limb amputees in the San Francisco Bay Area during the period 1977-1980. , 1983, Journal of rehabilitation R&D.

[14]  G H Koepke,et al.  Effect of liner materials on interface pressures in below-knee prostheses. , 1970, Archives of physical medicine and rehabilitation.

[15]  R C Mains,et al.  Changes in total leg volume during lower body negative pressure. , 1969, Aerospace medicine.

[16]  J. Sanders,et al.  Effects of alignment changes on stance phase pressures and shear stresses on transtibial amputees: measurements from 13 transducer sites. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[17]  K. Parker,et al.  Effect of positive external pressure on calf volume and local venous haemodynamics. , 1977, Physics in medicine and biology.

[18]  P K Commean,et al.  Precision of surface measurements for below-knee residua. , 1996, Archives of physical medicine and rehabilitation.

[19]  G H Koepke,et al.  Negative pressures during swing phase in below-knee prostheses with rubber sleeve suspension. , 1975, Archives of physical medicine and rehabilitation.

[20]  S W Levy Amputees: skin problems and prostheses. , 1995, Cutis.

[21]  J E Sanders,et al.  Interface pressures and shear stresses at thirteen socket sites on two persons with transtibial amputation. , 1997, Journal of rehabilitation research and development.

[22]  J. Sanders,et al.  Skin response to repetitive mechanical stress: a new experimental model in pig. , 1998, Archives of physical medicine and rehabilitation.

[23]  E M Burgess,et al.  Interface shear stresses during ambulation with a below-knee prosthetic limb. , 1992, Journal of rehabilitation research and development.

[24]  A W Buis,et al.  Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a transtibial amputee , 1998, Prosthetics and orthotics international.

[25]  B M Persson,et al.  A clinical standard of stump measurement and classification in lower limb amputees , 1983, Prosthetics and orthotics international.

[26]  K. Berecek,et al.  Etiology of decubitus ulcers. , 1975, The Nursing clinics of North America.

[27]  S. Mellander,et al.  Effects of increased and decreased tissue pressure on haemodynamic and capillary events in cat skeletal muscle. , 1994, The Journal of physiology.

[28]  C H Daly,et al.  Interface pressures and shear stresses: Sagittal plane angular alignment effects in three trans-tibial amputee case studies , 1999, Prosthetics and orthotics international.

[29]  R. Wolthuis,et al.  Response of local vascular volumes to lower body negative pressure stress. , 1975, Aviation, space, and environmental medicine.

[30]  P J Holliday,et al.  Volume fluctuations in the residual limbs of lower limb amputees. , 1982, Archives of physical medicine and rehabilitation.