Radiograph-based femur morphing method

Many applications in orthopaedic surgery require the creation of personalised design models that can serve as the basis for navigation in computer aided surgery systems or be used to create a personalised model to perform structural analysis during pre-operative planning or post-operative follow-up. The paper introduces a method for developing a three-dimensional (3D) patient-specific model of a femur bone from an antero-posterior radiograph. A generic femur was employed and was altered on the basis of bone boundaries visible on radiographs. Morphological errors were evaluated against 3D models obtained from computed tomography (CT) scans. When only the antero-posterior radiograph was used, the average radius estimation error was 4.8 mm, the average percentage area estimation error was 14%, and the average percentage estimation error for inertial moments was 15%. If both the medial-lateral and the anterior-posterior radiographs were used, these errors were 2.0 mm, 5% and 7%, respectively. The procedure described can be profitably employed whenever CT scans are not available, such as during a retrospective analysis, or when CT scans cannot be justified because of X-ray exposure and cost considerations.

[1]  Jan Schmitt,et al.  Validation data for periprosthetic bone remodelling theories. , 2002, Journal of biomechanics.

[2]  P. Leyvraz,et al.  The morphology of the proximal femur. A three-dimensional radiographic analysis. , 1992, The Journal of bone and joint surgery. British volume.

[3]  G. Beaupré,et al.  Osseointegration of total hip arthroplasties: studies in humans and animals. , 1999, Journal of long-term effects of medical implants.

[4]  John C. Koch,et al.  The laws of bone architecture , 1917 .

[5]  H. Wissing,et al.  [Determining rotational errors of the femur by axial computerized tomography in comparison with clinical and conventional radiologic determination]. , 1993, Unfallchirurgie.

[6]  L Cristofolini,et al.  The 'standardized femur program' proposal for a reference geometry to be used for the creation of finite element models of the femur. , 1996, Journal of biomechanics.

[7]  H. Tullos,et al.  Effect of rotation on the radiographic appearance of the femoral canal. , 1994, The Journal of arthroplasty.

[8]  Julia Orlik,et al.  On the secondary stability of coated cementless hip replacement: parameters that affected interface strength. , 2003, Medical engineering & physics.

[9]  J M Bert,et al.  Custom total hip arthroplasty. , 1996, The Journal of arthroplasty.

[10]  Yan Kang,et al.  A new accurate and precise 3-D segmentation method for skeletal structures in volumetric CT data , 2003, IEEE Transactions on Medical Imaging.

[11]  R. Gustilo,et al.  Synthetic composite femurs for use in evaluation of torsional stability of cementless femoral prostheses , 1989 .

[12]  Banchong Mahaisavariya,et al.  Morphological study of the proximal femur: a new method of geometrical assessment using 3-dimensional reverse engineering. , 2002, Medical engineering & physics.

[13]  Wilhelm Roux,et al.  Gesammelte Abhandlungen über Entwickelungsmechanik der Organismen , 1895 .

[14]  W. Bargar,et al.  Shape the implant to the patient. A rationale for the use of custom-fit cementless total hip implants. , 1989, Clinical orthopaedics and related research.

[15]  P. Leyvraz,et al.  Three-dimensional morphology of the proximal femur. , 1997, The Journal of arthroplasty.

[16]  J. S. Milton,et al.  Introduction to Probability and Statistics: Principles and Applications for Engineering and the Comp , 1995 .

[17]  P. M. Calderale,et al.  FEM analysis of bone-implant system by using videodensitometric measurements , 1995 .

[18]  A. Amis,et al.  Correlation between pre-operative periprosthetic bone density and post-operative bone loss in THA can be explained by strain-adaptive remodelling. , 1999, Journal of biomechanics.

[19]  Wilhelm Roux,et al.  Gesammelte Abhandlungen über Entwickelungsmechanik der Organismen / von Wilhelm Roux. , 1895 .

[20]  D. Kohn,et al.  Femoral anatomy, computed tomography and computer-aided design of prosthetic implants , 2002, Archives of Orthopaedic and Trauma Surgery.

[21]  D R Sumner,et al.  Sensitivity of periprosthetic stress-shielding to load and the bone density-modulus relationship in subject-specific finite element models. , 2000, Journal of biomechanics.

[22]  C J Sutherland,et al.  Use of general purpose mechanical computer assisted engineering software in orthopaedic surgical planning: advantages and limitations. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[23]  H. Wissing,et al.  Rotationsfehlerbestimmung am Femur durch axiale Computertomographie im Vergleich zu klinischer und konventioneller radiologischer Bestimmung , 1993, Unfallchirurgie.

[24]  Cristina Bignardi,et al.  Biomechanical study of clinical results of orthopaedic implants by means of X-ray image observations , 1993 .

[25]  兼氏 歩 Three-dimensional morphological analysis of the proximal femoral canal,using computer-aided design system,in Japanese patients with osteoarthrosis of the hip , 2000 .

[26]  P S Walker,et al.  Accuracy of using radiographs for custom hip stem design. , 1996, The Journal of arthroplasty.

[27]  H. Tullos,et al.  The anatomic basis of femoral component design. , 1988, Clinical orthopaedics and related research.