Use of Point-of-Care Ultrasound to Guide Pediatric Gastrostomy Tube Replacement in the Emergency Department

Abstract The presentation of a pediatric patient to the emergency department for a malfunctioning or dislodged gastrostomy tube (G-tube) is not uncommon. As such, these tubes are often replaced at the bedside. Improper placement can result in a number of complications, including perforation, fistula tract formation, peritonitis, and sepsis. The current criterion standard method to confirm proper G-tube placement is contrast-enhanced radiography. However, point-of-care ultrasound may be an alternative method to guide and confirm pediatric G-tube replacement in the emergency department. We report a series of cases on this novel point-of-care ultrasound application.

[1]  Jennifer N. Cooper,et al.  Emergency Department Visits and Readmissions among Children after Gastrostomy Tube Placement. , 2016, The Journal of pediatrics.

[2]  D. Partrick,et al.  National Trends and Outcomes of Pediatric Gastrostomy Tube Placement , 2014, Journal of pediatric gastroenterology and nutrition.

[3]  S. Kłęk,et al.  Ultrasound-guided percutaneous 'push-introducer' gastrostomy is a valuable method for accessing the gastrointestinal tract. , 2014, Nutricion hospitalaria.

[4]  V. Lohsiriwat Percutaneous endoscopic gastrostomy tube replacement: A simple procedure? , 2013, World journal of gastrointestinal endoscopy.

[5]  B. Kerrey,et al.  Gastrostomy tube replacement in a pediatric ED: frequency of complications and impact of confirmatory imaging. , 2012, The American journal of emergency medicine.

[6]  J. Naiditch,et al.  Postoperative complications in children undergoing gastrostomy tube placement. , 2010, Journal of laparoendoscopic & advanced surgical techniques. Part A.

[7]  Teresa S. Wu,et al.  Ultrasound can accurately guide gastrostomy tube replacement and confirm proper tube placement at the bedside. , 2009, The Journal of emergency medicine.

[8]  F. Klebl,et al.  Ultrasound-guided percutaneous endoscopic gastrostomy in patients with negative diaphanoscopy , 2007, Endoscopy.

[9]  D. Sanders,et al.  Ultrasound guidance in the placement of a percutaneous endoscopic gastrostomy (PEG): an adjuvant technique in patients with abdominal wall varices? , 2005, Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver.

[10]  M. Manns,et al.  Percutaneous sonographic gastrostomy: method, indications, and problems , 1998, American Journal of Gastroenterology.

[11]  S. Isaacson,et al.  Ultrasound guidance in percutaneous gastrostomy and gastrojejunostomy. , 1995, Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes.

[12]  B. Skjoldbye,et al.  Percutaneous gastrostomy guided by ultrasound and fluoroscopy. , 1995, Acta radiologica.

[13]  Harrison Cr,et al.  Ultrasound-assisted percutaneous endoscopic gastrostomy in a patient with advanced ovarian carcinoma and recurrent intestinal obstruction , 1993 .

[14]  T. E. Little,et al.  Two fatal complications related to gastrostomy "button" placement. , 1992, Gastrointestinal endoscopy.

[15]  J. Scolapio Gastrostomy Tube–Related Complaints in the Pediatric Emergency Department: Identifying Opportunities for Improvement , 2010 .