Robust Short-Lag Spatial Coherence Imaging

Short-lag spatial coherence (SLSC) imaging displays the spatial coherence between backscattered ultrasound echoes instead of their signal amplitudes and is more robust to noise and clutter artifacts when compared with traditional delay-and-sum (DAS) B-mode imaging. However, SLSC imaging does not consider the content of images formed with different lags, and thus does not exploit the differences in tissue texture at each short-lag value. Our proposed method improves SLSC imaging by weighting the addition of lag values (i.e., M-weighting) and by applying robust principal component analysis (RPCA) to search for a low-dimensional subspace for projecting coherence images created with different lag values. The RPCA-based projections are considered to be denoised versions of the originals that are then weighted and added across lags to yield a final robust SLSC (R-SLSC) image. Our approach was tested on simulation, phantom, and in vivo liver data. Relative to DAS B-mode images, the mean contrast, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) improvements with R-SLSC images are 21.22 dB, 2.54, and 2.36, respectively, when averaged over simulated, phantom, and in vivo data and over all lags considered, which corresponds to mean improvements of 96.4%, 121.2%, and 120.5%, respectively. When compared with SLSC images, the corresponding mean improvements with R-SLSC images were 7.38 dB, 1.52, and 1.30, respectively (i.e., mean improvements of 14.5%, 50.5%, and 43.2%, respectively). Results show great promise for smoothing out the tissue texture of SLSC images and enhancing anechoic or hypoechoic target visibility at higher lag values, which could be useful in clinical tasks such as breast cyst visualization, liver vessel tracking, and obese patient imaging.

[1]  D H Evans,et al.  On-line classification of arterial stenosis severity using principal component analysis applied to Doppler ultrasound signals. , 1982, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[2]  Gregg E Trahey,et al.  Equivalence of time and aperture domain additive noise in ultrasound coherence. , 2015, The Journal of the Acoustical Society of America.

[3]  F. Zernike The concept of degree of coherence and its application to optical problems , 1938 .

[4]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  Michael C. Kolios,et al.  Improving the quality of photoacoustic images using the short-lag spatial coherence imaging technique , 2013, Photonics West - Biomedical Optics.

[6]  Dongwoon Hyun,et al.  Real-time high-framerate in vivo cardiac SLSC imaging with a GPU-based beamformer , 2015, 2015 IEEE International Ultrasonics Symposium (IUS).

[7]  G. Sapiro,et al.  A collaborative framework for 3D alignment and classification of heterogeneous subvolumes in cryo-electron tomography. , 2013, Journal of structural biology.

[8]  Arvind Ganesh,et al.  Fast Convex Optimization Algorithms for Exact Recovery of a Corrupted Low-Rank Matrix , 2009 .

[9]  Jeffrey C. Bamber,et al.  Spatial Coherence and Beamformer Gain , 2002 .

[10]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[11]  J. Ophir,et al.  IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[12]  Gregg E Trahey,et al.  In vivo application of short-lag spatial coherence imaging in human liver. , 2013, Ultrasound in medicine & biology.

[13]  Gianmarco Pinton,et al.  Spatial coherence in human tissue: implications for imaging and measurement , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[14]  Emad M Boctor,et al.  Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds. , 2013, Biomedical optics express.

[15]  Christopher M. Bishop,et al.  Pattern Recognition and Machine Learning (Information Science and Statistics) , 2006 .

[16]  Yi Ma,et al.  The Augmented Lagrange Multiplier Method for Exact Recovery of Corrupted Low-Rank Matrices , 2010, Journal of structural biology.

[17]  Muyinatu A. Lediju Bell,et al.  Improved contrast in laser-diode-based photoacoustic images with short-lag spatial coherence beamforming , 2014, 2014 IEEE International Ultrasonics Symposium.

[18]  M. Turk,et al.  Eigenfaces for Recognition , 1991, Journal of Cognitive Neuroscience.

[19]  John Wright,et al.  Robust Principal Component Analysis: Exact Recovery of Corrupted Low-Rank Matrices via Convex Optimization , 2009, NIPS.

