Experimental study of the saturation and the cross-magnetizing phenomenon in saturated synchronous machines

The cross-magnetizing effect in both the d- and q-axis in a small salient-pole machine was measured. Two simple equations describing the cross-magnetizing effect in both axis directions are derived. An accurate saturation representation that includes the effect of both the machine-saturated reactances and the cross-magnetizing phenomena is also given. In addition to this, the modified phasor diagram and power/load angle relationship are obtained. The results of the machine output power obtained by this technique show a good agreement with those obtained from test. The saturation effect in changing the power/load angle curves is seen to be noticeably large and depends mainly upon the cross-magnetizing effect. >

[1]  K. E. Hallenius On the theory of main flux saturation in smooth airgap electrical machines , 1986 .

[2]  M. El-sherbiny,et al.  Analysis of Dynamic Performance of Saturated Machine and Analog Simulation , 1982, IEEE Transactions on Power Apparatus and Systems.

[3]  E. F. Fuchs,et al.  Lastabhängige transiente Reaktanzen von gesättigten Turbogeneratoren , 1973 .

[4]  R. G. Harley,et al.  Comparative study of saturation methods in synchronous machine models , 1980 .

[5]  T. H. Barton,et al.  Small Perturbation Linearization of the Saturated Synchronous Machine Equations , 1972 .

[6]  Ewald F. Fuchs,et al.  Nonlinear Theory of Turboalternators Part II. Load Dependent Synchronous Reactances , 1973 .

[7]  R. Dunlop,et al.  Verification of Synchronous Machine Modeling in Stability Studies: Comparative Tests of Digital and Physical Scale Model Power System Simulations , 1979, IEEE Transactions on Power Apparatus and Systems.

[8]  A.B.J. Reece,et al.  Turbine-generator steady-state reactances , 1985 .

[9]  N.A. Demerdash,et al.  A simplified approach to determination of saturated synchronous reactances of large turbogenerators under load , 1976, IEEE Transactions on Power Apparatus and Systems.

[10]  J. E. Brown,et al.  Cross-Saturation in Smooth-Air-Gap Electrical Machines , 1986, IEEE Power Engineering Review.

[11]  M.B.A. Kamoun,et al.  Experimental study of the effect of saturation on the steady state operation of a salient pole microalternator , 1985 .

[12]  K. P. Kovacs On the Theory of Cylindrical Rotor AC Machines, Including Main Flux Saturation , 1984, IEEE Power Engineering Review.

[13]  Philip Solomon,et al.  Discussion of the Paper , 1961 .