Metaphyseal debonding of the Corail collarless cementless stem: REPORT OF 18 CASES AND CASE‐CONTROL STUDY
暂无分享,去创建一个
[1] M. Bonnin,et al. Impact of a learning curve on the survivorship of 4802 cementless total hip arthroplasties. , 2016, The bone & joint journal.
[2] O Cantin,et al. Compared fixation and survival of 280 lateralised vs 527 standard cementless stems after two years (1-7). , 2015, Orthopaedics & traumatology, surgery & research : OTSR.
[3] G. Flivik,et al. Design modifications of the uncemented Furlong hip stem result in minor early subsidence but do not affect further stability , 2014, Acta orthopaedica.
[4] P. Neyret,et al. Does a collar improve the immediate stability of uncemented femoral hip stems in total hip arthroplasty? A bilateral comparative cadaver study. , 2011, The Journal of arthroplasty.
[5] J. Vidalain. Twenty-year results of the cementless Corail stem , 2011, International Orthopaedics.
[6] H. Migaud,et al. Radiographic preoperative templating of extra-offset cemented THA implants: how reliable is it and how does it affect survival? , 2010, Orthopaedics & traumatology, surgery & research : OTSR.
[7] W. Hozack,et al. Introduction: Advances in surgical technology supplement. , 2008, The Journal of arthroplasty.
[8] E. Tsiridis,et al. Posterior longitudinal split osteotomy for femoral component extraction in revision total hip arthroplasty. , 2008, The Journal of arthroplasty.
[9] S. Vollset,et al. Medium- and long-term performance of 11,516 uncemented primary femoral stems from the Norwegian arthroplasty register. , 2007, The Journal of bone and joint surgery. British volume.
[10] M. Froimson,et al. Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review. , 2007, The Journal of arthroplasty.
[11] G. Lyritis,et al. The long-term clinical relevance of calcar atrophy caused by stress shielding in total hip arthroplasty: a 10-year, prospective, randomized study. , 2004, The Journal of arthroplasty.
[12] O. Reikerås,et al. Excellent results of HA coating on a grit-blasted stem: 245 patients followed for 8-12 years , 2003, Acta orthopaedica Scandinavica.
[13] M A Ritter,et al. Comparison of collared and collarless femoral components in primary uncemented total hip arthroplasty. , 1997, The Journal of arthroplasty.
[14] B. Espehaug,et al. Early aseptic loosening of uncemented femoral components in primary total hip replacement. A review based on the Norwegian Arthroplasty Register. , 1995, The Journal of bone and joint surgery. British volume.
[15] L. Dorr,et al. Structural and cellular assessment of bone quality of proximal femur. , 1993, Bone.
[16] C. Engh,et al. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. , 1990, Clinical orthopaedics and related research.
[17] H. Amstutz,et al. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. , 1979, Clinical orthopaedics and related research.