Fast methods for approximation of resolution and covariance for SPECT

Resolution and covariance predictors have been derived previously for penalized-likelihood estimators. These predictors can provide accurate approximations to the local resolution properties and covariance functions for tomographic systems given a good estimate of the mean measurements. However, when numerous evaluations are made repeatedly (as in penalty design or calculation of variance images), these predictors still require large amounts of computing time. In, we discussed methods for precomputing a large portion of the predictor for shift-invariant system geometries. In this paper, we generalize the efficient procedure discussed in to shift-variant single photon emission computed tomography (SPECT) systems. This generalization relies on a new attenuation approximation and several observations on the symmetries in SPECT systems. These new general procedures apply to both 2D and fully-3D SPECT models, that may be either precomputed and stored, or written in procedural form.

[1]  Jeffrey A. Fessler Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): applications to tomography , 1996, IEEE Trans. Image Process..

[2]  Richard M. Leahy,et al.  Resolution and noise properties of MAP reconstruction for fully 3-D PET , 2000, IEEE Transactions on Medical Imaging.

[3]  Richard M. Leahy,et al.  A theoretical study of the contrast recovery and variance of MAP reconstructions with applications to the selection of smoothing parameters , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[4]  Jeffrey A. Fessler,et al.  Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction , 2000, IEEE Transactions on Medical Imaging.

[5]  Jeffrey A. Fessler,et al.  Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems , 2004, IEEE Transactions on Medical Imaging.

[6]  Jeffrey A. Fessler,et al.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs , 1996, IEEE Trans. Image Process..

[7]  Richard M. Leahy,et al.  A theoretical study of the contrast recovery and variance of MAP reconstructions from PET data , 1999, IEEE Transactions on Medical Imaging.

[8]  Richard M. Leahy,et al.  Covariance approximation for fast and accurate computation of channelized Hotelling observer statistics , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[9]  Yuxiang Xing,et al.  Efficient calculation of resolution and variance in 2-D circular-orbit SPECT , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).