Ultrasound propagation in cortical bone: Axial transmission and backscattering simulations

Cortical bone is a heterogeneous, composite medium with a porosity from 5-10%. The characterization of cortical bone using ultrasonic techniques is a complicated procedure especially in numerical studies as several assumptions must be made to describe the concentration and size of pores. This study presents numerical simulations of ultrasound propagation in two-dimensional numerical models of cortical bone to investigate the effect of porosity on: a) the propagation of the first arriving signal (FAS) velocity using the axial transmission method, and b) the displacement and scattering amplitude in the backward direction. The excitation frequency 1 MHz was used and different receiving positions were examined to provide a variation profile of the examined parameters along cortical bone. Cortical porosity was simulated using ellipsoid scatterers and the concentrations of 0-10% were examined. The results indicate that the backscattering method is more appropriate for the evaluation of cortical porosity in comparison to the axial transmission method.

[1]  Jussi Timonen,et al.  Assessment of the cortical bone thickness using ultrasonic guided waves: modelling and in vitro study. , 2007, Ultrasound in medicine & biology.

[2]  Maryline Talmant,et al.  Ultrasonically determined thickness of long cortical bones: Three-dimensional simulations of in vitro experiments. , 2007, The Journal of the Acoustical Society of America.

[3]  Dimitrios I. Fotiadis,et al.  Computational study of the influence of callus porosity on ultrasound propagation in healing bones , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  Pascal Laugier,et al.  Potential of first arriving signal to assess cortical bone geometry at the Hip with QUS: a model based study. , 2010, Ultrasound in medicine & biology.

[5]  Tommi Kärkkäinen,et al.  Guided ultrasonic waves in long bones: modelling, experiment and in vivo application. , 2002, Physiological measurement.

[6]  Maryline Talmant,et al.  Ultrasonically determined thickness of long cortical bones: two-dimensional simulations of in vitro experiments. , 2007, The Journal of the Acoustical Society of America.

[7]  Sabina Gheduzzi,et al.  Ultrasound transmission loss across transverse and oblique bone fractures: an in vitro study. , 2008, Ultrasound in medicine & biology.

[8]  Kay Raum,et al.  Application of an effective medium theory for modeling ultrasound wave propagation in healing long bones. , 2014, Ultrasonics.

[9]  Pascal Laugier,et al.  Ultrasound to Assess Bone Quality , 2014, Current Osteoporosis Reports.

[10]  Emmanuel Bossy,et al.  Numerical Methods for Ultrasonic Bone Characterization , 2011 .

[11]  Pascal Laugier,et al.  Bone quantitative ultrasound , 2011 .

[12]  Pascal Laugier,et al.  Influence of porosity, pore size, and cortical thickness on the propagation of ultrasonic waves guided through the femoral neck cortex: a simulation study , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[13]  E. Bossy,et al.  Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study. , 2002, The Journal of the Acoustical Society of America.

[14]  W. Marsden I and J , 2012 .