The Narcotrend monitor.

The Narcotrend (MonitorTechnik, Bad Bramstedt, Germany) is an EEG monitor designed to measure the depth of anaesthesia. It has been developed at the University Medical School of Hannover, Germany, has been commercially available for 5 years and has meanwhile received US Food and Drug Administration approval. The Narcotrend algorithm is based on pattern recognition of the raw electroencephalogram (EEG) and classifies the EEG traces into different stages from A (awake) to F (increasing burst suppression down to electrical silence). The newest Narcotrend software version includes a dimensionless Narcotrend index from 100 (awake) to 0 (electrical silence). The raw EEG signal can be recorded by standard electrocardiogram electrodes for single- and double-channel registration. The Narcotrend monitor provides a vast amount of information: the actual Narcotrend stage and index, the trend ('cerebrogram'), the raw EEG signal and a power spectrum and several derived EEG parameters. Multiple clinical and validation studies are available for the Narcotrend monitor, including comparisons with the BIS monitor (Aspect Medical Systems, Natick, USA).

[1]  S. Kreuer,et al.  The Narcotrend™– a new EEG monitor designed to measure the depth of anaesthesia A comparison with bispectral index monitoring during propofol-remifentanil-anaesthesia , 2001, Der Anaesthesist.

[2]  S. Kreuer,et al.  Narcotrend Monitoring Allows Faster Emergence and a Reduction of Drug Consumption in Propofol–Remifentanil Anesthesia , 2003, Anesthesiology.

[3]  B Schultz,et al.  Automatic Classification Algorithms of the EEG Monitor Narcotrend for Routinely Recorded EEG Data from General Anaesthesia: a Validation Study , 2002, Biomedizinische Technik. Biomedical engineering.

[4]  A. Schultz,et al.  Der Narcotrend®-Monitor , 2003, Der Anaesthesist.

[5]  P. Bischoff,et al.  Narcotrend, Bispectral Index, and Classical Electroencephalogram Variables During Emergence from Propofol/Remifentanil Anesthesia , 2002, Anesthesia and analgesia.

[6]  R. Larsen,et al.  Narcotrend-Stadien und endexspiratorische Desflurankonzentrationen , 2002, Der Anaesthesist.

[7]  J. Bruhn,et al.  Narcotrend or Bispectral Index Monitoring During Desflurane-Remifentanil Anesthesia: A Comparison with a Standard Practice Protocol , 2005, Anesthesia and analgesia.

[8]  J. Bruhn,et al.  Comparability of Narcotrend index and bispectral index during propofol anaesthesia. , 2004 .

[9]  Thomas Standl,et al.  Narcotrend® and Bispectral Index® Monitor Are Superior to Classic Electroencephalographic Parameters for the Assessment of Anesthetic States during Propofol-Remifentanil Anesthesia , 2003, Anesthesiology.

[10]  A. Loomis,et al.  Cerebral states during sleep, as studied by human brain potentials , 1937 .

[11]  R. Bender,et al.  Classification of EEG Signals into General Stages of Anesthesia in Real-Time Using Autoregressive Models , 1993 .

[12]  Michael P. Windham,et al.  Information and classification: Concepts, methods and applications , 1995 .

[13]  R. Larsen,et al.  Narcotrend-EEG-Monitoring bei total intravenöser Anästhesie , 2002, Der Anaesthesist.