Evaluating the High Frequency Behavior of the Modified Grounding Scheme in Wind Farms

Wind generators are exposed to numerous destructive forces such as lightning and are therefore vulnerable to these phenomena. To evaluate the transient behavior of a wind power plant during direct and indirect strikes, modeling of all relevant components is required. Among the protective and control components of wind turbines, the grounding system is the most important element for protection against lightning strikes. This paper examines the impact of nonlinear soil ionization behavior and frequency dependency on a wind turbine in order to model a sufficient protection scheme to reduce overvoltage and make the system tolerable against transitions. The high frequency models of other equipment such as transformers, horizontal conductors, vertical rods, surge arresters and underground cables must also be taken into account to design the grounding system. Our Proposed Modified Grounding Scheme (PMGS) is to reduce the maximum transient overvoltages. We simulate the model in a restructured version of the Electromagnetic Transient Program (EMTP-RV) software to examine the effectiveness of the system. We then apply the simulated results to pair of turbines that are interconnected with a frequency-dependent cable. We carry out the simulation for direct and indirect lightning strikes. The results indicate that the MGS can lead to considerably more than a 50% reduction in transient voltages for lightning and thus leads to more reliable networks.

[1]  J. Tykocki,et al.  Pareto - ABC Analysis of High Voltage Single Core Cable Temperature , 2014 .

[2]  Bjorn Gustavsen,et al.  Inclusion of Field-Solver-Based Tower Footing Grounding Models in Electromagnetic Transient Programs , 2015, IEEE Transactions on Industry Applications.

[3]  Rajeev Thottappillil,et al.  An improved transmission-line model of grounding system , 2001 .

[4]  B. Glushakow,et al.  Effective Lightning Protection For Wind Turbine Generators , 2007, IEEE Transactions on Energy Conversion.

[5]  Enzo Baccarelli,et al.  Energy-Efficient Adaptive Resource Management for Real-Time Vehicular Cloud Services , 2019, IEEE Transactions on Cloud Computing.

[6]  Sung-Hoon Ahn,et al.  Practical aspects of a condition monitoring system for a wind turbine with emphasis on its design, system architecture, testing and installation , 2010 .

[7]  E. Sunde Earth conduction effects in transmission systems , 1949 .

[8]  Sajal K. Das,et al.  Towards a realistic model for failure propagation in interdependent networks , 2016, 2016 International Conference on Computing, Networking and Communications (ICNC).

[9]  B. Vahidi,et al.  Optimal Surge Arrester Parameter Estimation Using a PSO-Based Multiobjective Approach , 2013, IEEE Transactions on Power Delivery.

[10]  Inmaculada Zamora,et al.  Wind farm grounding system design for transient currents , 2011 .

[11]  F. Rachidi,et al.  On the Measurement of the Grounding Impedance of Tall Wind Turbines , 2017 .

[12]  Bjorn Gustavsen,et al.  Investigation of the Overvoltage and Fast Transient Phenomena on Transformer Terminals by Taking Into Account the Grounding Effects , 2015, IEEE Transactions on Industry Applications.

[13]  Nikos D. Hatziargyriou,et al.  A simplified formula of a surge characteristics of a long grounding conductor , 2003 .

[14]  A. Said,et al.  A Proper Design of Wind Turbine Grounding Systems under Lightning , 2014 .

[15]  T. Funabashi,et al.  Transient analysis on wind farm suffered from lightning , 2004, 39th International Universities Power Engineering Conference, 2004. UPEC 2004..

[16]  Ioannis F. Gonos,et al.  Impact study of short-circuit calculation methods on the design of a wind farm's grounding system , 2014 .

[17]  Joao P. S. Catalao,et al.  Protection of interconnected wind turbines against lightning effects: Overvoltages and electromagnetic transients study , 2012 .

[18]  Yoshihiro Baba,et al.  Lightning surge analysis on wind farm with interconnecting grounding wire using circuit model for vertical conductor , 2015, 2015 50th International Universities Power Engineering Conference (UPEC).

[19]  L. Grcev,et al.  Time- and Frequency-Dependent Lightning Surge Characteristics of Grounding Electrodes , 2009, IEEE Transactions on Power Delivery.

[20]  D. Romero,et al.  Behaviour of the Wind-Turbines Under Lightning Strikes Including Nonlinear Grounding System , 2004 .

[21]  T. Funabashi,et al.  Surge Analysis on Wind Farm When Winter Lightning Strikes , 2008, IEEE Transactions on Energy Conversion.

[22]  Mohamed A. Izzularab,et al.  High-frequency modeling of Zafarana wind farm and reduction of backflow current-overvoltages , 2014 .

[23]  Kazuo Yamamoto,et al.  Transient Grounding Characteristics of an Actual Wind Turbine Generator System at a Low-resistivity Site , 2010 .

[24]  A. Nasiri,et al.  Wind turbine grounding system frequency-dependent modeling for lightning transient studies , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.

[25]  J. Martí,et al.  Accuarte Modelling of Frequency-Dependent Transmission Lines in Electromagnetic Transient Simulations , 1982, IEEE Transactions on Power Apparatus and Systems.

[26]  Joao P. S. Catalao,et al.  Protection of wind energy systems against the indirect effects of lightning , 2011 .

[27]  Ioannis A. Stathopulos,et al.  Research and applications of ground enhancing compounds in grounding systems , 2017 .

[28]  Cheng-Chien Kuo,et al.  Wind energy dispatch considering environmental and economic factors , 2010 .

[29]  M. Popov,et al.  On high-frequency circuit equivalents of a vertical ground rod , 2005, IEEE Transactions on Power Delivery.

[30]  Transient Recovery Voltage Investigation in the Application of 15 kV Circuit Breaker Failure , 2005 .

[31]  Salvatore Celozzi,et al.  Transient response of grounding systems of wind turbines under lightning strikes , 2014, 2014 International Symposium on Electromagnetic Compatibility.

[32]  B. Gustavsen,et al.  Parameterized Macromodeling for Efficient Analysis of Wideband Tower Grounding Structures , 2016, IEEE Transactions on Power Delivery.

[33]  Mahmoud N. Ali,et al.  A novel lightning protection technique of wind turbine components , 2015 .

[34]  Jemal H. Abawajy,et al.  Economical and environmental operation of smart networked microgrids under uncertainties using NSGA-II , 2016, 2016 24th International Conference on Software, Telecommunications and Computer Networks (SoftCOM).

[35]  S Sekioka,et al.  Analytical Surveys of Transient and Frequency-Dependent Grounding Characteristics of a Wind Turbine Generator System on the Basis of Field Tests , 2010, IEEE Transactions on Power Delivery.

[36]  M. Heimbach,et al.  Grounding System Analysis in Transients Programs Applying Electromagnetic Field Approach , 1997, IEEE Power Engineering Review.

[37]  A. Mekhaldi,et al.  Time-Domain Modeling of Grounding Systems’ Impulse Response Incorporating Nonlinear and Frequency-Dependent Aspects , 2018, IEEE Transactions on Electromagnetic Compatibility.

[38]  Reza Kazemi,et al.  Wideband Modeling of Large Grounding Systems to Interface With Electromagnetic Transient Solvers , 2014, IEEE Transactions on Power Delivery.