Novel Automated Approach to Predict the Outcome of Laser Peripheral Iridotomy for Primary Angle Closure Suspect Eyes Using Anterior Segment Optical Coherence Tomography

Develop an algorithm to predict the success of laser peripheral iridotomy (LPI) in primary angle closure suspect (PACS), using pre-treatment anterior segment optical coherence tomography (ASOCT) scans. A total of 116 eyes with PACS underwent LPI and time-domain ASOCT scans (temporal and nasal cuts) were performed before and 1 month after LPI. All the post-treatment scans were classified to one of the following categories: (a) both angles open, (b) one of two angles open and (c) both angles closed. After LPI, success is defined as one or more angles changed from close to open. In this proposed method, the pre and post-LPI ASOCT scans were registered at the corresponding angles based on similarities between the respective local descriptor features and random sample consensus technique was used to identify the largest consensus set of correspondences between the pre and post-LPI ASOCT scans. Subsequently, features such as correlation co-efficient (CC) and structural similarity index (SSIM) were extracted and correlated with the success of LPI. We included 116 eyes and 91 (78.44%) eyes fulfilled the criteria for success after LPI. Using the CC and SSIM index scores from this training set of ASOCT images, our algorithm showed that the success of LPI in eyes with narrow angles can be predicted with 89.7% accuracy, specificity of 95.2% and sensitivity of 36.4% based on pre-LPI ASOCT scans only. Using pre-LPI ASOCT scans, our proposed algorithm showed good accuracy in predicting the success of LPI for PACS eyes. This fully-automated algorithm could aid decision making in offering LPI as a prophylactic treatment for PACS.

[1]  D. Rueckert,et al.  Medical Image Registration , 2010 .

[2]  Weisi Lin,et al.  Cross-Examination for Angle-Closure Glaucoma Feature Detection , 2016, IEEE Journal of Biomedical and Health Informatics.

[3]  K. Sung,et al.  Baseline Anterior Segment Parameters Associated with the Long-term Outcome of Laser Peripheral Iridotomy , 2015, Current eye research.

[4]  Spaeth Gl,et al.  The normal development of the human anterior chamber angle: a new system of descriptive grading. , 1971 .

[5]  M. He,et al.  Association between baseline iris thickness and prophylactic laser peripheral iridotomy outcomes in primary angle-closure suspects. , 2014, Ophthalmology.

[6]  Lance Liu,et al.  Deconstructing the mechanisms of angle closure with anterior segment optical coherence tomography , 2011, Clinical & experimental ophthalmology.

[7]  Weisi Lin,et al.  Learning ECOC Code Matrix for Multiclass Classification with Application to Glaucoma Diagnosis , 2016, Journal of Medical Systems.

[8]  Weisi Lin,et al.  Reliable Feature Selection for Automated Angle Closure Glaucoma Mechanism Detection , 2015, Journal of Medical Systems.

[9]  Tin Aung,et al.  Angle closure glaucoma: a mechanistic review , 2011, Current opinion in ophthalmology.

[10]  Tin Aung,et al.  Associations of iris structural measurements in a Chinese population: the Singapore Chinese Eye Study. , 2013, Investigative ophthalmology & visual science.

[11]  T. Aung,et al.  Acute primary angle closure in an Asian population: long-term outcome of the fellow eye after prophylactic laser peripheral iridotomy. , 2000, Ophthalmology.

[12]  D. Friedman,et al.  Changes in Anterior Segment Morphology and Predictors of Angle Widening after Laser Iridotomy in South Indian Eyes. , 2016, Ophthalmology.

[13]  David J. Hawkes,et al.  A Comparison of 2D-3D Intensity-Based Registration and Feature-Based Registration for Neurointerventions , 2002, MICCAI.

[14]  T. Aung,et al.  Prevalence of glaucoma in rural Myanmar: the Meiktila Eye Study , 2007, British Journal of Ophthalmology.

[15]  Marcus Ang,et al.  Pretreatment anterior segment imaging during acute primary angle closure: insights into angle closure mechanisms in the acute phase. , 2014, Ophthalmology.

[16]  Fedor Guryanov,et al.  Fast medical image registration using bidirectional empirical mode decomposition , 2017, Signal Process. Image Commun..

[17]  Huang Cn [An epidemiologic study of glaucoma in Shunyi County, Beijing]. , 1989 .

[18]  P. Foster,et al.  Glaucoma in Mongolia. A population-based survey in Hövsgöl province, northern Mongolia. , 1996, Archives of ophthalmology.

[19]  Luc Van Gool,et al.  Speeded-Up Robust Features (SURF) , 2008, Comput. Vis. Image Underst..

[20]  Weisi Lin,et al.  Complex wavelet based quality assessment for AS-OCT images with application to Angle Closure Glaucoma diagnosis , 2016, Comput. Methods Programs Biomed..

[21]  H G SCHEIE,et al.  Width and pigmentation of the angle of the anterior chamber; a system of grading by gonioscopy. , 1957, A.M.A. archives of ophthalmology.

