Theoretical and experimental investigation on double basin double slope solar still

Abstract This paper presents a theoretical and experimental work performed on a double slope single basin and double basin solar still. In this work, an additional basin is incorporated with conventional single basin still to improve the performance of the double slope solar still. Single basin and double basin double slope stills are fabricated with the same area and tested under the same climatic condition. This study investigates the effect of varying the water mass in both upper and lower basin on productivity of the double basin still. In addition, the results were compared with the single basin still. From this tests (theoretical and experimental), it was found that providing an additional basin increases the productivity significantly. A good agreement was made with theoretical and experimental results. The deviation between theoretical and experimental was within 10%. Double basin still production is higher than the single basin still by 85% for the same basin condition.

[1]  A. A. El-Sebaii,et al.  Thermal performance of a triple-basin solar still , 2005 .

[2]  Mousa K. Abu-Arabi,et al.  MODELLING AND PERFORMANCE ANALYSIS OF A REGENERATIVE SOLAR DESALINATION UNIT , 2004 .

[3]  Hiroshi Tanaka A theoretical analysis of basin type solar still with flat plate external bottom reflector , 2011 .

[4]  W. E. Alnaser,et al.  Performances of single and double basin solar-stills , 2004 .

[5]  K. Kalidasa Murugavel,et al.  Comparative study of double basin and single basin solar stills , 2013 .

[6]  K. Sampathkumar,et al.  Utilization of solar water heater in a single basin solar still—An experimental study , 2012 .

[7]  Norberto Chargoy,et al.  Multi-stage, indirectly heated solar still , 1990 .

[8]  T. V. Arjunan,et al.  Active solar distillation--A detailed review , 2010 .

[9]  L. A. Kristoferson,et al.  SOLAR WATER DISTILLATION , 1986 .

[10]  T. V. Arjunan,et al.  Status of solar desalination in India , 2009 .

[11]  A. E. Kabeel,et al.  Performance of finned and corrugated absorbers solar stills under Egyptian conditions , 2011 .

[12]  N. Al Mahdi,et al.  Performance prediction of a multi-basin solar still , 1992 .

[13]  G. N. Tiwari,et al.  Transient analysis of double basin solar still , 1983 .

[14]  G. Cappelletti,et al.  An experiment with a plastic solar still , 2002 .

[15]  K. Kalidasa Murugavel,et al.  Progresses in improving the effectiveness of the single basin passive solar still , 2008 .

[16]  K. Srithar,et al.  Performance analysis of solar stills based on various factors affecting the productivity—A review , 2011 .

[17]  V. P. Bhatnagar,et al.  Analytical thermal modelling of multi-basin solar still , 1993 .

[18]  M. S. Sodha,et al.  Double basin solar still , 1980 .

[19]  K. Srithar,et al.  SINGLE BASIN SOLAR STILL WITH FIN FOR ENHANCING PRODUCTIVITY , 2008 .

[20]  S. Shukla,et al.  Thermal modeling of solar stills: an experimental validation , 2005 .

[21]  K. Kalidasa Murugavel,et al.  A review of different methods to enhance the productivity of the multi-effect solar still , 2013 .

[22]  Ali M. El-Nashar,et al.  Performance and reliability of a solar Desalination Plant during a five-year operating period , 1991 .

[23]  G. N. Tiwari,et al.  Effect of water depth on the transient performance of a double basin solar still , 1991 .

[24]  Hassan E.S. Fath,et al.  Thermal performance of a single-sloped basin still with an inherent built-in additional condenser , 2002 .

[25]  G. N. Tiwari,et al.  Performance evaluation of an active solar distillation system , 1996 .

[26]  Pierre Le Goff,et al.  Development of a rugged design of a high efficiency multi-stage solar still , 1991 .

[27]  W. E. Alnaser,et al.  Experimental comparative study of the performances of single and double basin solar-stills , 2004 .

[28]  B. A. Jubran,et al.  Parametric investigation of a double-effect solar still in comparison with a single-effect solar still , 2002 .