Bioinspired microneedle insertion for deep and precise skin penetration with low force: Why the application of mechanophysical stimuli should be considered.

A mosquito is known to precisely and easily insert its proboscis to the human skin by pressing down a labium and vibrating a fascicle bundle. Its advanced skin-piercing mechanisms indicate that skin resistance to the insertion of needle-like objects can be changed by the application of mechanophysical stimuli. Here, we characterize the effect of the application of mechanophysical stimuli on skin resistance to microneedle insertion to find clues for inserting a microneedle in a deep and precise fashion with low force. Microneedles with a diameter of 60-140µm are inserted at a velocity of 0.1-2.0mm/s to full-thickness porcine skins while either uniaxial/equibiaxial stretch of 0-20% or mechanical vibration at a frequency of 1 to 1000Hz and an amplitude of 1-10µm is applied to the skins as static or dynamic mechanophysical stimulus, respectively. The values of force and depth at two events of skin puncture and maximum penetration are measured to explore changes in skin resistance induced by the application of external stimuli. The static mechanophysical stimulus applied to the skin mainly affects the precision of microneedle insertion; the application of dynamic mechanophysical stimulus controls the value and deviation of skin resistance to microneedle insertion. The application of mechanophysical stimuli, inspired from a mosquito, therefore allows a microneedle to be deeply and easily inserted to the skin in a controlled way. The findings will have broad impacts on microneedle-mediated applications and lead to an in-depth understanding of skin biomechanics.

[1]  Allison M. Okamura,et al.  Force modeling for needle insertion into soft tissue , 2004, IEEE Transactions on Biomedical Engineering.

[2]  W. Yuan,et al.  Insertion and pull behavior of worker honeybee stinger , 2016 .

[3]  W R Walsh,et al.  Resistance forces acting on suture needles. , 2001, Journal of biomechanics.

[4]  Seiji Aoyagi,et al.  Biodegradable polymer needle with various tip angles and consideration on insertion mechanism of mosquito's proboscis , 2008 .

[5]  Pierre E. Dupont,et al.  Mechanics of Dynamic Needle Insertion into a Biological Material , 2010, IEEE Transactions on Biomedical Engineering.

[6]  H. Ioi,et al.  Effects of sliding velocity on friction: an in vitro study at extremely low sliding velocity approximating orthodontic tooth movement. , 2014, The Angle orthodontist.

[7]  G. Burch,et al.  DIFFERENTIAL ROLES OF LAYERS OF HUMAN EPIGASTRIC SKIN ON DIFFUSION RATE OF WATER , 1944 .

[8]  Robert Puers,et al.  A high aspect ratio SU-8 fabrication technique for hollow microneedles for transdermal drug delivery and blood extraction , 2010 .

[9]  H. Berg,et al.  Cats' Paws and Catapults: Mechanical Worlds of Nature and People , 1998 .

[10]  C Giorgi,et al.  Robot-assisted microscope for neurosurgery. , 1995, Journal of image guided surgery.

[11]  T. Prow,et al.  The effect of strain rate on the precision of penetration of short densely-packed microprojection array patches coated with vaccine. , 2010, Biomaterials.

[12]  Oliver A. Shergold,et al.  Experimental investigation into the deep penetration of soft solids by sharp and blunt punches, with application to the piercing of skin. , 2005, Journal of biomechanical engineering.

[13]  Gregor Cevc,et al.  Nanotechnology and the transdermal route: A state of the art review and critical appraisal. , 2010, Journal of controlled release : official journal of the Controlled Release Society.

[14]  B. Maharaj,et al.  SAMPLING VARIABILITY AND ITS INFLUENCE ON THE DIAGNOSTIC YIELD OF PERCUTANEOUS NEEDLE BIOPSY OF THE LIVER , 1986, The Lancet.

[15]  Lifeng Kang,et al.  Effect of microneedle geometry and supporting substrate on microneedle array penetration into skin. , 2013, Journal of pharmaceutical sciences.

[16]  Kozo Takayama,et al.  Region-Dependent Role of the Mucous/Glycocalyx Layers in Insulin Permeation Across Rat Small Intestinal Membrane , 2005, Pharmaceutical Research.

[17]  Hiroyuki Fujita,et al.  Fabrication of a Micro Needle for a Trace Blood Test , 2002 .

[18]  Zi-Long Zhao,et al.  Structures, properties, and functions of the stings of honey bees and paper wasps: a comparative study , 2015, Biology Open.

