Intracorneal ring segments for keratoconus correction: Long‐term follow‐up

PURPOSE: To evaluate long‐term results and stability of intracorneal ring segment (Intacs) implantation for keratoconus correction. SETTING: Vissum, Instituto Oftalmológico de Alicante and University of Miguel Hernandez, Alicante, Spain. METHODS: This retrospective study comprised 13 eyes operated on between April 2000 and December 2001 that had Intacs implantation for keratoconus correction. The outcomes were evaluated at 6, 12, 24, and 36 months in all eyes and at 48 months (6 eyes). RESULTS: Mean best spectacle‐corrected visual acuity (BSCVA) increased from 0.46 (20/50) preoperatively to 0.66 (20/30) postoperatively (P≤.001). Mean decrease of inferior‐superior (I‐S) asymmetry was 2.81 diopters (D) (P≤.02), and the average K‐value was 3.13 D (P≤.001). Mean difference between 6 and 36 months (stability) showed no significant difference regarding BSCVA (P≤.5) and I‐S asymmetry (P≤.6). Although a significant increase was noticed in the average K by 1.67 D (P≤.002), at 36 months it did not reach the initial preoperative values. CONCLUSION: Intacs increased the BSCVA and decreased I‐S asymmetry with stability up to 36 months. In spite of the decrease of the K‐values at 6 months, a further significant increase was detected 36 months after surgery.

[1]  J. Krachmer,et al.  Keratoconus and related noninflammatory corneal thinning disorders. , 1984, Survey of ophthalmology.

[2]  D. Evensen,et al.  Effects of intrastromal corneal ring size and thickness on corneal flattening in human eyes. , 1991, Refractive & corneal surgery.

[3]  J. Alió,et al.  One or 2 Intacs segments for the correction of keratoconus , 2005, Journal of cataract and refractive surgery.

[4]  J. Alió,et al.  Changes in keratoconic corneas after intracorneal ring segment explantation and reimplantation. , 2004, Ophthalmology.

[5]  Z. Tunc,et al.  Anneaux intracornéens pour le traitement de l'astigmatisme asymétrique du kératocône. Recul de plus de deux ans. , 2003 .

[6]  J. Alió,et al.  Intracorneal asymmetrical rings for keratoconus: where should the thicker segment be implanted? , 2006, Journal of refractive surgery.

[7]  J Colin,et al.  Correcting keratoconus with intracorneal rings. , 2000, Journal of cataract and refractive surgery.

[8]  N. Maeda,et al.  Changes in anterior and posterior corneal curvatures in keratoconus. , 2000, Ophthalmology.

[9]  J. Ruckhofer,et al.  Clinical characteristics of lamellar channel deposits after implantation of Intacs , 2000, Journal of cataract and refractive surgery.

[10]  Z. Tunc,et al.  Anneaux intracornéens (INTACS) pour le traitement de l'astigmatisme asymétrique du kératocône , 2008 .

[11]  F. Price Penetrating keratoplasty for keratoconus , 1992, The British journal of ophthalmology.

[12]  Jorge L. Alió,et al.  Analysis of results related to good and bad outcomes of Intacs implantation for keratoconus correction , 2006, Journal of cataract and refractive surgery.