Intraoperative use of transoesophageal Doppler to predict response to volume expansion in infants and neonates.

BACKGROUND Volume expansion (VE) in neonates or infants during volatile anaesthesia may lead to fluid overload if inappropriate. Transoesophageal Doppler (TED), a non-invasive cardiac output monitoring technique, can provide a comprehensive estimation of the volaemic status. We evaluated whether intraoperative TED-derived parameters can predict volume responsiveness. METHODS Neonates and infants under general anaesthesia without myocardial dysfunction were prospectively included when the attending anaesthetist, blinded to TED measurements, decided to provide VE based on clinical appreciation and standard monitoring data. Standard and TED-derived data were recorded before and after VE. After VE, patients were classified as responders and non-responders, if their indexed stroke volume (iSV) increased by more than 15% or not, respectively. The attending anaesthetist assessment of VE responsiveness was recorded at the end of VE. RESULTS Fifty patients aged 42 (4) post-conceptional weeks were included, among which 26 (52%) were responders. Baseline iSV was the only parameter associated with VE responsiveness. Baseline iSV was fairly correlated with VE-induced changes in iSV (ρ=-0.64) and was associated with an area under the receiver operating characteristic curve of 0.90 (0.80, 0.99). Using a cut-off of 25 ml m(-2), baseline iSV predicted volume responsiveness with a sensitivity of 92% and a specificity of 83%. Attending anaesthetists' assessment of VE effectiveness agreed only moderately with TED measurements of iSV changes. CONCLUSIONS TED-derived iSV measurement during volatile anaesthesia is useful to predict and follow VE responsiveness in neonates and infants without myocardial dysfunction.

[1]  C. Mottolese,et al.  Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography. , 2011, British journal of anaesthesia.

[2]  Ji Yeon Lee,et al.  Respiratory Variation in Aortic Blood Flow Velocity as a Predictor of Fluid Responsiveness in Children After Repair of Ventricular Septal Defect , 2010, Pediatric Cardiology.

[3]  R. Cavallazzi,et al.  Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature* , 2009, Critical care medicine.

[4]  M. Singer Oesophageal Doppler , 2009, Current opinion in critical care.

[5]  E. Moretti,et al.  Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting , 2009, Anesthesia and analgesia.

[6]  F. Sztark,et al.  Uncalibrated pulse contour-derived stroke volume variation predicts fluid responsiveness in mechanically ventilated patients undergoing liver transplantation. , 2008, British journal of anaesthesia.

[7]  M. Cannesson,et al.  Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. , 2008, British journal of anaesthesia.

[8]  Michael Baram,et al.  Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. , 2008, Chest.

[9]  F. Michel,et al.  Experience with remifentanil–sevoflurane balanced anesthesia for abdominal surgery in neonates and children less than 2 years , 2008, Paediatric anaesthesia.

[10]  G. de Martino,et al.  Assessment of fluid-responsiveness parameters for off-pump coronary artery bypass surgery: a comparison among LiDCO, transesophageal echochardiography, and pulmonary artery catheter. , 2008, Journal of cardiothoracic and vascular anesthesia.

[11]  F. Michard,et al.  Online Monitoring of Pulse Pressure Variation to Guide Fluid Therapy After Cardiac Surgery , 2008, Anesthesia and analgesia.

[12]  S. Essouri,et al.  Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children , 2008, Intensive Care Medicine.

[13]  Cinoo Kim,et al.  Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness. , 2007, British journal of anaesthesia.

[14]  Maxime Cannesson,et al.  Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room. , 2007, Anesthesiology.

[15]  Karim Bendjelid,et al.  Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients , 2007, Intensive Care Medicine.

[16]  G. Natalini,et al.  Arterial Versus Plethysmographic Dynamic Indices to Test Responsiveness for Testing Fluid Administration in Hypotensive Patients: A Clinical Trial , 2006, Anesthesia and analgesia.

[17]  F. Pruvot,et al.  Non-invasive prediction of fluid responsiveness during major hepatic surgery. , 2006, British journal of anaesthesia.

[18]  G. Marx,et al.  Correlation of oxygen delivery with central venous oxygen saturation, mean arterial pressure and heart rate in piglets , 2006, Paediatric anaesthesia.

[19]  M. Pinsky,et al.  Passive leg raising predicts fluid responsiveness in the critically ill* , 2006, Critical care medicine.

[20]  D. Benhamou,et al.  The Influence of Tidal Volume on the Dynamic Variables of Fluid Responsiveness in Critically Ill Patients , 2006, Anesthesia and analgesia.

