Cooperative converter for improving the performance of grid-connected photovoltaic power plants

This study presents a new single-phase topology for the power injection system of a grid-connected photovoltaic generation system that is based on the parallel association of two voltage-source inverters: one is a three-level inverter with clamping diodes (or neutral point clamped) with a low switching frequency strategy (equal to the grid frequency) and the other is a two-level inverter which operates with a current hysteresis band strategy and an usual switching frequency (5-20 kHz). The main advantage of the proposed topology is to optimise the system design, allowing high power injection with a significant reduction of system losses (mainly switching losses) and achieving an increase of the energy injected into the grid. The performance of the proposed topology and its control algorithms are tested and validated using a laboratory prototype.

[1]  Johann W. Kolar,et al.  Parallel Connection of Two Three-Phase Three-Switch Buck-Type Unity-Power-Factor Rectifier Systems With DC-Link Current Balancing , 2007, IEEE Transactions on Industrial Electronics.

[2]  Chang-Ming Liaw,et al.  A robust hysteresis current-controlled PWM inverter for linear PMSM driven magnetic suspended positioning system , 2001, IEEE Trans. Ind. Electron..

[3]  Eftichios Koutroulis,et al.  Methodology for the design optimisation and the economic analysis of grid-connected photovoltaic systems , 2009 .

[4]  Kai Sun,et al.  A Modular Grid-Connected Photovoltaic Generation System Based on DC Bus , 2011, IEEE Transactions on Power Electronics.

[5]  José R. Rodríguez,et al.  A Survey on Neutral-Point-Clamped Inverters , 2010, IEEE Transactions on Industrial Electronics.

[6]  Emilio Olias,et al.  Overview of the state of technique for PV inverters used in low voltage grid-connected PV systems: Inverters below 10 kW , 2009 .

[7]  Gayatri Agnihotri,et al.  Inverter topologies and control structure in photovoltaic applications: A review , 2011 .

[8]  A. Ahfock,et al.  Direct current offset controller for transformerless single-phase photovoltaic grid-connected inverters , 2010 .

[9]  D. Ahmadi,et al.  A Universal Selective Harmonic Elimination Method for High-Power Inverters , 2011, IEEE Transactions on Power Electronics.

[10]  C. Xia,et al.  Neutral-Point Potential Balancing of Three-Level Inverters in Direct-Driven Wind Energy Conversion System , 2011, IEEE Transactions on Energy Conversion.

[11]  Federico Delfino,et al.  Integration of large-size photovoltaic systems into the distribution grids: a p-q chart approach to assess reactive support capability , 2010 .

[12]  Enrique Romero-Cadaval,et al.  Comparison of two power flow control strategies for photovoltaic inverters , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.

[13]  Atsushi Yona,et al.  Minimal-order observer-based coordinated control method for isolated power utility connected multiple photovoltaic systems to reduce frequency deviations , 2010 .

[14]  E. Romero-Cadaval,et al.  Cooperative converters in power electronic systems , 2010, 2010 12th Biennial Baltic Electronics Conference.

[15]  María Isabel Milanés-Montero,et al.  Power Injection System for Grid-Connected Photovoltaic Generation Systems Based on Two Collaborative Voltage Source Inverters , 2009, IEEE Transactions on Industrial Electronics.

[16]  Xiaoqiang Guo,et al.  Improved current regulation of three-phase grid-connected voltage-source inverters for distributed generation systems , 2010 .

[17]  David Infield,et al.  Impact of widespread photovoltaics generation on distribution systems , 2007 .

[18]  Freddy Chan,et al.  Reliability Estimation of Three Single-Phase Topologies in Grid-Connected PV Systems , 2011, IEEE Transactions on Industrial Electronics.