FRP Local Retrofit of Non-Conforming RC Beam-Column Joints

Recent seismic events have clearly confirmed the vulnerability of existing reinforced concrete (RC) structures. In particular, field observation of structures damaged by L’Aquila earthquake strongly confirmed that premature failure of partially confined (i.e. exterior) beam-column joints was one of the main causes limiting the global structural seismic capacity. Poor attention to details and a lack of adequate transverse reinforcement typically lead to premature brittle shear failure of joints. To provide support to practitioners involved in the L’Aquila reconstruction process, a proper guideline which illustrates the design of local retrofit interventions on structural and non structural elements has been edited by the Italian Civil Protection Department (DPC) and the Laboratories University Network of Seismic Engineering (ReLUIS). In particular, a viable FRP strengthening strategy to increase the seismic performances of partially confined joints (design procedure and installation steps) is widely discussed and presented in the document. To validate the strengthening system recommended in this guideline, an experimental program has been carried out on as-built and FRP strengthened full scale corner RC joints (T shaped joints). After presenting the main guideline recommendations for local strengthening of existing structures, the paper focuses on the experimental program activity; in particular, the specimen design strategy and test setup definition as well as the comparative analysis of the behavior of tested joints.

[1]  日本建築学会 Architectural Institute of Japan , 1990 .

[2]  T. Paulay,et al.  Seismic Design of Reinforced Concrete and Masonry Buildings , 1992 .

[3]  Shigeru Hakuto,et al.  Retrofitting of reinforced concrete moment resisting frames. , 1995 .

[4]  Stephen Pessiki,et al.  Implications of Experiments on the Seismic Behavior of Gravity Load Designed RC Beam-to-Column Connections , 1996 .

[5]  M. Priestley DISPLACEMENT-BASED SEISMIC ASSESSMENT OF REINFORCED CONCRETE BUILDINGS , 1997 .

[6]  C. Pantelides,et al.  Shear Strengthening of RCT-Joints Using CFRP Composites , 2000 .

[7]  Lawrence D. Reaveley,et al.  Performance-Based Evaluation of Reinforced Concrete Building Exterior Joints for Seismic Excitation , 2002 .

[8]  A. Ghobarah,et al.  Seismic rehabilitation of beam–column joint using GFRP sheets , 2002 .

[9]  Ahmed Ghobarah,et al.  Shear Strengthening of Beam-Column Joints , 2002 .

[10]  Costas P. Antonopoulos,et al.  EXPERIMENTAL INVESTIGATION OF FRP-STRENGTHENED RC BEAM-COLUMN JOINTS , 2003 .

[11]  Antonio Nanni,et al.  Erratum: "Selective upgrade of underdesigned reinforced beam-column joints using carbon fiber-reinforced concrete" (ACI Structural Journal (2004) vol. 101(5) (101-S69)) , 2004 .

[12]  A. Ghobarah,et al.  Seismic Rehabilitation of Deficient Exterior Concrete Frame Joints , 2005 .

[13]  M. Fardis,et al.  Designer's guide to EN 1998-1 and en 1998-5 Eurocode 8: Design of structures for earthquake resistance; general rules, seismic actions, design rules for buildings, foundations and retaining structures/ M.Fardis[et al.] , 2005 .

[14]  N. Null Seismic Rehabilitation of Existing Buildings , 2007 .

[15]  Andrea Prota,et al.  Comparative assessment of seismic rehabilitation techniques on a full scale 3-story RC moment frame structure , 2008 .

[16]  Alexander G. Tsonos,et al.  Effectiveness of CFRP-jackets and RC-jackets in post-earthquake and pre-earthquake retrofitting of beam–column subassemblages , 2008 .

[17]  Michael N. Fardis,et al.  Seismic Design, Assessment and Retrofitting of Concrete Buildings , 2009 .

[18]  Jaehong Kim,et al.  Joint Shear Behavior Prediction for RC Beam-Column Connections , 2011 .

[19]  K. Mosalam,et al.  Parameters for shear strength prediction of exterior beam–column joints without transverse reinforcement , 2012 .