[19]  Ryan F. Donnelly,et al.  Microneedle arrays as transdermal and intradermal drug delivery systems: Materials science, manufacture and commercial development , 2016 .

[20]  F. Daffos,et al.  Fetal blood sampling via the umbilical cord using a needle guided by ultrasound report of 66 cases , 1983, Prenatal diagnosis.

[21]  B Finlay,et al.  Dynamic mechanical testing of human skin 'in vivo'. , 1970, Journal of biomechanics.

[22]  T. A. Thomas,et al.  Simulation of resistance forces acting on surgical needles , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[23]  F P T Baaijens,et al.  Monitoring the penetration process of single microneedles with varying tip diameters. , 2014, Journal of the mechanical behavior of biomedical materials.

[24]  Chengwei Wu,et al.  Measurement and Prediction of Insertion Force for the Mosquito Fascicle Penetrating into Human Skin , 2009 .

[25]  Juergen Lademann,et al.  Porcine ear skin: an in vitro model for human skin , 2007, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[26]  H. Barnes Thixotropy—a review , 1997 .

[27]  Mark R Prausnitz,et al.  Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force. , 2004, Journal of biomechanics.

[28]  I. H. Blank,et al.  Further observations on factors which influence the water content of the stratum corneum. , 1953, The Journal of investigative dermatology.

[29]  Dimitra Dodou,et al.  Buckling prevention strategies in nature as inspiration for improving percutaneous instruments: a review , 2016, Bioinspiration & biomimetics.

[30]  Rajni V. Patel,et al.  Needle insertion into soft tissue: a survey. , 2007, Medical engineering & physics.

[31]  T. Podder,et al.  In vivo motion and force measurement of surgical needle intervention during prostate brachytherapy. , 2006, Medical physics.

[32]  R Grahame,et al.  Elasticity of human skin in vivo. A study of the physical properties of the skin in rheumatoid arthritis and the effect of corticosteroids. , 1969, Annals of physical medicine.

[33]  Zhenguo Liu,et al.  Dissolving and biodegradable microneedle technologies for transdermal sustained delivery of drug and vaccine , 2013, Drug design, development and therapy.

[34]  H. Wulf,et al.  Epidermal thickness at different body sites: relationship to age, gender, pigmentation, blood content, skin type and smoking habits. , 2003, Acta dermato-venereologica.

[35]  Jung-Hwan Park,et al.  Biodegradable polymer microneedles: fabrication, mechanics and transdermal drug delivery. , 2005, Journal of controlled release : official journal of the Controlled Release Society.

[36]  Hyungil Jung,et al.  A patchless dissolving microneedle delivery system enabling rapid and efficient transdermal drug delivery , 2015, Scientific Reports.

[37]  A. Billich,et al.  Comparison of human skin or epidermis models with human and animal skin in in-vitro percutaneous absorption. , 2001, International journal of pharmaceutics.

[38]  K. Ita,et al.  Solid Microneedles for Transdermal Delivery of Amantadine Hydrochloride and Pramipexole Dihydrochloride , 2015, Pharmaceutics.

[39]  Y. Lee,et al.  Skin thickness of Korean adults , 2002, Surgical and Radiologic Anatomy.

[40]  Oliver A. Shergold,et al.  Mechanisms of deep penetration of soft solids, with application to the injection and wounding of skin , 2004, Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[41]  Hyungil Jung,et al.  Drawing Lithography: Three‐Dimensional Fabrication of an Ultrahigh‐Aspect‐Ratio Microneedle , 2010, Advanced materials.

[42]  F. Meurens,et al.  The immunology of the porcine skin and its value as a model for human skin. , 2015, Molecular immunology.

[43]  I. Lichtenstein,et al.  Local Anesthesia for Inguinal Hernia Repair Step‐by‐Step Procedure , 1994, Annals of surgery.

[44]  Sang-Hee Yoon,et al.  A mechanical analysis of woodpecker drumming and its application to shock-absorbing systems , 2011, Bioinspiration & biomimetics.

[45]  Seiji Aoyagi,et al.  Realistic imitation of mosquito's proboscis: Electrochemically etched sharp and jagged needles and their cooperative inserting motion , 2011 .

[46]  M K Ramasubramanian,et al.  Mechanics of a mosquito bite with applications to microneedle design , 2007, Bioinspiration & biomimetics.

[47]  T Jee,et al.  In vitro measurement of the mechanical properties of skin by nano/microindentation methods. , 2014, Journal of biomechanics.

[48]  Kent D. Butz,et al.  Prestress as an optimal biomechanical parameter for needle penetration. , 2012, Journal of biomechanics.