Development of a mobile pulse waveform analyzer for cardiovascular health monitoring

Noninvasive pulse waveforms contain rich pathophysiological information of cardiovascular system. It is hereby a tradition of interest to implement risk stratification by pulse waveform monitoring and analysis. In contrast to conventional computer- or network-based solutions, we attempt to accomplish pulse waveform monitoring and analysis within a self-contained mobile platform. It adopts a compact biosensor for pulse waveform acquisition. The collected signals are then submitted to a core board for pulse waveform processing and analysis. In addition, the core board coordinates user interaction and network communication too. Such compact pulse waveform analyzer is of great help for cardiovascular health monitoring at home. A carefully designed evaluation has been undertaken within our research group. The results confirmed its prospect in home healthcare.

[1]  T. Ozawa,et al.  Accuracy of a continuous blood pressure monitor based on arterial tonometry. , 1993, Hypertension.

[2]  Peng Un Mak,et al.  A novel intelligent sphygmogram analyzer for health monitoring of cardiovascular system , 2005, Expert Syst. Appl..

[3]  W. Young,et al.  Infinite number of solutions to the hemodynamic inverse problem. , 2001, American journal of physiology. Heart and circulatory physiology.

[4]  P. Verdonck,et al.  Development and modelling of arterial applanation tonometry: a review. , 2002, Technology and health care : official journal of the European Society for Engineering and Medicine.

[5]  W. Nichols,et al.  McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles , 1998 .

[6]  Feng Li,et al.  [The design and applications of a non-invasive intelligent detector for cardiovascular functions]. , 2006, Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation.

[7]  S. Tanaka,et al.  Noninvasive measurement of instantaneous, radial artery blood pressure , 2005, IEEE Engineering in Medicine and Biology Magazine.

[8]  A. Demaria,et al.  Development and validation of a noninvasive method to determine arterial pressure and vascular compliance. , 1997, The American journal of cardiology.

[9]  A Noordergraaf,et al.  Constructive and destructive addition of forward and reflected arterial pulse waves. , 2001, American journal of physiology. Heart and circulatory physiology.

[10]  W. B. Murray,et al.  The peripheral pulse wave: Information overlooked , 1996, Journal of clinical monitoring.

[11]  Jing Bai,et al.  A portable ECG and blood pressure telemonitoring system. , 1999, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[12]  Bao Naikeng Research of multi point pulse wave computer measurement system using PVDF , 1999 .

[13]  G Pfurtscheller,et al.  A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function. , 1998, Computers in biology and medicine.

[14]  Giandomenico Nollo,et al.  Toward personal eHealth in cardiology. Results from the EPI-MEDICS telemedicine project. , 2005, Journal of electrocardiology.

[15]  J. V. van Lieshout,et al.  Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger , 2005, Experimental physiology.

[16]  Arshed A Quyyumi,et al.  Surrogate Markers for Cardiovascular Disease: Functional Markers , 2004, Circulation.

[17]  A. Cipriano,et al.  Estimation of cardiac function from computer analysis of the arterial pressure waveform , 1998, IEEE Transactions on Biomedical Engineering.

[18]  A Noordergraaf,et al.  Differential effects of wave reflections and peripheral resistance on aortic blood pressure: a model-based study. , 1994, The American journal of physiology.

[19]  G Martinelli,et al.  Telecardiology: One-lead electrocardiogram monitoring and nurse triage in chronic heart failure , 2005, Journal of telemedicine and telecare.

[20]  Michael E Andrew,et al.  Digital pulse contour analysis: investigating age-dependent indices of arterial compliance , 2005, Physiological measurement.

[21]  J. Cohn,et al.  Noninvasive pulse wave analysis for the early detection of vascular disease. , 1995, Hypertension.

[22]  L. R. John Forward electrical transmission line model of the human arterial system , 2006, Medical and Biological Engineering and Computing.

[23]  Chunxiao Chen,et al.  [The research of noninvasive cardiovascular diagnosis and test instrument]. , 2003, Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi.

[24]  Xinsheng Li,et al.  Simulation study of the cardiovascular functional status in hypertensive situation , 2002, Comput. Biol. Medicine.