Thermodynamic and economic analysis for ground-source heat pump system coupled with borehole free cooling

Abstract The energy performance of a ground-source heat pump (GSHP) system will gradually deteriorate and the annual operation cost will increase annually if the heat injected into and extracted from the underground soil is imbalanced. To solve the underground heat balance problem and improve the energy efficiency of the system in the long-term, a temperature difference control strategy for the GSHP system coupled with borehole free cooling (BFC) is proposed in this study. An office building located in Tianjin is selected as a case study. According to the established simulation models by Designbuilder and TRNSYS, measured data is used for validation. The new control strategy and two other contrasting control strategies are validated with TRNSYS. The results show that free cooling with borehole water matches the indoor air parameter with the design indoor conditions and also improves the average annual cooling efficiency of the GSHP system to 16.22. Moreover, the underground soil heat imbalance can be improved, and the average annual energy consumption and operation cost can be decreased to 55.9% and 56.0%, respectively. The proposed control strategy has the potential to improve heat imbalance and reduce energy consumption and operation cost for GSHP systems.

[1]  Ryozo Ooka,et al.  Optimization method for multiple heat source operation including ground source heat pump considering dynamic variation in ground temperature , 2017 .

[2]  Yan Gao,et al.  Thermal performance and operation strategy optimization for a practical hybrid ground-source heat-pump system , 2014 .

[3]  Wenzhi Cui,et al.  Optimization of design and operation parameters for hybrid ground-source heat pump assisted with cooling tower , 2015 .

[4]  Mohammad. Rasul,et al.  Thermal-comfort analysis and simulation for various low-energy cooling-technologies applied to an office building in a subtropical climate , 2008 .

[5]  Pingfang Hu,et al.  Study on intermittent operation strategies of a hybrid ground-source heat pump system with double-cooling towers for hotel buildings , 2014 .

[6]  Philipp Blum,et al.  Greenhouse gas emission savings of ground source heat pump systems in Europe: A review , 2012 .

[7]  Josua P. Meyer,et al.  A performance comparison between an air‐source and a ground‐source reversible heat pump , 2001 .

[8]  Yang Hongxing,et al.  Experimental studies on a ground coupled heat pump with solar thermal collectors for space heating , 2011 .

[9]  Michele De Carli,et al.  Long-term analysis of two GSHP systems using validated numerical models and proposals to optimize the operating parameters , 2015 .

[10]  Seth B. Dworkin,et al.  Characterizing the Effect of an Off-Peak Ground Pre-1 Cool Control Strategy 2 on Hybrid Ground Source Heat Pump Systems , 2017 .

[11]  Xianting Li,et al.  A new ground-coupled heat pump system integrated with a multi-mode air-source heat compensator to eliminate thermal imbalance in cold regions , 2015 .

[12]  Igor Mujan,et al.  Experimental validation of a EnergyPlus model: Application of a multi-storey naturally ventilated double skin façade , 2016 .

[13]  Alan S. Fung,et al.  Heating and cooling performance characterisation of ground source heat pump system by testing and TRNSYS simulation , 2015 .

[14]  Ryozo Ooka,et al.  Theoretical analysis on ground source heat pump and air source heat pump systems by the concepts of cool and warm exergy , 2014 .

[15]  Tony Roskilly,et al.  This Work Is Licensed under a Creative Commons Attribution 4.0 International License Royapoor M, Roskilly T. Building Model Calibration Using Energy and Environmental Data. Energy and Buildings Building Model Calibration Using Energy and Environmental Data Keywords: Model Calibration Measured Energy , 2022 .

[16]  Andrea Costa,et al.  Model calibration for building energy efficiency simulation , 2014 .

[17]  Anthony Paul Roskilly,et al.  Office building cooling load reduction using thermal analysis method – A case study , 2017 .

[18]  Erik Dotzauer,et al.  Simple model for prediction of loads in district-heating systems , 2002 .

[19]  W. Magnus On the exponential solution of differential equations for a linear operator , 1954 .

[20]  Belinda Pelaz,et al.  Energy assessment and optimization of perforated metal sheet double skin façades through Design Builder; A case study in Spain , 2016 .

[21]  Ferri P. Hassani,et al.  Analysis of the effect of global climate change on ground source heat pump systems in different climate categories , 2015 .

[22]  Aie World Energy Outlook 2011 , 2001 .

[23]  Wenxing Shi,et al.  Combining ground source absorption heat pump with ground source electrical heat pump for thermal balance, higher efficiency and better economy in cold regions , 2015 .

[24]  Jeffrey D. Spitler,et al.  Status and development of hybrid energy systems from hybrid ground source heat pump in China and other countries , 2014 .

[25]  Robert J. Moffat,et al.  Describing the Uncertainties in Experimental Results , 1988 .

[26]  Jacob H. Stang,et al.  Load prediction method for heat and electricity demand in buildings for the purpose of planning for mixed energy distribution systems , 2008 .

[27]  Karoly Nagy,et al.  Use of renewable energy sources in light of the “New Energy Strategy for Europe 2011–2020” , 2012 .

[28]  Long Liu,et al.  Performance evaluation before and after solar seasonal storage coupled with ground source heat pump , 2015 .

[29]  Cheng Qian,et al.  Investigation on the feasibility and performance of ground source heat pump (GSHP) in three cities in cold climate zone, China , 2015 .

[30]  M. Fasiuddin,et al.  HVAC system strategies for energy conservation in commercial buildings in Saudi Arabia , 2011 .

[31]  Shengwei Wang,et al.  Performance analysis of hybrid ground source heat pump systems based on ANN predictive control , 2014 .

[32]  Tao Yang,et al.  Experimental study of a solar-assisted ground-coupled heat pump system with solar seasonal thermal storage in severe cold areas , 2010 .

[33]  Kwang Ho Lee,et al.  Study on the Performance of a Ground Source Heat Pump System Assisted by Solar Thermal Storage , 2015 .

[34]  R. Al-Khoury,et al.  A spectral model for transient heat flow in a double U-tube geothermal heat pump system , 2016 .

[35]  Wei Xu,et al.  Feasibility and performance study of the hybrid ground-source heat pump system for one office building in Chinese heating dominated areas , 2017 .

[36]  Wenxing Shi,et al.  A potential solution for thermal imbalance of ground source heat pump systems in cold regions: Ground source absorption heat pump , 2013 .