Choice of in vivo versus idealized velocity boundary conditions influences physiologically relevant flow patterns in a subject-specific simulation of flow in the human carotid bifurcation.

Accurate fluid mechanics models are important tools for predicting the flow field in the carotid artery bifurcation and for understanding the relationship between hemodynamics and the initiation and progression of atherosclerosis. Clinical imaging modalities can be used to obtain geometry and blood flow data for developing subject-specific human carotid artery bifurcation models. We developed subject-specific computational fluid dynamics models of the human carotid bifurcation from magnetic resonance (MR) geometry data and phase contrast MR velocity data measured in vivo. Two simulations were conducted with identical geometry, flow rates, and fluid parameters: (1) Simulation 1 used in vivo measured velocity distributions as time-varying boundary conditions and (2) Simulation 2 used idealized fully-developed velocity profiles as boundary conditions. The position and extent of negative axial velocity regions (NAVRs) vary between the two simulations at any given point in time, and these regions vary temporally within each simulation. The combination of inlet velocity boundary conditions, geometry, and flow waveforms influences NAVRs. In particular, the combination of flow division and the location of the velocity peak with respect to individual carotid geometry landmarks (bifurcation apex position and the departure angle of the internal carotid) influences the size and location of these reversed flow zones. Average axial wall shear stress (WSS) distributions are qualitatively similar for the two simulations; however, instantaneous WSS values vary with the choice of velocity boundary conditions. By developing subject-specific simulations from in vivo measured geometry and flow data and varying the velocity boundary conditions in otherwise identical models, we isolated the effects of measured versus idealized velocity distributions on blood flow patterns. Choice of velocity distributions at boundary conditions is shown to influence pathophysiologically relevant flow patterns in the human carotid bifurcation. Although mean WSS distributions are qualitatively similar for measured and idealized inlet boundary conditions, instantaneous NAVRs differ and warrant imposing in vivo velocity boundary conditions in computational simulations. A simulation based on in vivo measured velocity distributions is preferred for modeling hemodynamics in subject-specific carotid artery bifurcation models when studying atherosclerosis initiation and development.

[1]  J. Womersley Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known , 1955, The Journal of physiology.

[2]  J. Womersley,et al.  Velocity profiles of oscillating arterial flow, with some calculations of viscous drag and the Reynolds number , 1955, The Journal of physiology.

[3]  K. Balasubramanian An experimental investigation of steady flow at an arterial bifurcation , 1979 .

[4]  D. Giddens,et al.  Steady flow in a model of the human carotid bifurcation. Part II--laser-Doppler anemometer measurements. , 1982, Journal of biomechanics.

[5]  D. Giddens,et al.  Steady flow in a model of the human carotid bifurcation. Part I--flow visualization. , 1982, Journal of biomechanics.

[6]  Hemodynamics and atherogenesis at the human carotid bifurcation , 1983 .

[7]  T. O'donnell,et al.  Pulsatile flow and atherosclerosis in the human carotid bifurcation: Positive correlation between plaque location and low and oscillating shear stress: Ku DN, Giddens DP, Zarins CK, et al. Arteriosclerosis 1985; 5: 293–302 , 1986 .

[8]  C L Dumoulin,et al.  Secondary flow in the human common carotid artery imaged by MR angiography. , 1992, Journal of biomechanical engineering.

[9]  S Glagov,et al.  Shear stress at a compliant model of the human carotid bifurcation. , 1994, Journal of biomechanical engineering.

[10]  P. Olver,et al.  Conformal curvature flows: From phase transitions to active vision , 1996, ICCV 1995.

[11]  K. Perktold,et al.  Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model. , 1995, Journal of biomechanics.

[12]  D A Steinman,et al.  Computational blood flow modelling: errors associated with reconstructing finite element models from magnetic resonance images. , 1997, Journal of biomechanics.

[13]  B. Rutt,et al.  Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects. , 1998, Journal of vascular surgery.

[14]  A D Hughes,et al.  Blood flow and vessel mechanics in a physiologically realistic model of a human carotid arterial bifurcation. , 2000, Journal of biomechanics.

[15]  Q. Long,et al.  Numerical study of blood flow in an anatomically realistic aorto‐iliac bifurcation generated from MRI data , 2000, Magnetic resonance in medicine.

[16]  A. Hughes,et al.  Influence of head position on carotid hemodynamics in young adults. , 2004, American journal of physiology. Heart and circulatory physiology.

[17]  David A. Steinman,et al.  Image-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries , 2002, Annals of Biomedical Engineering.

[18]  C. R. Ethier,et al.  Accuracy of Computational Hemodynamics in Complex Arterial Geometries Reconstructed from Magnetic Resonance Imaging , 2004, Annals of Biomedical Engineering.

[19]  B. Rutt,et al.  Reproducibility of Image-Based Computational Fluid Dynamics Models of the Human Carotid Bifurcation , 2003, Annals of Biomedical Engineering.

[20]  D. Ku,et al.  Effect of a lipid pool on stress/strain distributions in stenotic arteries: 3-D fluid-structure interactions (FSI) models. , 2004, Journal of biomechanical engineering.

[21]  James Robert Costello,et al.  Effect of Material Properties and Hemodynamics on the Healing of Vascular Grafts in baboons , 2004 .

[22]  David A. Steinman,et al.  Variation in the Carotid Bifurcation Geometry of Young Versus Older Adults: Implications for Geometric Risk of Atherosclerosis , 2005, Stroke.

[23]  L. Antiga,et al.  Inlet conditions for image-based CFD models of the carotid bifurcation: is it reasonable to assume fully developed flow? , 2006, Journal of biomechanical engineering.