Characteristics of a Blood Pump Combining the Centrifugal and Axial Pumping Principles: The Spiral Pump.

Two well-known centrifugal and axial pumping principles are used simultaneously in a new blood pump design. Inside the pump housing is a spiral impeller, a conically shaped structure with threads on the surface. The worm gears provide an axial motion of the blood column through the threads of the central cone. The rotational motion of the conical shape generates the centrifugal pumping effect and improves the efficiency of the pump without increasing hemolysis. The hydrodynamic performance of the pump was examined with a 40% glycerin-water solution at several rotation speeds. The gap between the housing and the top of the thread is a very important factor: when the gap increases, the hydrodynamic performance decreases. To determine the optimum gap, several in vitro hemolysis tests were performed with different gaps using bovine blood in a closed circuit loop under two conditions. The first simulated condition was a left ventricular assist device (LVAD) with a flow rate of 5 L/min against a pressure head of 100 mm Hg, and the second was a cardiopulmonary bypass (CPB) simulation with a flow rate of 5 L/min against 350 mm Hg of pressure. The best hemolysis results were seen at a gap of 1.5 mm with the normalized index of hemolysis (NIH) of 0.0063 ± 0.0020 g/100 L and 0.0251 ± 0.0124 g/100 L (mean ± SD; n = 4) for LVAD and CPB conditions, respectively.

[1]  G Damm,et al.  Baylor Gyro Pump: a completely seal-less centrifugal pump aiming for long-term circulatory support. , 2008, Artificial organs.

[2]  Y Nosé,et al.  In vitro performance of the Baylor/NASA axial flow pump. , 2008, Artificial organs.

[3]  H. Nishida,et al.  Development of the Terumo Capiox centrifugal pump and its clinical application to open heart surgery: a comparative study with the roller pump. , 2008, Artificial organs.

[4]  H. Oshiyama,et al.  A straight path centrifugal blood pump concept in the Capiox centrifugal pump. , 2008, Artificial organs.

[5]  Y Nosé,et al.  A fluid dynamic analysis of a rotary blood pump for design improvement. , 2008, Artificial organs.

[6]  H. Thoma,et al.  In vitro investigation of thrombogenesis in rotary blood pumps. , 2008, Artificial organs.

[7]  R K Jarvik,et al.  System considerations favoring rotary artificial hearts with blood-immersed bearings. , 1995, Artificial organs.

[8]  Y Nosé,et al.  Development and evaluation of antithrombogenic centrifugal pump: the Baylor C-Gyro Pump Eccentric Inlet Port Model. , 1994, Artificial organs.

[9]  Y Nosé,et al.  The next generation Baylor C-Gyro Pump: antithrombogenic "free impeller" design for long-term centrifugal VAD. , 1994, Artificial organs.

[10]  E. Leonard,et al.  The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. Guidelines for choosing a blood pump. , 1993, The Journal of thoracic and cardiovascular surgery.

[11]  U Losert,et al.  Minimization of Hemolysis in Centrifugal Blood Pumps: Influence of Different Geometries , 1993, The International journal of artificial organs.

[12]  J. Piehler,et al.  Bio-medicus ventricular assist device for salvage of cardiac surgical patients. , 1991, The Annals of thoracic surgery.

[13]  L. Joyce,et al.  Experience with the Sarns centrifugal pump as a ventricular assist device. , 1990, ASAIO transactions.

[14]  H. Harasaki,et al.  Hemolysis. A comparative study of four nonpulsatile pumps. , 1988, ASAIO transactions.

[15]  Y. Nosé Blood clotting problems in the artificial heart devices. , 1967, Journal of biomedical materials research.

[16]  Y Nosé,et al.  Internal hydraulic loss in a seal-less centrifugal Gyro pump. , 1994, Artificial organs.

[17]  Y Nosé,et al.  Axial flow ventricular assist device: system performance considerations. , 1994, Artificial organs.

[18]  Y Nosé,et al.  Cardiopulmonary bypass with Nikkiso and BioMedicus centrifugal pumps. , 1994, Artificial organs.

[19]  Y Nosé,et al.  The need for standardizing the index of hemolysis. , 1994, Artificial organs.

[20]  G Damm,et al.  Successful thermal management of a totally implantable ventricular assist system. , 1994, Artificial organs.

[21]  G Damm,et al.  An ultimate, compact, seal-less centrifugal ventricular assist device: Baylor C-Gyro pump. , 1994, Artificial organs.

[22]  Y Nosé,et al.  Development of the Baylor/NASA axial flow ventricular assist device: in vitro performance and systematic hemolysis test results. , 1994, Artificial organs.

[23]  B. Griffith,et al.  How much do we need to know before approving a ventricular assist device? , 1993, The Annals of thoracic surgery.

[24]  M E DeBakey,et al.  Left ventricular bypass pump for cardiac assistance. Clinical experience. , 1971, The American journal of cardiology.