Computer-Aided Customized Shape Design of an N95 Filtering Facepiece Respirator

A respirator protects its user by sealing the user’s face and filtering hazardous particles from environment. However, faceseal leakages of users-respirators always happen. First, this study investigated a computer-aided technique for designing a well fitted N95 filtering facepiece respirator (FFR) for a subject. The customized N95 FFR includes a customized contact area, a center filtering area, two straps and a nasal clip. Five base contact areas of National Institution for Occupational Safety and Health (NIOSH) headforms were created and the customized contact area was modeled using the mapping relationship between the subject and a NIOSH headform. The center filtering area was designed by considering constraints of N95 FFR shape. Second, this study used simulation-based approaches, including the FE method and computational fluid dynamics (CFD) method, to assess the performance of the customized N95 FFR on the subject. The contact pressure and the faceseal leakage from the subject-customized N95 FFR combination were compared with the results from the subjectexisting N95 FFRs combinations. The comparison showed that the customized N95 FFR provided the subject an optimized contact pressure distribution and no faceseal leakage.

[1]  Hong Liu,et al.  Rapid preliminary helmet shell design based on three-dimensional anthropometric head data , 2008 .

[2]  Yu Wang,et al.  Design automation for customized apparel products , 2005, Comput. Aided Des..

[3]  Robert B Lawrence,et al.  Comparison of five methods for fit-testing N95 filtering-facepiece respirators. , 2002, Applied occupational and environmental hygiene.

[4]  Bruce H Bitterman Application of Finite Element Modeling and Analysis to the Design of Positive Pressure Oxygen Masks , 1991 .

[5]  D L Campbell,et al.  Simulated workplace performance of N95 respirators. , 1999, American Industrial Hygiene Association journal.

[6]  Dino Piccione,et al.  Modeling the Interface Between a Respirator and the Human Face. , 1997 .

[7]  Don-Hee Han,et al.  Development of prototypes of half-mask facepieces for Koreans using the 3D digitizing design method: a pilot study. , 2004, The Annals of occupational hygiene.

[8]  Zhipeng Lei,et al.  Simulation and evaluation of respirator faceseal leaks using computational fluid dynamics and infrared imaging. , 2013, The Annals of occupational hygiene.

[9]  Charlie C. L. Wang,et al.  Flexible shape control for automatic resizing of apparel products , 2012, Comput. Aided Des..

[10]  Kl Yick,et al.  Wire frame representation of 3D moulded bra cup and its application to example-based design , 2008 .

[11]  E Newton,et al.  In vivo protective performance of N95 respirator and surgical facemask. , 2006, American journal of industrial medicine.

[12]  Ziqing Zhuang,et al.  Headform and N95 Filtering Facepiece Respirator Interaction: Contact Pressure Simulation and Validation , 2012, Journal of occupational and environmental hygiene.

[13]  Dibakar Sen,et al.  Deriving statistical fit contours and shape of an aerosol mask from 3D head scans , 2011 .

[14]  J. Russo,et al.  Computational study of breathing methods for inhalation exposure , 2011, HVAC&R Research.

[15]  Charlie C. L. Wang,et al.  Volume Parameterization for Design Automation of Customized Free-Form Products , 2007, IEEE Transactions on Automation Science and Engineering.

[16]  Bruce Bradtmiller,et al.  Head-and-Face Anthropometric Survey of U.S. Respirator Users , 2005, Journal of occupational and environmental hygiene.

[17]  Charlie C. L. Wang,et al.  Feature based 3D garment design through 2D sketches , 2003, Comput. Aided Des..

[18]  Bruce Bradtmiller,et al.  New Respirator Fit Test Panels Representing the Current U.S. Civilian Work Force , 2007, Journal of occupational and environmental hygiene.

[19]  Ziqing Zhuang,et al.  The Effect of Subject Characteristics and Respirator Features on Respirator Fit , 2005, Journal of occupational and environmental hygiene.

[20]  Stacey Benson,et al.  Digital 3-D headforms with facial features representative of the current US workforce , 2010, Ergonomics.

[21]  Charlie C. L. Wang,et al.  From Designing Products to Fabricating Them from Planar Materials , 2010, IEEE Computer Graphics and Applications.