Evaluation of an EIT reconstruction algorithm using finite difference human thorax models as phantoms.

A finite difference model of the human thorax with 113,400 control volumes (nodes) based on ECG gated MRI images was used to evaluate the Sheffield DAS-01P EIT system. Sixteen simulated electrode positions equally spaced around the thorax model at approximately the fourth intercostals space level were selected. Pairs of adjacent positions were excited sequentially by injecting current in a manner similar to that used by the Sheffield DAS-01P EIT system. The resulting voltages on the non-excited electrode positions were calculated and used to reconstruct the image using the Sheffield filtered back projection algorithm. By changing the resistivities of the lungs, the ventricles and the atria over a range of 1% to 40%, the resulting changes in the images were quantified by measuring the average resistivity change over a region defined automatically by two thresholds, 40% or 80% of the average of the first four pixels with the largest change. The results show that the changes observed in the images are consistently less than the changes in the model, but changed in a nearly linear manner as a function of resistivity in the model. For 40% resistivity changes in the model for right lung, right ventricle and right atrium, the observed resistivity changes in the region of interest (ROI, defined by the 80% threshold) of the images are 32% for the right lung, 11% for the right ventricle and 5.5% for the right atrium, which suggests strong volume dependence of EIT imaging. The effect of structural (size) change between end diastole and end systole was also studied, which showed large resistivity changes caused in the heart region of the constructed image. The study demonstrates that the Sheffield DAS-01P EIT reconstruction algorithm tracks the change occurring in the lungs most closely and with proper scaling may be used to observe physiological changes.

[1]  R. Patterson,et al.  Multiple sources of the impedance cardiogram based on 3-D finite difference human thorax models , 1995, IEEE Transactions on Biomedical Engineering.

[2]  D C Barber,et al.  Applications of applied potential tomography (APT) in respiratory medicine. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[3]  B H Brown,et al.  The Sheffield data collection system. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[4]  Gerhard Hellige,et al.  Thoracic electrical impedance tomographic measurements during volume controlled ventilation-effects of tidal volume and positive end-expiratory pressure , 1999, IEEE Transactions on Medical Imaging.

[5]  G Hahn,et al.  Gravity-dependent phenomena in lung ventilation determined by functional EIT. , 1996, Physiological measurement.

[6]  R. Sadleir,et al.  Quantification of blood volume by electrical impedance tomography using a tissue-equivalent phantom. , 1998, Physiological measurement.

[7]  T. J. Noble,et al.  Diuretic induced change in lung water assessed by electrical impedance tomography. , 2000, Physiological measurement.

[8]  B. Eyüboğlu,et al.  Application of electrical impedance tomography in diagnosis of emphysema--a clinical study. , 1995, Physiological measurement.

[9]  D C Barber,et al.  Applied potential tomography: a new technique for monitoring pulmonary function. , 1988, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[10]  I Frerichs,et al.  Electrical impedance tomography (EIT) in applications related to lung and ventilation: a review of experimental and clinical activities. , 2000, Physiological measurement.

[11]  D S Holder,et al.  Use of polyacrylamide gels in a saline-filled tank to determine the linearity of the Sheffield Mark 1 electrical impedance tomography (EIT) system in measuring impedance disturbances. , 1994, Physiological measurement.

[12]  D C Barber,et al.  Fast reconstruction of resistance images. , 1987, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[13]  G.J. Saulnier,et al.  ACT3: a high-speed, high-precision electrical impedance tomograph , 1991, IEEE Transactions on Biomedical Engineering.

[14]  A Adler,et al.  Monitoring changes in lung air and liquid volumes with electrical impedance tomography. , 1997, Journal of applied physiology.

[15]  G. Hahn,et al.  Changes in the thoracic impedance distribution under different ventilatory conditions. , 1995, Physiological measurement.

[16]  B H Brown,et al.  Monitoring patients with left ventricular failure by electrical impedance tomography , 1999, European journal of heart failure.