[22]  Mark A. Hall,et al.  Correlation-based Feature Selection for Machine Learning , 2003 .

[23]  Hervé Delingette,et al.  Sparse Bayesian registration of medical images for self‐tuning of parameters and spatially adaptive parametrization of displacements , 2017, Medical Image Anal..

[24]  R. Asokan,et al.  Is prophylactic laser peripheral iridotomy for primary angle closure suspects a risk factor for cataract progression? The Chennai Eye Disease Incidence Study , 2016, British Journal of Ophthalmology.

[25]  N. Congdon,et al.  Screening techniques for angle-closure glaucoma in rural Taiwan. , 2009, Acta ophthalmologica Scandinavica.

[26]  Kun Gao,et al.  A novel image registration approach via combining local features and geometric invariants , 2018, PloS one.

[27]  Lance Liu Mbbs Franzco Deconstructing the mechanisms of angle closure with anterior segment optical coherence tomography , 2011 .

[28]  D. Friedman,et al.  Determinants of angle width in Chinese Singaporeans. , 2012, Ophthalmology.

[29]  S. Loon,et al.  Laser iridotomy and the corneal endothelium: a systemic review , 2014, Acta ophthalmologica.

[30]  Paul J Foster,et al.  Ethnic differences in primary angle-closure glaucoma. , 2006, Current opinion in ophthalmology.

[31]  Nikos Paragios,et al.  Slice-to-volume medical image registration: a survey , 2017, Medical Image Anal..

[32]  J. Ouyang,et al.  [Multiple patterns of angle closure mechanisms in primary angle closure glaucoma in Chinese]. , 2000, [Zhonghua yan ke za zhi] Chinese journal of ophthalmology.

[33]  Ravi Thomas,et al.  Five-year risk of progression of primary angle closure to primary angle closure glaucoma: a population-based study. , 2003, Acta ophthalmologica Scandinavica.

[34]  P. Foster,et al.  The definition and classification of glaucoma in prevalence surveys , 2002, The British journal of ophthalmology.

[35]  Marcus Ang,et al.  Quantitative Assessment of Changes in Trabeculectomy Blebs After Laser Suture Lysis Using Anterior Segment Coherence Tomography , 2012, Journal of glaucoma.

[36]  M. He,et al.  Anatomic Predictors for Anterior Chamber Angle Opening After Laser Peripheral Iridotomy in Narrow Angle Eyes , 2012, Current eye research.

[37]  Robert C. Bolles,et al.  Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography , 1981, CACM.

[38]  N. Congdon,et al.  Issues in the epidemiology and population-based screening of primary angle-closure glaucoma. , 1992, Survey of ophthalmology.

[39]  P. Chew,et al.  What is the direct cost of treatment of acute primary angle closure glaucoma? The Singapore model , 2004, Clinical & experimental ophthalmology.

[40]  P. Stone,et al.  What is a systemic review? , 2002, Applied nursing research : ANR.

[41]  Dao-Yi Yu,et al.  Primary angle closure glaucoma: What we know and what we don’t know , 2017, Progress in Retinal and Eye Research.

[42]  G. Johnson,et al.  The Burden of Trachoma in the Rural Nile Delta of Egypt : a Survey of Menofiya Governorate The Epidemiology of Ocular Trauma in Singapore : Perspective from the Emergency Service of a Large Tertiary Hospital , 2005 .

[43]  Seungbong Han,et al.  Subclassification of Primary Angle Closure Using Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopic Parameters. , 2017, Ophthalmology.

[44]  K. Barton,et al.  Mechanism and management of angle closure in uveitis , 2015, Current opinion in ophthalmology.

[45]  Luc Van Gool,et al.  SURF: Speeded Up Robust Features , 2006, ECCV.

[46]  S. R. Krishnadas,et al.  Genome-wide association study identifies five new susceptibility loci for primary angle closure glaucoma , 2016, Nature Genetics.

[47]  J. Folch,et al.  Laser Peripheral Iridotomy in Primary Angle-Closure Suspects. Biometric and Gonioscopic Outcomes: The Liwan Eye Study , 2007 .

[48]  Roger Hitchings,et al.  Quantitative evaluation of anterior chamber parameters using anterior segment optical coherence tomography in primary angle closure mechanisms , 2012, Clinical & experimental ophthalmology.

[49]  Dong Yoon Kim,et al.  Residual anterior chamber angle closure in narrow-angle eyes following laser peripheral iridotomy: anterior segment optical coherence tomography quantitative study , 2011, Japanese Journal of Ophthalmology.

[50]  T. Aung,et al.  Changes in Japanese eyes after laser peripheral iridotomy: an anterior segment optical coherence tomography study , 2016, Clinical & experimental ophthalmology.

[51]  Weisi Lin,et al.  Automated anterior segment OCT image analysis for Angle Closure Glaucoma mechanisms classification , 2016, Comput. Methods Programs Biomed..

[52]  Fredrik Kahl,et al.  Überatlas: Robust Speed-Up of Feature-Based Registration and Multi-Atlas Segmentation , 2015, SCIA.