A novel approach for optimizing dead time of extra high voltage transmission lines

Reducing dead time of high voltage power transmission lines is one of the most important issues in power system protection. Besides, need for reducing the dead time is a matter of grave concern to increase voltage level of power transmission lines and insulation coordination. In this paper, different methods for decreasing the capacitive coupling and consequently reducing the dead time of power transmission lines are compared. This leads to faster quenching of secondary arc and limit the transient over voltage. Moreover, a novel hybrid approach is presented for reducing dead time of power transmission lines and faster quenching of secondary arc current. Simulations performed in electromagnetic transient program are performed for different cases. Simulation results show that dead time is reduced appropriately by proposed method.

[1]  Harold A. Peterson,et al.  A Method for Reducing Dead Time for Single-Phase Reclosing in EHV Transmission , 1969 .

[2]  O. P. Malik,et al.  Experimental Results of a Supplementary Technique for Auto-Reclosing EHV/UHV Transmission Lines , 2002, IEEE Power Engineering Review.

[3]  E. Rosolowski,et al.  Arc effect on single-phase reclosing time of a UHV power transmission line , 2004, IEEE Transactions on Power Delivery.

[4]  J.G. Kassakian The effects of non-transposition and earth return frequency dependence on transients due to high speed reclosing , 1976, IEEE Transactions on Power Apparatus and Systems.

[5]  Z.M. Radojevic,et al.  New one terminal digital algorithm for adaptive reclosing and fault distance calculation on transmission lines , 2006, IEEE Transactions on Power Delivery.

[6]  B. J. Ware,et al.  Compensation Scheme for Single-Pole Switching on Untransposed Transmission Lines , 1978, IEEE Transactions on Power Apparatus and Systems.

[7]  Nagy I. Elkalashy,et al.  An adaptive single pole autoreclosure based on zero sequence power , 2007 .

[8]  A. T. Johns,et al.  An Alternative Approach to Adaptive Single-Pole Auto Reclosing in High-Voltage Transmission Systems Based on Variable Dead Time Control , 2001, IEEE Power Engineering Review.

[9]  Z.M. Radojevic,et al.  New Digital Algorithm for Adaptive Reclosing Based on the Calculation of the Faulted Phase Voltage Total Harmonic Distortion Factor , 2007, IEEE Transactions on Power Delivery.

[10]  Nouredine Hadjsaid,et al.  Reducing dead time for single-phase auto-reclosing on a series-capacitor compensated transmission line , 2000 .

[11]  C. Eng,et al.  Adaptive reclosure of HV overhead lines , 1996, Proceedings of 1996 Transmission and Distribution Conference and Exposition.

[12]  W. Peterson,et al.  The Application of High-Speed Grounding Switches for Single-Pole Reclosing on 500 kV Power Systems , 1981, IEEE Transactions on Power Apparatus and Systems.

[13]  A. T. Johns,et al.  Improved techniques for modelling fault arcs an faulted EHV transmission systems , 1994 .

[14]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.