[21]  S. Fleming,et al.  Intraoperative oesophageal Doppler guided fluid management shortens postoperative hospital stay after major bowel surgery. , 2005, British journal of anaesthesia.

[22]  M. Pinsky,et al.  Esophageal Doppler monitoring predicts fluid responsiveness in critically ill ventilated patients , 2005, Intensive Care Medicine.

[23]  P. Lange,et al.  Doppler Flow Parameters of Left Ventricular Filling in Infants: How Long Does It Take for the Maturation of the Diastolic Function in a Normal Left Ventricle to Occur? , 2004, Pediatric Cardiology.

[24]  Clifford Kavinsky,et al.  Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects , 2004, Critical care medicine.

[25]  J. Poelaert,et al.  Accuracy and repeatability of pediatric cardiac output measurement using Doppler: 20-year review of the literature , 2003, Intensive Care Medicine.

[26]  Peter Lamm,et al.  Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function , 2003, Critical care medicine.

[27]  P. Glass,et al.  Goal-directed Intraoperative Fluid Administration Reduces Length of Hospital Stay after Major Surgery , 2002, Anesthesiology.

[28]  E. Wodey,et al.  Accuracy and limitations of continuous oesophageal aortic blood flow measurement during general anaesthesia for children: comparison with transcutaneous echography‐Doppler , 2001, Paediatric anaesthesia.

[29]  A. Perel,et al.  Stroke Volume Variation as a Predictor of Fluid Responsiveness in Patients Undergoing Brain Surgery , 2001, Anesthesia and analgesia.

[30]  J. Teboul,et al.  Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. , 2001, Chest.

[31]  S. Tibby,et al.  Are transoesophageal Doppler parameters a reliable guide to paediatric haemodynamic status and fluid management? , 2001, Intensive Care Medicine.

[32]  S. Tibby,et al.  Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: Derivation of cardiac output , 2000, Critical care medicine.

[33]  P. Nuntnarumit,et al.  Blood pressure measurements in the newborn. , 1999, Clinics in perinatology.

[34]  K. Harada,et al.  Serial echocardiographic and Doppler evaluation of left ventricular systolic performance and diastolic filling in premature infants. , 1999, Early human development.

[35]  S. Tibby,et al.  Clinicians’ abilities to estimate cardiac index in ventilated children and infants , 1997, Archives of disease in childhood.

[36]  M. Singer,et al.  Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial , 1997, BMJ.

[37]  E. Wodey,et al.  Comparative Hemodynamic Depression of Sevoflurane versus Halothane in Infants: An Echocardiographic Study , 1997, Anesthesiology.

[38]  E. Mcclean,et al.  The peri‐operative use of the oesophageal Doppler monitor in patients undergoing coronary artery revascularisation#A comparison with the continuous cardiac output monitor , 1997, Anaesthesia.

[39]  M. Kluckow,et al.  Relationship between blood pressure and cardiac output in preterm infants requiring mechanical ventilation. , 1996, The Journal of pediatrics.

[40]  C. Harkin,et al.  Cardiovascular responses to sevoflurane: a review. , 1995, Anesthesia and analgesia.

[41]  T. Ebert,et al.  Neurocirculatory Responses to Sevoflurane in Humans: A Comparison to Desflurane , 1995, Anesthesiology.

[42]  J. Lerman,et al.  The Pharmacology of Sevoflurane in Infants and Children , 1994, Anesthesiology.

[43]  E. Bennett,et al.  Noninvasive optimization of left ventricular filling using esophageal Doppler , 1991, Critical care medicine.

[44]  A. Webb,et al.  Effects of alterations in left ventricular filling, contractility, and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects , 1991, Critical care medicine.

[45]  J. Kampine,et al.  Influence of volatile anesthetics on myocardial contractility in vivo: desflurane versus isoflurane. , 1991, Anesthesiology.

[46]  J. Kampine,et al.  Effects of nitrous oxide on myocardial contractility as evaluated by the preload recruitable stroke work relationship in chronically instrumented dogs. , 1990, Anesthesiology.

[47]  C H Bauer,et al.  Care of the high-risk neonate. , 1975, Pediatric annals.

[48]  R. Venn,et al.  Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. , 2002, British journal of anaesthesia.

[49]  D. Chemla,et al.  Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. , 2000, American journal of respiratory and critical care medicine.

[50]  A. Fanaroff,et al.  Care of the High-Risk Neonate , 1986 .