Systemic vascular resistance index determined by thoracic electrical bioimpedance predicts the risk for maternal hypotension during regional anesthesia for cesarean delivery.

OBJECTIVE Our purpose was to evaluate the predictive value of the baseline systemic vascular resistance index for the development of maternal hypotension during regional anesthesia for cesarean delivery. STUDY DESIGN Patients receiving a standardized spinal or epidural anesthetic for nonemergency cesarean delivery were studied prospectively. Hemodynamic data were obtained noninvasively with an NCCOM-3 cardiac output monitor (Bomed Medical Manufacturing, Irvine, Calif.), which uses thoracic electrical bioimpedance to estimate stroke volume and cardiac output. Measurements obtained were indexed to body surface area. The systemic vascular resistance index was calculated from mean arterial pressure and thoracic electrical bioimpedance-derived cardiac index. Hemodynamic data obtained were analyzed to identify statistically significant predictors of maternal hypotension. RESULTS Maternal hypotension occurred in 24 of 42 (57%) patients studied. The incidence of hypotension did not differ between the types of anesthesia: spinal 17 of 274 (62%) versus epidural 7 of 15 (47%, p=0.48). The mean interval to the onset of hypotension was 12.2 minutes (SD 2.2 minutes, range 2 to 24 minutes). Mean (SD) baseline maternal systolic blood pressure was higher in patients who had hypotension (145 torr [4]) than those who did not (129 torr [4], p=0.01). The mean (SD) baseline systemic vascular resistance index was higher in patients who had hypotension (633 [SD 36] dyne . cm . sec-5/m2) than those who did not (454 [SD 29] dyne . cm . sec-5/m2; p =0.001). With receiver-operator characteristic curves, a baseline systemic vascular resistance index of 500 had a sensitivity of 83%, a specificity of 78%, a positive predictive value of 83%, and a negative predictive value of 78% for maternal hypotension (odds ratio 17.5, 95% confidence interval 3.1 to 109.4). A baseline systolic blood pressure of 140 torr had a sensitivity and specificity of 42% and 72%, respectively (odds ratio 1.9, 95% confidence interval 0.4 to 8.8). CONCLUSIONS Baseline systemic vascular resistance index obtained by noninvasive cardiac output monitoring with thoracic electrical bioimpedance and systolic blood pressure are useful to predict the risk for maternal hypotension with regional anesthesia. Patients with increased baseline systemic vascular resistance index or systolic blood pressure are at increased risk for hypotension.

[1]  S. Datta,et al.  Spinal anaesthesia for Caesarean section. The influence of hypotension on neonatal outcome. , 1983, Anaesthesia.

[2]  P. Arnsbo,et al.  Measurements of cardiac stroke volume in various body positions in pregnancy and during Caesarean section: a comparison between thermodilution and impedance cardiography. , 1979, Scandinavian journal of clinical and laboratory investigation.

[3]  V. Puri,et al.  RELIABILITY OF BI0IMPEDANCE CARDIAC OUTPUT DETERMINATIONS IN LOW AND HIGH FLOW STATES , 1988 .

[4]  J. Kuikka,et al.  Placental blood flow during caesarean section under lumbar extradural analgesia. , 1978, British journal of anaesthesia.

[5]  S. Shnider,et al.  Anesthesia for Obstetrics , 1993 .

[6]  J. D. Young,et al.  Comparison of thoracic electrical bioimpedance and thermodilution for the measurement of cardiac index in patients with severe sepsis. , 1993, British journal of anaesthesia.

[7]  F. Verhoeff,et al.  Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: a study of reproducibility and comparison with thermodilution. , 1991, British journal of anaesthesia.

[8]  W C Shoemaker,et al.  Multicomponent noninvasive physiologic monitoring of circulatory function. , 1988, Critical care medicine.

[9]  S. Teague,et al.  Noninvasive Evaluation of Aortic Stenosis Severity Utilizing Doppler Ultrasound and Electrical Bioimpedance , 1988, Journal of the American College of Cardiology.

[10]  R. LuccaEscobar Anesthesia for cesarean section , 1952 .

[11]  G. Molter,et al.  Determination of cardiac output during positive end-expiratory pressure--noninvasive electrical bioimpedance compared with standard thermodilution. , 1990, Critical care medicine.

[12]  E. Crosby,et al.  Epidural sufentanil does not attenuate the central haemodynamic effects of Caesarean section performed under epidural anaesthesia , 1994, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[13]  F. Spinale,et al.  Comparison of bioimpedance and thermodilution methods for determining cardiac output: experimental and clinical studies. , 1988, The Annals of thoracic surgery.

[14]  J. Pivarnik,et al.  A Comparison of Cardiac Index in Normal Term Pregnancy Using Thoracic Electrical Bio‐Impedance and Oxygen Extraction (Fick) Techniques , 1994, Obstetrics and gynecology.

[15]  D. Chestnut,et al.  The Effects of Epidural Anesthesia on Uterine Vascular Resistance, Plasma Arginine Vasopressin Concentrations, and Plasma Renin Activity During Hemorrhage in Gravid Ewes , 1994, Anesthesia and analgesia.

[16]  I. Milsom,et al.  Measurement of Cardiac Stroke Volume During Cesarean Section: A Comparison Between Impedance Cardiography and the Dye Dilution Technique , 1983 .

[17]  R. Klocke,et al.  Simultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and Doppler ultrasound. , 1994, British journal of anaesthesia.

[18]  N. Hollis,et al.  Spinal anaesthesia for Caesarean section , 1987, Anaesthesia.

[19]  R. Gotshall,et al.  Comparison of two impedance cardiographic techniques for measuring cardiac output in critically ill patients. , 1989, Critical care medicine.

[20]  J. Ouzounian,et al.  Measurement of cardiac output in pregnancy by thoracic electrical bioimpedance and thermodilution. A preliminary report. , 1989, American journal of obstetrics and gynecology.

[21]  J. Moore,et al.  Vasopressor therapy for hypotension during epidural anesthesia for cesarean section: effects on maternal and fetal flow velocity ratios. , 1992, Anesthesia and analgesia.

[22]  J. Bonica,et al.  Maternal cardiovascular dynamics. VI. Cesarean section under epidural anesthesia without epinephrine. , 1972, American journal of obstetrics and gynecology.

[23]  B. Young,et al.  Fetal lactic acidosis with epidural anesthesia. , 1982, American journal of obstetrics and gynecology.