An impedance biosensor for monitoring cancer cell attachment, spreading and drug-induced apoptosis

Abstract In the last three decades, Electrical Cell-substrate Impedance Sensing (ECIS) has emerged as a powerful technique for in vitro cellular research and preclinical testing. In this study, a cell-based impedance biosensor based on ECIS technique, which integrates microelectrode arrays with a small culture chamber has been developed for monitoring the attachment, spreading and drug-induced apoptosis of very few MCF-7 breast cancer cells. It was found out that cell spreading caused a significant increase of impedance magnitude in the frequency range between 10 kHz and 100 kHz and also pronounced phase shift. Using an electrical equivalent circuit to model the measured spectra, the morphological change of cells was analyzed. Cell spreading induced a slight decrease of membrane capacitance of 2% and a prominent increase of membrane resistance of 57% within incubating for nearly one day. For pharmaceutical assessment, the cells were treated with different concentrations of an anti-cancer drug (Cisplatin) in the range from 10 μM to 50 μM. We observed a fast decrease of impedance magnitude within the initial 4 h of treatment with concentrations of 25 μM and 50 μM. The results derived from this study demonstrated the usability of cell-based impedance microbiosensors in cell biology and cancer research.

[1]  Jongin Hong,et al.  Electrical cell-substrate impedance sensing as a non-invasive tool for cancer cell study. , 2011, The Analyst.

[2]  R. McGuinness Impedance-based cellular assay technologies: recent advances, future promise. , 2007, Current opinion in pharmacology.

[3]  Liju Yang,et al.  Interdigitated microelectrode-based microchip for electrical impedance spectroscopic study of oral cancer cells , 2011, Biomedical microdevices.

[4]  N. Balaban,et al.  Adhesion-dependent cell mechanosensitivity. , 2003, Annual review of cell and developmental biology.

[5]  Miqin Zhang,et al.  Cellular impedance biosensors for drug screening and toxin detection. , 2007, The Analyst.

[6]  I. Giaever,et al.  Micromotion of mammalian cells measured electrically. , 1991, Proceedings of the National Academy of Sciences of the United States of America.

[7]  K. Marx,et al.  Quartz crystal microbalance biosensor study of endothelial cells and their extracellular matrix following cell removal: Evidence for transient cellular stress and viscoelastic changes during detachment and the elastic behavior of the pure matrix. , 2005, Analytical biochemistry.

[8]  V. Ntziachristos Fluorescence molecular imaging. , 2006, Annual review of biomedical engineering.

[9]  B. Gumbiner,et al.  Cell Adhesion: The Molecular Basis of Tissue Architecture and Morphogenesis , 1996, Cell.

[10]  I. Giaever,et al.  Monitoring fibroblast behavior in tissue culture with an applied electric field. , 1984, Proceedings of the National Academy of Sciences of the United States of America.

[11]  Julian A. T. Dow,et al.  Single cell mobility and adhesion monitoring using extracellular electrodes , 1991 .

[12]  Takeshi Suzuki,et al.  Recent Advances in Fluorescent Labeling Techniques for Fluorescence Microscopy , 2007, Acta histochemica et cytochemica.

[13]  S. Ingebrandt,et al.  Field-effect devices for detecting cellular signals. , 2009, Seminars in cell & developmental biology.

[14]  Zhenyu Guo,et al.  A review of electrical impedance techniques for breast cancer detection. , 2003, Medical engineering & physics.

[15]  Xiao Xu,et al.  The application of cell‐based label‐free technology in drug discovery , 2008, Biotechnology journal.

[16]  Wei Zheng,et al.  Application of real-time cell electronic sensing (RT-CES) technology to cell-based assays. , 2004, Assay and drug development technologies.

[17]  Jianhua Huang,et al.  Longitudinal confocal microscopy imaging of solid tumor destruction following adoptive T cell transfer , 2013, Oncoimmunology.

[18]  B. Barlogie,et al.  Flow cytometry in clinical cancer research. , 1983, Cancer research.

[19]  Tien Anh Nguyen,et al.  Microfluidic chip with integrated electrical cell-impedance sensing for monitoring single cancer cell migration in three-dimensional matrixes. , 2013, Analytical chemistry.

[20]  C. Mathers,et al.  Cancer incidence and mortality worldwide: Sources, methods and major patterns in GLOBOCAN 2012 , 2015, International journal of cancer.

[21]  Qingjun Liu,et al.  Impedance studies of bio-behavior and chemosensitivity of cancer cells by micro-electrode arrays. , 2009, Biosensors & bioelectronics.

[22]  Andreas Hierlemann,et al.  Impedance characterization and modeling of electrodes for biomedical applications , 2005, IEEE Transactions on Biomedical Engineering.

[23]  Sergio Martinoia,et al.  Cultured neurons coupled to microelectrode arrays: circuit models, simulations and experimental data , 2004, IEEE Transactions on Biomedical Engineering.