A non-contact vital sign monitoring system for ambulances using dual-frequency microwave radars

We developed a novel non-contact monitoring system to measure the vital signs of casualties inside a moving ambulance. This system was designed to prevent exposure of patients to infectious organisms under biochemical hazard conditions. The system consists of two microwave radars: a 10-GHz respiratory-monitoring radar is positioned 20 cm away from the surface of the isolator. The 24-GHz cardiac-monitoring radar is positioned below the stretcher underneath the isolator. The subject (22.13 ± 0.99 years) was placed inside the isolator on a stretcher in the simulated ambulance. While the ambulance was in motion at a speed of approximately 10 km/h, the heart rates determined by the cardiac-monitoring radar correlated significantly with those measured by ECG (r = 0.69, p < 0.01), and the respiratory rates derived from the respiratory-monitoring radar correlated with those measured by the respiration curves (r = 0.97, p < 0.0001). The proposed system appears promising for future on-ambulance monitoring of the vital sign of casualties exposed to toxins.

[1]  J.L. Jacobs,et al.  Characterization of a novel heart and respiratory rate sensor , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  G. Drzewiecki,et al.  Measurement and monitoring of electrocardiogram belt tension in premature infants for assessment of respiratory function , 2007, Biomedical engineering online.

[3]  T. Matsui,et al.  Biomedical engineering's contribution to defending the homeland , 2004, IEEE Engineering in Medicine and Biology Magazine.

[4]  Masayuki Ishihara,et al.  A novel autonomic activation measurement method for stress monitoring: non-contact measurement of heart rate variability using a compact microwave radar , 2008, Medical & Biological Engineering & Computing.

[5]  Kun-mu Chen,et al.  An X-Band Microwave Life-Detection System , 1986, IEEE Transactions on Biomedical Engineering.

[6]  Siegfried Piepenbrock,et al.  In vivo myograph measurement of muscle contraction at optimal length , 2007, Biomedical engineering online.

[7]  B. Takase,et al.  Non-contact determination of vital sign alterations in hypovolaemic states induced by massive haemorrhage: An experimental attempt to monitor the condition of injured persons behind barriers or under disaster rubble , 2004, Medical and Biological Engineering and Computing.

[8]  K. Hoya,et al.  Acute Systemic Inflammatory Response Syndrome in Subarachnoid Hemorrhage , 2001, Stroke.

[9]  Masayuki Ishihara,et al.  A novel method to prevent secondary exposure of medical and rescue personnel to toxic materials under biochemical hazard conditions using microwave radar and infrared thermography , 2004, IEEE Transactions on Biomedical Engineering.

[10]  Yong Huang,et al.  Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier , 2000, IEEE Transactions on Biomedical Engineering.

[11]  Huey-Ru Chuang,et al.  Automatic clutter-canceler for microwave life-detection systems , 1991 .

[12]  Masayuki Ishihara,et al.  Non-contact respiratory monitoring system using a ceiling-attached microwave antenna , 2006, Medical and Biological Engineering and Computing.

[13]  Mami Tanaka,et al.  Development of a wearable mental stress evaluation system using PVDF film sensor , 2006 .