Usability Evaluation of a Blood Glucose Monitoring System With a Spill-Resistant Vial, Easier Strip Handling, and Connectivity to a Mobile App

Background: Proper management of diabetes mellitus requires regular self-monitoring of blood glucose (SMBG). This research evaluated the usability of the Accu-Chek® Guide Meter that includes a spill-resistant vial, easier strip handling, and wireless connectivity to a mobile app. Methods: A total of 197 participants were allowed to experience typical blood glucose testing tasks on the Accu-Chek Guide Meter, review data such as last result, patterns, and target percentage on the meter and on the mobile app, and then evaluate their experience through a human factors usability survey. Participants used a 6-point agree/disagree scale to rate 34 market statement questions. Results: The results of a Pearson chi-square proportions test for each of the 34 market statement questions showed a significant difference (P < .0001) between the disagree responses (1-3) and agree responses (4-6). An overwhelming majority of participants found all aspects of the system, including the test strips, strip vial, and data analysis on the meter and the mobile app, to be a good fit for their lifestyle and to provide a better testing experience. Conclusions: This study found superior usability of the new meter system over the participants’ current meters in both the United States and France.

[1]  Ronald Tamler,et al.  An evaluation of diabetes self-management applications for Android smartphones , 2012, Journal of telemedicine and telecare.

[2]  R. Colagiuri,et al.  The Quality of Self‐monitoring of Blood Glucose , 1990, Diabetic medicine : a journal of the British Diabetic Association.

[3]  Aparna Srinivasan,et al.  Evaluation of a Blood Glucose Monitoring System with Automatic High- and Low-Pattern Recognition Software in Insulin-Using Patients: Pattern Detection and Patient-Reported Insights , 2013, Journal of diabetes science and technology.

[4]  Christopher G. Parkin,et al.  Effective Use of Structured Self-Management of Blood Glucose in Type 2 Diabetes: Lessons From the STeP Study , 2011, Clinical Diabetes.

[5]  R. Kaye,et al.  An overview of human factors engineering at CDRH in the safety and effectiveness of blood glucose meters. , 2002, Diabetes technology & therapeutics.

[6]  David M. Smith,et al.  Evidence Linking Hypoglycemic Events to an Increased Risk of Acute Cardiovascular Events in Patients With Type 2 Diabetes , 2011, Diabetes Care.

[7]  Eric Bergman,et al.  Introduction to Human Factors , 2012, Journal of diabetes science and technology.

[8]  C. Ng,et al.  Barriers and facilitators to self-monitoring of blood glucose in people with type 2 diabetes using insulin: a qualitative study , 2014, Patient preference and adherence.

[9]  Gunn B B Kristensen,et al.  Standardized evaluation of nine instruments for self-monitoring of blood glucose. , 2008, Diabetes technology & therapeutics.

[10]  Ann Blandford,et al.  7 Themes for guiding situated ergonomic assessments of medical devices: a case study of an inpatient glucometer. , 2014, Applied ergonomics.

[11]  Elizabeth Selvin,et al.  Trends in Prevalence and Control of Diabetes in the United States, 1988–1994 and 1999–2010Trends in Prevalence and Control of Diabetes in the United States , 2014 .

[12]  A. Briggs,et al.  Self-monitoring Blood Glucose (SMBG): Now and the Future , 2004 .

[13]  David Meister,et al.  Behavioral Analysis and Measurement Methods , 1985 .