[20]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[21]  Raoul Mallart,et al.  The van Cittert–Zernike theorem in pulse echo measurements , 1991 .

[22]  G. E. Trahey,et al.  Short-lag spatial coherence of backscattered echoes: imaging characteristics , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  Caterina M Gallippi,et al.  Robust principal component analysis and clustering methods for automated classification of tissue response to ARFI excitation. , 2008, Ultrasound in medicine & biology.

[24]  Jiawei Han,et al.  Data Mining: Concepts and Techniques , 2000 .

[25]  R. Waag,et al.  About the application of the van Cittert-Zernike theorem in ultrasonic imaging , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  S.W. Smith,et al.  Speckle Pattern Correlation with Lateral Aperture Translation: Experimental Results and Implications for Spatial Compounding , 1986, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[27]  G. Trahey,et al.  Short-lag spatial coherence imaging of cardiac ultrasound data: initial clinical results. , 2013, Ultrasound in medicine & biology.

[28]  O Somphone,et al.  The 2014 liver ultrasound tracking benchmark , 2015, Physics in medicine and biology.

[29]  Dongwoon Hyun,et al.  Short-lag spatial coherence imaging on matrix arrays, Part 1: Beamforming methods and simulation studies , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[30]  O. Bernard,et al.  Plane-Wave Imaging Challenge in Medical Ultrasound , 2016, 2016 IEEE International Ultrasonics Symposium (IUS).

[31]  T P O'Neill,et al.  Breast ultrasound. , 1998, The Surgical clinics of North America.

[32]  Erwin J. Alles,et al.  Photoacoustic clutter reduction using short-lag spatial coherence weighted imaging , 2014, 2014 IEEE International Ultrasonics Symposium.

[33]  I. Jolliffe Principal Component Analysis and Factor Analysis , 1986 .

[34]  Lediju Bell,et al.  Improved Endocardial Border Definition with Short-Lag Spatial Coherence (SLSC) Imaging , 2012 .

[35]  John Wright,et al.  Robust Principal Component Analysis: Exact Recovery of Corrupted Low-Rank Matrices via Convex Optimization , 2009, NIPS.

[36]  Dongwoon Hyun,et al.  A GPU-based real-time spatial coherence imaging system , 2013, Medical Imaging.

[37]  J. Walkup,et al.  Statistical optics , 1986, IEEE Journal of Quantum Electronics.

[38]  G.E. Trahey,et al.  A motion-based approach to abdominal clutter reduction , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[39]  W F Walker,et al.  Complex principal components for robust motion estimation , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[40]  R. Entrekin,et al.  Real Time Spatial Compound Imaging in breast ultrasound: Technology and early clinical experience , 2000 .

[41]  P. H. Cittert,et al.  Die Wahrscheinliche Schwingungsverteilung in Einer von Einer Lichtquelle Direkt Oder Mittels Einer Linse Beleuchteten Ebene , 1934 .

[42]  Dongwoon Hyun,et al.  Lesion Detectability in Diagnostic Ultrasound with Short-Lag Spatial Coherence Imaging , 2011, Ultrasonic imaging.

[43]  Gregg Trahey,et al.  In vivo performance evaluation of short-lag spatial coherence and harmonic spatial coherence imaging in fetal ultrasound , 2013, 2013 IEEE International Ultrasonics Symposium (IUS).

[44]  Dongwoon Hyun,et al.  Short-lag spatial coherence imaging on matrix arrays, Part II: Phantom and in vivo experiments , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[45]  B. Moore Principal component analysis in linear systems: Controllability, observability, and model reduction , 1981 .

[46]  Muyinatu A. Lediju Bell,et al.  Resolution and brightness characteristics of short-lag spatial coherence (SLSC) images , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[47]  Muyinatu A. Lediju Bell,et al.  Photoacoustic-based approach to surgical guidance performed with and without a da Vinci robot , 2017, Journal of Biomedical Optics.