Development of a fluorescent microsphere technique for rapid histological determination of cerebral blood flow

The purpose of this study was to develop a more efficient fluorescent microsphere method to facilitate the rapid use of the histological technique and to enable its use in large tissue regions. Using fluorescent plate/slide imaging technology and automated detection and analysis software, we were able to rapidly image, detect, and count 3 separate microsphere colors in 200 microm thick tissue sections from piglet brain. In resting newborn piglets (n=6) on isoflurane anesthesia, we measured a median total cerebral blood flow (CBF) of 105 ml/min/100g (range 27-206 ml/min/100 g). Compared with other FM analysis methods, our method reduces the time required to determine blood flow, improves accuracy in lipid-rich tissues and large tissue regions and, unlike the radiolabeled microsphere method, can be combined with histological analysis.

[1]  J I Hoffman,et al.  Some sources of error in measuring regional blood flow with radioactive microspheres. , 1971, Journal of applied physiology.

[2]  D. Grier,et al.  Methods of Digital Video Microscopy for Colloidal Studies , 1996 .

[3]  U. Zwiener,et al.  Validation of the multiple colored microsphere technique for regional blood flow measurements in newborn piglets , 1997, Basic Research in Cardiology.

[4]  R. S. Reneman,et al.  Development of a novel fluorescent microsphere technique to combine serial cerebral blood flow measurements with histology in the rat , 2003, Journal of Neuroscience Methods.

[5]  J I Hoffman,et al.  Blood flow measurements with radionuclide-labeled particles. , 1977, Progress in cardiovascular diseases.

[6]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[7]  R W Glenny,et al.  Histological methods to determine blood flow distribution with fluorescent microspheres. , 1998, Biotechnic & histochemistry : official publication of the Biological Stain Commission.

[8]  R. Glenny,et al.  Cerebral blood flow determinations using fluorescent microspheres: variations on the sedimentation method validated , 1999, Journal of Neuroscience Methods.

[9]  N. M. Buckley,et al.  Maturation of circulatory system in three mammalian models of human development. , 1986, Comparative biochemistry and physiology. A, Comparative physiology.

[10]  W. Armstead,et al.  Effects of ischemia on brain blood flow and oxygen consumption of newborn pigs. , 1989, The American journal of physiology.

[11]  R W Glenny,et al.  Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion. , 1993, Journal of applied physiology.

[12]  F W Prinzen,et al.  Developments in non-radioactive microsphere techniques for blood flow measurement. , 1994, Cardiovascular research.

[13]  W Flameng,et al.  Fluorescent microsphere technique to measure cerebral blood flow in the rat , 2006, Nature Protocols.

[14]  R. Traystman,et al.  Nitric Oxide and Prostanoids Contribute to Isoflurane‐induced Cerebral Hyperemia in Pigs , 1994, Anesthesiology.