Abstract It is well known that in many cases the responsibility for the formation of the sick-building syndrome lies with the inappropriate envelope design, the misuse of the building by the inhabitants and the combination of indoor–outdoor pollution sources. In the case of Athens Air Traffic Control Tower (ATCT), sick syndrome episodes were reported by the employees. In the present study, recently obtained indoor air quality measurements, during selected meteorological conditions, taken in the ATCT, are presented and discussed. These include concentrations of volatile organic compounds (VOCs), which in many cases were thought responsible for the poor indoor environment. The measurements cover the indoor and outdoor environment of selected building regions, the ventilation systems and the plenum under the floor. The data indicates that there are certain places in the building where the VOCs concentrations were well above outdoor levels, while in others the concentrations were lower. Further analysis of the results showed that the central ventilation system is not sufficient for the building needs and that in some areas, either due to cleaning negligence or to the construction material used, VOCs pollution sources have developed. In order to eliminate these problems and to improve the indoor environment certain actions were taken. Following these interventions a second set of measurements were collected, inside and outside the ATCT building, which indicated a substantial improvement of the indoor air quality.
[1]
Richard A. Grot,et al.
Sources and Source Strengths of Volatile Organic Compounds in a New Office Building
,
1991
.
[2]
Shuncheng Lee,et al.
Investigation of indoor air quality at residential homes in Hong Kong - Case study
,
2002
.
[3]
Rufus Edwards,et al.
VOC concentrations measured in personal samples and residential indoor, outdoor and workplace microenvironments in EXPOLIS-Helsinki, Finland
,
2001
.
[4]
Povl Ole Fanger,et al.
European audit project to optimise indoor air quality and energy consumption in office buildings
,
1994
.
[5]
Peder Wolkoff,et al.
Chemical, microbiological, health and comfort aspects of indoor air quality : state of the art in SBS
,
1992
.
[6]
Maria Loizidou,et al.
Volatile Organic Compounds in Office Buildings
,
1996
.
[7]
Maria Loizidou,et al.
Volatile Organic Compounds in Office Buildings
,
1996
.
[8]
H. Wichmann,et al.
Indoor and outdoor BTX levels in German cities.
,
2001,
The Science of the total environment.
[9]
Hai Guo,et al.
Source characterization of BTEX in indoor microenvironments in Hong Kong
,
2003
.
[10]
Christopher Yu Hang Chao,et al.
Residential indoor PM10 and PM2.5 in Hong Kong and the elemental composition
,
2002
.