Preliminary Investigations into Macroscopic Attenuated Total Reflection—Fourier Transform Infrared Imaging of Intact Spherical Domains: Spatial Resolution and Image Distortion

This paper describes preliminary investigations into the spatial resolution of macro attenuated total reflection (ATR) Fourier transform infrared (FT-IR) imaging and the distortions that arise when imaging intact, convex domains, using spheres as an extreme example. The competing effects of shallow evanescent wave penetration and blurring due to finite spatial resolution meant that spheres within the range 20–140 μm all appeared to be approximately the same size (∼30–35 μm) when imaged with a numerical aperture (NA) of ∼0.2. A very simple model was developed that predicted this extreme insensitivity to particle size. On the basis of these studies, it is anticipated that ATR imaging at this NA will be insensitive to the size of intact highly convex objects. A higher numerical aperture device should give a better estimate of the size of small spheres, owing to superior spatial resolution, but large spheres should still appear undersized due to the shallow sampling depth. An estimate of the point spread function (PSF) was required in order to develop and apply the model. The PSF was measured by imaging a sharp interface; assuming an Airy profile, the PSF width (distance from central maximum to first minimum) was estimated to be ∼20 and 30 μm for IR bands at 1600 and 1000 cm−1, respectively. This work has two significant limitations. First, underestimation of domain size only arises when imaging intact convex objects; if surfaces are prepared that randomly and representatively section through domains, the images can be analyzed to calculate parameters such as domain size, area, and volume. Second, the model ignores reflection and refraction and assumes weak absorption; hence, the predicted intensity profiles are not expected to be accurate; they merely give a rough estimate of the apparent sphere size. Much further work is required to place the field of quantitative ATR-FT-IR imaging on a sound basis.

[1]  P. R. Graves,et al.  Novel applications of Raman microscopy , 1986, Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences.

[2]  Photometric Considerations in the Design and Use of Infrared Microscope Accessories , 1987 .

[3]  R. C. Reeder,et al.  Fourier transform spectroscopic imaging using an infrared focal-plane array detector. , 1995, Analytical chemistry.

[4]  Andre J. Sommer,et al.  Attenuated Total Internal Reflection Microspectroscopy of Isolated Particles: An Alternative Approach to Current Methods , 1999 .

[5]  Andre J. Sommer,et al.  Attenuated Total Internal Reflection Infrared Mapping Microspectroscopy of Soft Materials , 2000 .

[6]  Jack L. Koenig,et al.  Comparison of the FT-IR Mapping and Imaging Techniques Applied to Polymeric Systems , 2000 .

[7]  C. Marcott,et al.  Attenuated Total Internal Reflection Infrared Mapping Microspectroscopy Using an Imaging Microscope , 2001 .

[8]  Rohit Bhargava,et al.  Novel Route to Faster Fourier Transform Infrared Spectroscopic Imaging , 2001 .

[9]  S. Kazarian,et al.  Combined Application of Imaging Methods for the Characterization of a Polymer Blend , 2002 .

[10]  Richard A. Crocombe,et al.  FT-IR imaging of polymers: an industrial appraisal , 2002 .

[11]  S. Kazarian,et al.  New Opportunities in Micro- and Macro-Attenuated Total Reflection Infrared Spectroscopic Imaging: Spatial Resolution and Sampling Versatility , 2003, Applied spectroscopy.

[12]  S. Kazarian,et al.  Visualisation of the heterogeneous water sorption in a pharmaceutical formulation under controlled humidity via FT-IR imaging , 2004 .

[13]  Jaap van der Weerd,et al.  Combined approach of FTIR imaging and conventional dissolution tests applied to drug release. , 2004, Journal of controlled release : official journal of the Controlled Release Society.

[14]  Sergei G. Kazarian,et al.  Validation of Macroscopic Attenuated Total Reflection-Fourier Transform Infrared Imaging to Study Dissolution of Swelling Pharmaceutical Tablets , 2004, Applied spectroscopy.

[15]  Sergei G. Kazarian,et al.  Spectroscopic Imaging of Compacted Pharmaceutical Tablets , 2005 .

[16]  I. W. Levin,et al.  Fourier transform infrared vibrational spectroscopic imaging: integrating microscopy and molecular recognition. , 2005, Annual review of physical chemistry.

[17]  D. Williams,et al.  Fourier Transform Infrared Imaging of Human Hair with a High Spatial Resolution without the Use of a Synchrotron , 2005, Applied spectroscopy.

[18]  S. Kazarian,et al.  Fourier transform infrared imaging for high-throughput analysis of pharmaceutical formulations. , 2005, Journal of combinatorial chemistry.

[19]  C. Ricci,et al.  Combining the Tape-Lift Method and Fourier Transform Infrared Spectroscopic Imaging for Forensic Applications , 2006, Applied spectroscopy.

[20]  A. Foltynowicz,et al.  Absorption Spectrometry by Narrowband Light in Optically Saturated and Optically Pumped Collision and Doppler Broadened Gaseous Media under Arbitrary Optical Thickness Conditions , 2006, Applied spectroscopy.

[21]  E. Neil Lewis,et al.  Instrumentation for FT-IR Imaging , 2006 .

[22]  S. Kazarian,et al.  Attenuated Total Reflection Fourier Transform Infrared Imaging with Variable Angles of Incidence: A Three-Dimensional Profiling of Heterogeneous Materials , 2007, Applied spectroscopy.

[23]  C. Ricci,et al.  Chemical Imaging of Latent Fingerprint Residues , 2007, Applied spectroscopy.

[24]  Curtis Marcott,et al.  Infrared Microspectroscopic Imaging Using a Large Radius Germanium Internal Reflection Element and a Focal Plane Array Detector , 2007, Applied spectroscopy.

[26]  Loa P. Traxler,et al.  Micro-Attenuated Total Reflection Spectral Imaging in Archaeology: Application to Maya Paint and Plaster Wall Decorations , 2008, Applied spectroscopy.