Planar Hall magnetoresistive aptasensor for thrombin detection.

The use of aptamer-based assays is an emerging and attractive approach in disease research and clinical diagnostics. A sensitive aptamer-based sandwich-type sensor is presented to detect human thrombin using a planar Hall magnetoresistive (PHR) sensor in cooperation with superparamagnetic labels. A PHR sensor has the great advantages of a high signal-to-noise ratio, a small offset voltage and linear response in the low-field region, allowing it to act as a high-resolution biosensor. In the system presented here, the sensor has an active area of 50 µm × 50 µm with a 10-nm gold layer deposited onto the sensor surface prior to the binding of thiolated DNA primary aptamer. A polydimethylsiloxane well of 600-µm radius and 1-mm height was prepared around the sensor surface to maintain the same specific area and volume for each sensor. The sensor response was traced in real time upon the addition of streptavidin-functionalized magnetic labels on the sensor. A linear response to the thrombin concentration in the range of 86 pM-8.6 µM and a lower detection limit down to 86 pM was achieved by the proposed present method with a sample volume consumption of 2 µl. The proposed aptasensor has a strong potential for application in clinical diagnosis.

[1]  T. Q. Hung,et al.  Planar Hall resistance ring sensor based on NiFe/Cu/IrMn trilayer structure , 2013 .

[2]  P. He,et al.  A host-guest-recognition-based electrochemical aptasensor for thrombin detection. , 2012, Biosensors & bioelectronics.

[3]  Gil U. Lee,et al.  A biosensor based on magnetoresistance technology. , 1998, Biosensors & bioelectronics.

[4]  S. Karpatkin,et al.  Thrombin induces tumor growth, metastasis, and angiogenesis: Evidence for a thrombin-regulated dormant tumor phenotype. , 2006, Cancer cell.

[5]  M. Tian,et al.  Aptamer/thrombin/aptamer-AuNPs sandwich enhanced surface plasmon resonance sensor for the detection of subnanomolar thrombin. , 2013, Biosensors & bioelectronics.

[6]  Namhyun Choi,et al.  Highly sensitive detection of thrombin using SERS-based magnetic aptasensors. , 2013, Biosensors & bioelectronics.

[7]  Ronald W Davis,et al.  Sensitive giant magnetoresistive-based immunoassay for multiplex mycotoxin detection. , 2010, Biosensors & bioelectronics.

[8]  A. Baeumner,et al.  Aptamer sandwich assays: human α-thrombin detection using liposome enhancement , 2010, Analytical and bioanalytical chemistry.

[9]  V. Pott,et al.  Detection of a single magnetic microbead using a miniaturized silicon Hall sensor , 2002 .

[10]  M. Goto,et al.  Microplate assay for aptamer-based thrombin detection using a DNA-enzyme conjugate based on histidine-tag chemistry. , 2012, Analytical biochemistry.

[11]  D. Kriz,et al.  Magnetic Transducers in Biosensors and Bioassays , 1999 .

[12]  G. Kurlyandskaya,et al.  Magnetic Dynabeads detection by sensitive element based on giant magnetoimpedance. , 2005, Biosensors & bioelectronics.

[13]  G. Evtugyn,et al.  Polyphenothiazine Modified Electrochemical Aptasensor for Detection of Human α‐Thrombin , 2007 .

[14]  Yanli Sun,et al.  A sensitive nanoporous gold-based electrochemical aptasensor for thrombin detection. , 2010, Colloids and surfaces. B, Biointerfaces.

[15]  Jaein Lim,et al.  An organic substrate based magnetoresistive sensor for rapid bacteria detection. , 2013, Biosensors & bioelectronics.

[16]  Luke P. Lee,et al.  Aptamer-based SERRS sensor for thrombin detection. , 2008, Nano letters.

[17]  Ji Ji,et al.  An aptamer-based biosensor for sensitive thrombin detection , 2009 .

[18]  Song Zhang,et al.  Magnetic relaxation switch and colorimetric detection of thrombin using aptamer-functionalized gold-coated iron oxide nanoparticles. , 2011, Analytica chimica acta.

[19]  Huang-Hao Yang,et al.  A graphene platform for sensing biomolecules. , 2009, Angewandte Chemie.

[20]  S. Anandakumar,et al.  Micro-magnetometry for susceptibility measurement of superparamagnetic single bead , 2012 .

[21]  G. A. Prinz,et al.  Detection of a micron-sized magnetic sphere using a ring-shaped anisotropic magnetoresistance-based sensor: A model for a magnetoresistance-based biosensor , 2002 .

[22]  Ding Li,et al.  Giant magnetoimpedance-based microchannel system for quick and parallel genotyping of human papilloma virus type 16/18 , 2010 .

[23]  Yingwei Zhang,et al.  A novel fluorescent aptasensor for thrombin detection: using poly(m-phenylenediamine) rods as an effective sensing platform. , 2011, Chemical communications.

[24]  Feng Liu,et al.  Amplified QCM-D biosensor for protein based on aptamer-functionalized gold nanoparticles. , 2010, Biosensors & bioelectronics.

[25]  Dawei Huang,et al.  Time-resolved fluorescence aptamer-based sandwich assay for thrombin detection. , 2010, Talanta.

[26]  P. He,et al.  An Aptamer-Based Protein Biosensor by Detecting the Amplified Impedance Signal , 2006 .

[27]  A Torti,et al.  Conditions for efficient on-chip magnetic bead detection via magnetoresistive sensors. , 2013, Biosensors & bioelectronics.

[28]  Hugo Ferreira,et al.  Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors (invited) , 2003 .