Experimental study of cold inflow effect on a small natural draft dry cooling tower

Abstract The heat rejection rate of natural draft dry cooling tower, as well as the operating performance of a power plant, can be affected by numerous ambient factors. The cold inflow is an unfavourable air turbulence at the top of the cooling tower and has a significant negative effect on the performance of natural draft cooling towers. In the present research, results are given for a 20 m high natural draft dry cooling tower experimental system tested at different ambient conditions. Several events of cold air incursion into the top of the cooling tower are identified and the detailed experimental data are presented. The experimental data show that this effect could seriously impair the thermal performance of the cooling tower. The water outlet temperature of the cooling tower has increased by as much as to 3 °C in these tests because of the cold inflow effect. The mechanism and the solution are discussed based on the experimental data. The findings in this paper can lay an important foundation for future small natural draft cooling tower design and operation.

[1]  Ali Turan,et al.  Experimental study regarding the evolution of temperature profiles inside wet cooling tower under crosswind conditions , 2014 .

[2]  Gq Amur,et al.  Experimental Study Of Wind Effects On The Airflow Of Natural Draft Wet Cooling Towers , 2010 .

[3]  Ephraim M Sparrow,et al.  Observed Flow Reversals and Measured-Predicted Nusselt Numbers for Natural Convection in a One-Sided Heated Vertical Channel , 1984 .

[4]  Zhiqiang Guan,et al.  Dirigible natural draft cooling tower in geothermal and solar power plant applications , 2009 .

[5]  Suoying He,et al.  Pre-cooling with Munters media to improve the performance of Natural Draft Dry Cooling Towers , 2013 .

[6]  K. Bourouni,et al.  Experimental Analysis of the Performance of a Mechanical Geothermal Water Cooling Tower in South Tunisia , 2013 .

[7]  M.F.M. Fahmy,et al.  Impact of ambient air temperature and heat load variation on the performance of air-cooled heat exchangers in propane cycles in LNG plants – Analytical approach , 2016 .

[8]  Boyin Zhang,et al.  A study of the unfavorable effects of wind on the cooling efficiency of dry cooling towers , 1995 .

[9]  Suoying He,et al.  Simulation of the UQ Gatton natural draft dry cooling tower , 2016 .

[10]  Suoying He,et al.  The influence of windbreak wall orientation on the cooling performance of small natural draft dry cooling towers , 2014 .

[11]  Kamel Hooman Dry cooling towers as condensers for geothermal power plants , 2010 .

[12]  Lei Chen,et al.  Effects of ambient winds on the thermo-flow performances of indirect dry cooling system in a power plant , 2013 .

[13]  M. Lemouari,et al.  Experimental investigation of the hydraulic characteristics of a counter flow wet cooling tower , 2011 .

[14]  Kai Wang,et al.  Experimental research of the guiding channels effect on the thermal performance of wet cooling towers subjected to crosswinds - Air guiding effect on cooling tower , 2010 .

[15]  D. G. Kröger,et al.  Air-cooled heat exchangers and cooling towers , 2005 .

[16]  E. Sparrow,et al.  Flow separation in a diverging conical duct: Effect of Reynolds number and divergence angle , 2009 .

[17]  Tao Ning,et al.  Experimental investigation on the performance of wet cooling towers with defects in power plants , 2015 .

[18]  J. H. Lee,et al.  A numerical simulation on recirculation phenomena of the plume generated by obstacles around a row of cooling towers , 2014 .

[19]  Xiaoxiao Li,et al.  Full scale experimental study of a small natural draft dry cooling tower for concentrating solar thermal power plant , 2017 .

[20]  Xiaoze Du,et al.  Influences of height to diameter ratios of dry-cooling tower upon thermo-flow characteristics of indirect dry cooling system , 2015 .

[21]  Yan Li,et al.  Numerical study on the cooling performance of dry cooling tower with vertical two-pass column radiators under crosswind , 2015 .

[22]  E. J. Pring,et al.  Cooling Towers: Principles and Practice , 1990 .

[23]  Liu Pei-qing Experimental Researches of the Effect of Environmental Wind on Thermal Recirculation Under the Tower of Direct Air Cooled System , 2008 .

[24]  M. M. Rahman,et al.  Experimental Study Of Cold Inflow AndIts Effect On Draft Of A Chimney , 2012 .

[25]  Phillip L. Gould,et al.  Cooling Tower Structures , 1998 .

[26]  Hal Gurgenci,et al.  Solar enhanced natural draft dry cooling tower for geothermal power applications , 2012 .

[27]  Sivakumar Kumaresan,et al.  Effect of cold inflow on chimney height of natural draft cooling towers , 2012 .

[28]  Yuanshen Lu,et al.  Small natural draft dry cooling towers for renewable power plants , 2015 .

[29]  Suoying He,et al.  Experimental study of crosswind effects on the performance of small cylindrical natural draft dry cooling towers , 2015 .

[30]  Yan Li,et al.  Effect mechanism of air deflectors on the cooling performance of dry cooling tower with vertical delta radiators under crosswind , 2015 .

[31]  R. S. Scorer,et al.  An experimental study of cold inflow into chimneys , 1967 .

[32]  Kenneth E. Torrance,et al.  Experiments on Chimney-Enhanced Free Convection , 1999 .

[33]  S. Ellison,et al.  Quantifying uncertainty in analytical measurement , 2000 .

[34]  Fu Xiao,et al.  Effects of discharge recirculation in cooling towers on energy efficiency and visible plume potential of chilling plants , 2012 .

[35]  Xiaoze Du,et al.  Dimensional characteristics of wind effects on the performance of indirect dry cooling system with vertically arranged heat exchanger bundles , 2013 .

[36]  Kenneth E. Torrance,et al.  Experimental and Numerical Studies of Cold Inflow at the Exit of Buoyant Channel Flows , 1987 .

[37]  Detlev G. Kröger,et al.  The effect of the heat exchanger arrangement and wind-break walls on the performance of natural draft dry-cooling towers subjected to cross-winds , 1995 .

[38]  Md. Mizanur Rahman,et al.  A method to achieve robust aerodynamics and enhancement of updraft in natural draft dry cooling towers , 2009 .