Similarity Comparison Based High-Speed Pilot Protection for Transmission Line

To solve the following problem: the action speed of protection based on a phasor is restricted by the length of the filtering algorithm time window and the vulnerability to false data, a new pilot protection principle for transmission lines based on waveform similarity is proposed in this paper. By comparing the discrete point sets of current sampling values, a waveform similarity-based algorithm called the Hausdorff distance distinguishes the difference between both side currents of a protected transmission line, realizing fast identification, and removal of the fault. Based on the characteristics of the algorithm, setting methods and protection criterion are discussed. Finally, an improved Hausdorff distance algorithm is proposed to cope with false data. The effectiveness and advantages of the proposed algorithm are validated with theoretical analysis and extensive simulation test results.

[1]  Jiali He,et al.  Surge impedance relay , 2005 .

[2]  Bin Li,et al.  Circulating Unbalanced Currents of EHV/UHV Untransposed Double-Circuit Lines and Their Influence on Pilot Protection , 2014, IEEE Transactions on Power Delivery.

[3]  M. Januszewski,et al.  Overview and test results of modern pilot schemes for coordination of line distance protection relays , 2013, 2013 12th International Conference on Environment and Electrical Engineering.

[4]  Q.X. Yang,et al.  A Current Differential Relay for a 1000-kV UHV Transmission Line , 2007, IEEE Transactions on Power Delivery.

[5]  Allan Hanbury,et al.  An Efficient Algorithm for Calculating the Exact Hausdorff Distance , 2015, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[6]  Bin Li,et al.  Special Problems in Current Differential Protection Based on Bergeron Model , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[7]  Q. H. Wu,et al.  Ultra-High-Speed Directional Protection of Transmission Lines Using Mathematical Morphology , 2002, IEEE Power Engineering Review.

[8]  Zhiguo Hao,et al.  Study of Ultra-High-Speed Protection of Transmission Lines Using a Directional Comparison Scheme of Transient Energy , 2015, IEEE Transactions on Power Delivery.

[9]  Anna Wang,et al.  Difference Squared Hausdorff Distance based medical image registration , 2011, 2011 Chinese Control and Decision Conference (CCDC).

[10]  Deshu Chen,et al.  The study of sampled value differential protection , 2003, 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495).

[11]  Zhang Hong Analysis and countermeasures of problems about unusual sampling data in microprocessor-based protection , 2005 .

[12]  Sayyed Mohammad Hashemi,et al.  Impedance-Differential Protection: A New Approach to Transmission-Line Pilot Protection , 2015, IEEE Transactions on Power Delivery.

[13]  Lin Xiang-ning A NOVEL INTEGRATED MORPHOLOGY-WAVELET FILTER ALGORITHM USED FOR ULTRA-HIGH SPEED PROTECTION OF POWER SYSTEMS , 2002 .

[14]  Xindong Wu,et al.  3-D Object Retrieval With Hausdorff Distance Learning , 2014, IEEE Transactions on Industrial Electronics.

[15]  Wang Xiaoru Differential Protection Based on Calculated Power for UHV Transmission Lines , 2013 .

[16]  Guobing Song,et al.  Novel Transmission-Line Pilot Protection Based on Frequency-Domain Model Recognition , 2015, IEEE Transactions on Power Delivery.

[17]  F. Namdari,et al.  High-Speed Protection Scheme Based on Initial Current Traveling Wave for Transmission Lines Employing Mathematical Morphology , 2017, IEEE Transactions on Power Delivery.

[18]  Kai Liu,et al.  A Novel UHV/EHV Transmission-Line Pilot Protection Based on Fault Component Integrated Impedance , 2011, IEEE Transactions on Power Delivery.

[19]  Xiangning Lin,et al.  Comparative analysis on current percentage differential protections using a novel reliability evaluation criterion , 2006 .