Injectable Sensors Based on Passive Rectification of Volume-Conducted Currents

Sensing implants that can be deployed by catheterization or by injection are preferable over implants requiring invasive surgery. However, present powering methods for active implants and present interrogation methods for passive implants require bulky parts within the implants that hinder the development of such minimally invasive devices. In this article, we propose a novel approach that potentially enables the development of passive sensing systems overcoming the limitations of previous implantable sensing systems in terms of miniaturization. In this approach implants are shaped as thread-like devices suitable for implantation by injection. Their basic structure consists of a thin elongated body with two electrodes at opposite ends and a simple and small circuit made up of a diode, a capacitor and a resistor. The interrogation method to obtain measurements from the implants consists in applying innocuous bursts of high frequency (≥1 MHz) alternating current that reach the implants by volume conduction and in capturing and processing the voltage signals that the implants produce after the bursts. As proof-of-concept, and for illustrating how to put in practice this novel approach, here we describe the development and characterization of a system for measuring the conductivity of tissues surrounding the implant. We also describe the implementation and the in vitro validation of a 0.95 mm-thick, flexible injectable implant made of off-the-shelf components. For conductivities ranging from about 0.2 to 0.8 S/m, when compared to a commercial conductivity meter, the accuracy of the implemented system was about ±10%.

[1]  Antoni Ivorra,et al.  Two-Port Networks to Model Galvanic Coupling for Intrabody Communications and Power Transfer to Implants , 2018, 2018 IEEE Biomedical Circuits and Systems Conference (BioCAS).

[2]  Boris Rubinsky,et al.  Linear Superposition Electrical Impedance Tomography Imaging With Multiple Electrical/Biopsy Probes , 2009, IEEE Transactions on Biomedical Engineering.

[3]  Paul P Breen,et al.  BION microstimulators: a case study in the engineering of an electronic implantable medical device. , 2011, Medical engineering & physics.

[4]  J. Varon,et al.  Congestive heart failure and pulmonary edema for the emergency physician. , 1995, The Journal of emergency medicine.

[5]  Bruce C. Towe,et al.  Wireless impedance measurements for monitoring peripheral vascular disease , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  C. Collins,et al.  Miniature passive pressure transensor for implanting in the eye. , 1967, IEEE transactions on bio-medical engineering.

[7]  Babak Ziaie,et al.  New and Emerging Energy Sources for Implantable Wireless Microdevices , 2015, IEEE Access.

[8]  David Djajaputra,et al.  RF / Microwave Interaction with Biological Tissues , 2006 .

[9]  Konstantina S. Nikita,et al.  A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables , 2017, IEEE Transactions on Biomedical Engineering.

[10]  W. Olson,et al.  Feasibility of Using an Implantable System to Measure Thoracic Congestion in an Ambulatory Chronic Heart Failure Canine Model , 2005, Pacing and clinical electrophysiology : PACE.

[11]  F. Oliva,et al.  Monitoring Intrathoracic Impedance with an Implantable Defibrillator Reduces Hospitalizations in Patients with Heart Failure , 2009, Pacing and clinical electrophysiology : PACE.

[12]  Ronald Brazg,et al.  A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II , 2018, Diabetes technology & therapeutics.

[13]  A. Ahlbom Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) , 1998 .

[14]  国際非電離放射線防護委員会 ICNIRP statement on the "Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz)". , 2009, Health physics.

[15]  J. Pandolfino,et al.  Ambulatory Esophageal pH Monitoring Using a Wireless System , 2003, American Journal of Gastroenterology.

[16]  Ieee Standards Board IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields, 3kHz to 300 GHz , 1992 .

[17]  Wolfgang Fichtner,et al.  Signal Transmission by Galvanic Coupling Through the Human Body , 2010, IEEE Transactions on Instrumentation and Measurement.

[19]  A. Ivorra,et al.  Demonstration of 2 mm Thick Microcontrolled Injectable Stimulators Based on Rectification of High Frequency Current Bursts , 2017, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[20]  Wolfgang Fichtner,et al.  Galvanic Coupling Enabling Wireless Implant Communications , 2009, IEEE Transactions on Instrumentation and Measurement.

[21]  Jarno Riistama,et al.  Electrochemical noise properties of different electrode materials in different electrolytes , 2007, BSN.

[22]  A. Keys,et al.  Density and composition of mammalian muscle , 1960 .

[23]  Li Wang,et al.  Fundamentals of intrathoracic impedance monitoring in heart failure. , 2007, The American journal of cardiology.

[24]  R. D. Black,et al.  Recent Advances in Translational Work on Implantable Sensors , 2011, IEEE Sensors Journal.

[25]  Antoni Ivorra,et al.  In Vivo Demonstration of Addressable Microstimulators Powered by Rectification of Epidermically Applied Currents for Miniaturized Neuroprostheses , 2015, PloS one.

[26]  S. Cogan Neural stimulation and recording electrodes. , 2008, Annual review of biomedical engineering.

[27]  C. Grimbergen,et al.  Investigation into the origin of the noise of surface electrodes , 2002, Medical and Biological Engineering and Computing.

[28]  C. Lau,et al.  Intrathoracic Impedance Monitoring in Patients With Heart Failure: Correlation With Fluid Status and Feasibility of Early Warning Preceding Hospitalization , 2005, Circulation.

[29]  J. Patrick Reilly,et al.  Applied Bioelectricity: From Electrical Stimulation to Electropathology , 1998 .

[30]  Kristen L Helton,et al.  The First-in-Man "Si Se Puede" Study for the use of micro-oxygen sensors (MOXYs) to determine dynamic relative oxygen indices in the feet of patients with limb-threatening ischemia during endovascular therapy. , 2015, Journal of vascular surgery.

[31]  Antoni Ivorra,et al.  Power Transfer by Volume Conduction: In Vitro Validated Analytical Models Predict DC Powers Above 1 mW in Injectable Implants , 2020, IEEE Access.

[32]  Nitish V. Thakor,et al.  Wireless Power Transfer Strategies for Implantable Bioelectronics , 2017, IEEE Reviews in Biomedical Engineering.

[33]  D. Farina,et al.  Long-term implant of intramuscular sensors and nerve transfers for wireless control of robotic arms in above-elbow amputees , 2019, Science Robotics.

[34]  Electromagnetic pulse distortion in living tissue , 1996, Medical and Biological Engineering and Computing.

[35]  Antoni Ivorra,et al.  In vivo demonstration of injectable microstimulators based on charge-balanced rectification of epidermically applied currents , 2015, Journal of neural engineering.

[36]  William T. Abraham,et al.  Impact of Practice-Based Management of Pulmonary Artery Pressures in 2000 Patients Implanted With the CardioMEMS Sensor , 2017, Circulation.