Tensile bond strength between custom tray and elastomeric impression material.

The aim of this study was to investigate how to achieve sufficient and stable adhesive strength between impression material and tray. Impression materials were molded between autopolymerizing resin columns, and tensile strength was measured as a function of these factors: tray storage time (1, 2, 4, 7, and 10 days), adhesive drying time (0, 1, 5, 10, and 15 minutes), and tray surface roughness (air abrasion, bur-produced roughness, and no treatment). Tensile bond strength was not affected by tray storage time throughout the entire evaluation period of 10 days. As for tray adhesive drying time, Reprosil and Exaimplant yielded extremely low values for drying times of 10 minutes or less (P<0.05), while Imprint II and Impregum were not influenced by drying time. Vinyl polysiloxane achieved the highest adhesive strength with bur-produced roughness, which was significantly higher than with air abrasion or no treatment (P<0.05), whereas polyether achieved the lowest value with bur-produced roughness (P<0.05). It was concluded that surface treatment of custom tray should be adapted to the type of impression material used to achieve optimum bond strength.

[1]  Y. Akagawa,et al.  New surface modification of titanium implant with phospho-amino acid. , 2005, Dental materials journal.

[2]  Yasuhiro Tanimoto,et al.  Influence of cortical bone quality on stress distribution in bone around dental implant. , 2005, Dental materials journal.

[3]  P. Vigolo,et al.  An evaluation of impression techniques for multiple internal connection implant prostheses. , 2004, The Journal of prosthetic dentistry.

[4]  S. Okawa,et al.  Morphological and chemical characterizations of the interface of a hydroxyapatite-coated implant. , 2004, Dental materials journal.

[5]  M. A. Abdullah,et al.  The effect of custom tray material type and fabrication technique on tensile bond strength of impression material adhesive systems. , 2003, Journal of oral rehabilitation.

[6]  Leslie Howe,et al.  Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. , 2003, The Journal of prosthetic dentistry.

[7]  M A Iglesia,et al.  A method aimed at achieving passive fit in implant prostheses: case report. , 2001, The International journal of prosthodontics.

[8]  P. Vigolo,et al.  In vitro comparison of master cast accuracy for single-tooth implant replacement. , 2000, The Journal of prosthetic dentistry.

[9]  Alvin G. Wee Comparison of impression materials for direct multi-implant impressions. , 2000, The Journal of prosthetic dentistry.

[10]  Alvin G. Wee,et al.  Evaluation of the accuracy of solid implant casts. , 1998, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[11]  S. Minagi,et al.  Efficacy of tray adhesives for the adhesion of elastomer rubber impression materials to impression modeling plastics for border molding. , 1998, The Journal of prosthetic dentistry.

[12]  T Jemt,et al.  Prosthesis misfit and marginal bone loss in edentulous implant patients. , 1996, The International journal of oral & maxillofacial implants.

[13]  B R Lang,et al.  Measuring fit at the implant prosthodontic interface. , 1996, The Journal of prosthetic dentistry.

[14]  C. Aparicio A new method for achieving passive fit of an interim restoration supported by Brånemark implants: a technical note. , 1995, The International journal of oral & maxillofacial implants.

[15]  A B Carr,et al.  Comparison of impression techniques for a five-implant mandibular model. , 1992, The International journal of oral & maxillofacial implants.

[16]  G. B. Pelleu,et al.  Dimensional stability of autopolymerizing acrylic resin impression trays. , 1986, The Journal of prosthetic dentistry.

[17]  B. Pereira,et al.  Bond strength of three nonaqueous elastomeric impression materials to a light-activated resin tray. , 1992, The International journal of prosthodontics.

[18]  D G Drennon,et al.  The effect of tray selection on the accuracy of elastomeric impression materials. , 1990, The Journal of prosthetic dentistry.

[19]  G. Zarb,et al.  Tissue integrated dental prostheses. , 1985, Quintessence international.