PURPOSE
To examine the difference in distance measured by two global positioning system (GPS) units of the same model worn by the same player while performing movements common to team sports.
METHODS
Twenty elite Australian football players completed two trials of the straight line movement (10, 20, 40 m) at four speeds (walk, jog, stride, sprint), two trials of the changes of direction (COD) courses of two different frequencies (gradual and tight), and five trials of a team sport running simulation circuit. To assess inter-unit variability for total and high intensity running (HIR) distance measured in matches, data from eight field players were collected in three Australian Hockey League (AHL) matches during the 2009 season. Each subject wore two GPS devices (MinimaxX v2.5, Catapult, Australia) that collected position data at 5 Hz for each movement and match trial. The percentage difference ±90% confidence interval (CI) was used to determine differences between units.
RESULTS
Differences (±90% CI) between the units ranged from 9.9 ± 4.7% to 11.9 ± 19.5% for straight line running movements and from 9.5 ± 7.2% to 10.7 ± 7.9% in the COD courses. Similar results were exhibited in the team sport circuit (11.1 ± 4.2%). Total distance (10.3 ± 6.2%) and HIR distance (10.3 ± 15.6) measured during the match play displayed similar variability.
CONCLUSION
It is recommended that players wear the same GPS unit for each exercise session to reduce measurement error. The level of between-unit measurement error should be considered when comparing results from players wearing different GPS units.
[1]
Justin W. L. Keogh,et al.
Methodological Issues for the Application of Time‐Motion Analysis Research
,
2007
.
[2]
Aaron J. Coutts,et al.
Validity and reliability of GPS devices for measuring movement demands of team sports.
,
2010,
Journal of science and medicine in sport.
[3]
Grant Trewartha,et al.
A comparison of time-motion analysis methods for field based sports.
,
2006,
International journal of sports physiology and performance.
[4]
Stuart J. Cormack,et al.
The validity and reliability of GPS units for measuring distance in team sport specific running patterns.
,
2010,
International journal of sports physiology and performance.
[5]
Marc Portus,et al.
Validity and reliability of GPS units to monitor cricket-specific movement patterns.
,
2009,
International journal of sports physiology and performance.
[6]
John Baker,et al.
Accuracy and reliability of GPS devices for measurement of movement patterns in confined spaces for court-based sports.
,
2010,
Journal of science and medicine in sport.